background image

21

Maverick Storm 2 Profile User Manual Rev. 1

Operation

USB Update

To enable or disable software update using USB:

1. Go to the 

Settings

 main level.

2. Select the 

USB Update 

option.

3. Select 

NO

 (disables software update through USB) or 

YES

 (enables software update through 

USB).

Reset Function

To reset specific functions or the entire product:

1. Go to the 

Settings

 main level.

2. Select the 

Reset Function 

option.

3. Select the functions to reset, from 

Pan/Tilt

Iris/Prism

Color/CMY/Blade

Gobo/Gobo Rotate

Frost

, or 

All

.

4. Select 

NO

 (to cancel) or 

YES

 (to reset the selected functions).

Factory Reset

To reset the product to factory settings:

1. Go to the 

Settings

 main level.

2. Select the 

Factory Reset 

option.

3. Select 

NO

 (to cancel) or 

YES

 (to reset the product configuration).

Test Mode

Auto Test

To have the Maverick Storm 2 Profile automatically test all functions one after the other:

1. Go to the 

Test 

main level.

2. Select the 

Auto Test 

option.

Manual Test

To manually test an individual function of the Maverick Storm 2 Profile:

1. Go to the 

Test 

main level.

2. Select the 

Manual Test 

option.

3. Select a function to test, from 

Pan

Pan Fine

Tilt

Tilt Fine

P/T Speed

Dimmer

Dimmer Fine

Shutter

Virtual Shaking

Cyan

Magenta

Yellow

CTO

Color

Gobo

Gobo Rotate

Gobo 

Index

Gobo2

Blade1-1

Blade1-1 Fine

Blade1-2

Blade1-2 Fine

Blade2-1

Blade2-1 Fine

Blade2-2

Blade2-2 Fine

Blade3-1

Blade3-1 Fine

Blade3-2

Blade3-2 Fine

Blade4-1

Blade4-1 Fine

Blade4-2

Blade4-2 Fine

Blade Rotate

Blade. Rota Fine

Focus

Focus Fine

Focus Auto

Zoom

Zoom Fine

Prism

Prism Rotate

Iris

Frost

CMY Macro

CMY Macro 

Speed

, or 

Control

.

4. Increase or decrease the value of the selected function from 

0–255

 to test it.

System Information

The information section of the menu displays statistics and the current status of the product’s various 

functions. To view this information:

1. Go to the 

Information 

main level.

2. Select from the 

Fixture Information

Fan Information

Error Information

, or 

Channel 

Information

 options.

3. Use 

<UP> 

and 

<DOWN>

 to view all information.

See th

USB Software Update

 section for the detailed instructions on how to update the 

Maverick Storm 2 Profile software using a USB C connection.

Summary of Contents for MAVERICK STOM 2 PROFILE

Page 1: ...Model ID MAVERICKSTORM2PROFILE User Manual...

Page 2: ...tent for any other purpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 29...

Page 3: ...verview 4 Product Dimensions 5 3 Setup 6 AC Power 6 AC Plug 6 Fuse Replacement 6 Remote Device Management RDM 6 USB Software Update 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 Signal Connections...

Page 4: ...9 Display Backlight Timer 19 Fan Mode 20 Dimmer Curve 20 Pulse Width Modulation 20 LED Power 20 Minimum Zoom Focus 20 Preset Selection 20 Preset Synchronization 20 USB Update 21 Reset Function 21 Fact...

Page 5: ...ust accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void th...

Page 6: ...o the surrounding environment before connecting it to power Not for permanent outdoor installation in locations with extreme environmental conditions This includes but is not limited to Exposure to a...

Page 7: ...not start the product at lower temperatures The minimum ambient temperature is 22 F 30 C Do not operate the product at lower temperatures In the event of a serious operation problem stop using this pr...

Page 8: ...D yoke profile fixture including CMY CTO color mixing a 4 blade framing shutter system with rotation a color wheel 10 1 zoom a 5 facet prism wheel 1 rotating and 1 static gobo wheel integrated sun shi...

Page 9: ...Storm 2 Profile User Manual Rev 1 Introduction Product Dimensions 10 12 in 257 mm 14 43 in 366 6 mm 27 52 in 699 mm 18 62 in 473 mm 10 26 in 260 7 mm 15 28 in 388 mm 9 92 in 252 mm 13 7 in 348 mm 4 7...

Page 10: ...o menu map options USB Software Update The Maverick Storm 2 Profile allows for software update through USB using the built in USB port The product s USB port supports up to 32GB capacity and only work...

Page 11: ...t the structure onto which the product is being mounted can support the product s weight See the Technical Specifications for weight information When mounting the product overhead always use a safety...

Page 12: ...a 5 pin DMX connection or a WDMX connection For more information about DMX read the DMX primer at https www chauvetprofessional com wp content uploads 2016 06 DMX_Primer pdf Art Net Connection Art Ne...

Page 13: ...e Lock Screen option 3 Select NO control panel stays unlocked or YES locks control panel Passcode After being prompted to enter the passcode enter the numbers 0920 Technician Mode The technician mode...

Page 14: ...N WDMX Pan Reverse NO Normal pan YES Reversed pan Tilt Reverse NO Normal tilt YES Reversed tilt Screen Reverse NO Normal screen display YES Inverted screen display AUTO Automatic display orientation P...

Page 15: ...WER 64 255 Sets LED power Min Zoom Focus NO Enables disables Min Zoom Focus YES Preset Select PRESET A Recorded preset menu options PRESET B PRESET C Preset Sync NO Transfers recorded preset menu opti...

Page 16: ...2 2 Blade2 2 Fine Blade3 1 Blade3 1 Fine Blade3 2 Blade3 2 Fine Blade4 1 Blade4 1 Fine Blade4 2 Blade4 2 Fine Blade Rotate Blade Rota Fine Focus Focus Fine Focus Auto Zoom Zoom Fine Prism Prism Rotate...

Page 17: ...ows speed of each fan in rpm Base Fan1 2 Speed _ _ _ _ Error Information _ _ _ _ _ Shows any errors or No Error Channel Information Frequency 000 255 Shows all current values from input signals Pan Pa...

Page 18: ...ghest recommended starting address for Dmx Mode 48 CH is 465 Network Setup The Network Setup settings control the IP address subnet mask and universe of the product IP Mode To choose how the IP addres...

Page 19: ...ntrol 16 bit 5 5 Pan tilt speed 000 255 Fast to slow 6 6 Dimmer 000 255 0 100 7 Fine dimmer 000 255 Fine control 16 bit 7 8 Strobe 000 003 Off 004 007 On 008 076 Synchronized strobe slow to fast 077 1...

Page 20: ...slow 146 149 Stop 150 231 Counterclockwise rotation slow to fast 232 255 Alternating clockwise counterclockwise rotation short to long 17 Gobo 1 fine rotate 000 255 Fine control 16 bit 16 18 Gobo whee...

Page 21: ...otation 000 255 0 100 36 Fine blade rotation 000 255 Fine control 16 bit 26 37 Focus 000 255 0 100 38 Fine focus 000 255 Fine control 16 bit 39 Auto focus 000 010 No function 011 030 0 5 meters 031 05...

Page 22: ...gobo wheels 048 055 Blackout during pan tilt color wheel gobo wheels 056 095 No function 096 103 Pan reset 104 111 Tilt reset 112 119 Color wheel reset 120 127 Gobo wheels reset 128 135 No function 13...

Page 23: ...the Settings main level 2 Select the Tilt Angle option 3 Select from 270 260 180 180 or 090 90 Black out on Movement To set the product to black out while the pan tilt color wheel or gobo wheels are...

Page 24: ...control or YES focus adjusts depending on zoom setting Preset Selection To select a preset configuration of menu options 1 Go to the Settings main level 2 Select the Preset Select option 3 Select from...

Page 25: ...nction of the Maverick Storm 2 Profile 1 Go to the Test main level 2 Select the Manual Test option 3 Select a function to test from Pan Pan Fine Tilt Tilt Fine P T Speed Dimmer Dimmer Fine Shutter Vir...

Page 26: ...to ArtNet and the IP Mode to Static 2 Connect the product to a Windows computer with a network cable 3 On the computer set the first value of the IP address of the new network to match the first valu...

Page 27: ...tion Gobo Wheel Gobo Description 1 1 Pipes Poles 2 1 Dots 2 Cookie Cutter 2 Paperclip Party 3 This Way 3 Orbital 4 Fast Moves 4 Dirty Dirt 5 Laser Rays 5 Box Cutter 6 Limbo 6 Crazy Turns 7 Fractured M...

Page 28: ...utlet 2 Open the head cover by loosening the screws on the top cover 3 Separate the gobo holder away from the gobo wheel by pushing it toward the front of the moving head direction 1 in the diagram Be...

Page 29: ...rque Measurements To maintain the IP rating when reassembling the product use the given torque measurements for each of the following screws and bolts Screws inside feet 15 3 Kgf cm 13 3 lgb in Base s...

Page 30: ...Breaker F15 A 250 V F15 A 250 V F15 A 250 V F15 A 250 V F15 A 250 V Power I O U S Worldwide UK Europe Power Input Connector Seetronic Powerkon A Seetronic Powerkon A Power Cable plug Edison Local plug...

Page 31: ...ional com Chauvet U K Address Unit 1C Email UKtech chauvetlighting eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0...

Reviews: