AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
Power Linking
You can link up to 19 Ovation F-145WW products at 120 V, 34 products at 208 V, or 38 products at 230 V. Never exceed
this number. Power-linking cords can be purchased separately.
AC Plug
Replacing the Fuse
1.
Disconnect this product from power.
2.
Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Ovation F-145WW will work with a DMX controller using a 3- or 5-pin DMX data connection. A DMX Primer is
DMX Connection
The Ovation F-145WW uses a 3- or 5-pin DMX data connection for its DMX personalities:
1Ch: 8bit Dim
,
2Ch: 16bit
Dim
,
2Ch: 8bit Dim+Zoom
, and
6Ch: 16bit-Full
. See the User Manual for information about connecting and configuring
the product for DMX operation.
Master/Slave Connection
The Ovation F-145WW uses the DMX data connection for its Master/Slave mode. See the User Manual for information
about connect and configure the product for master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. The Ovation F-145WW supports RDM protocol that allows feedback to monitor temperature
and changes to
DMX Address
,
DMX Personality
,
Dimmer Mode
, and
LED Frequency
menu options. Download the
User Manual from
for more details.
Mounting
Before mounting this product, read the
. Use at least one mounting point per product. Make sure the
mounting clamps are capable of supporting the weight of the product. For our CHAUVET Professional line of mounting
clamps, go to
.
Mounting Diagram
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow/Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
Safety cable
Mounting clamp
Secure the safety cable
using the passageway on
the back of the product