Chauvet Professional COLORdash Par-Hex 12 QRG Quick Reference Manual Download Page 5

EN 

COLORdash™ Par-Hex 12 QRG 

Menu Options (cont.) 

Main Level 

Programming Levels 

Description 

Static (cont.) 

Fix C (cont.) 

RBWP 

Red/Blue/White/UV 

RAWP 

Red/Amber/White/UV 

GBAW 

Green/Blue/Amber/White 

GBAP 

Green/Blue/Amber/UV 

GBWP 

Green/Blue/White/UV 

GAWP 

Green/Amber/White/UV 

BAWP 

Blue/Amber/White/UV 

RGBAW 

Red/Green/Blue/Amber/White 

RGBAP 

Red/Green/Blue/Amber/UV 

RGBWP 

Red/Green/Blue/White/UV 

RGAWP 

Red/Green/Amber/White/UV 

RBAWP 

Red/Blue/Amber/White/UV 

GBAWP 

Green/Blue/Amber/White/UV 

RGBAWP 

Red/Green/Blue/Amber/White/UV 

Manu C 

Value 

0–255 

Combine red, green, blue, amber, white, 

and ultraviolet to make a custom color 

Dim Mode 

Off 

No dimmer 

DIM 1–3 

Dimming curves 

BackLite 

10S 

Turns off display backlight after 10 sec of 

inactivity 

20S 

Turns off display backlight after 20 sec of 

inactivity 

30S 

Turns off display backlight after 30 sec of 

inactivity 

On 

Display backlight always on  

Info 

Auto 

Test 

Turns on all LEDs in sequence for testing 

FixHours 

Shows total product hours 

Version 

Shows installed software version 

Address 

001–512 

Selects DMX address (highest channel 

restricted to personality chosen) 

Channel 

6 Ch 

6-channel: RGBAW+UV control 

8 Ch 

8-channel: RGBAW+UV control and 

dimmer 

12Ch 

12-channel: RGBAW+UV control, dimmer, 

strobe, color macro/white balance, auto 

programs, auto speed, dimmer speed 

13Ch 

13-channel: RGBAW+UV pixel control, 8-

bit, 16-bit, dimmer speed 

HSV 

HSV: hue, saturation, value control 

HSI 

HSI: hue, saturation, intensity control 

M&S Mode 

Master 

DMX mode 

Slave 

Slave mode 

White Balance 

Value 

125–255 

Sets red LED maximum value 

Sets green LED maximum value 

Sets blue LED maximum value 

Temp 

XX° 

Shows product’s temperature (°C) 

 

 

All manuals and user guides at all-guides.com

Summary of Contents for COLORdash Par-Hex 12 QRG

Page 1: ...Quick Reference Guide English EN Español ES Français FR All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ... and protected circuit ONLY use the hanging mounting bracket to carry this product In the event of a serious operating problem stop using immediately The maximum ambient temperature is 113 F 45 C Do not operate this product at higher temperatures Contact Outside the U S United Kingdom Ireland or Mexico contact your distributor to request support or return a product Visit www chauvetlighting com fo...

Page 3: ...e User Manual to connect and configure for Master Slave operation Mounting Product Mounting Diagram Control Panel Description Button Function MENU Exits from the current menu or function ENTER Enables the currently displayed menu or sets the currently selected value into the selected function UP Navigates upwards through the menu list and increases the numeric value when in a function DOWN Navigat...

Page 4: ...lue RGA Red Green Amber RGW Red Green White RGP Red Green UV RBA Red Blue Amber RBW Red Blue White RBP Red Blue UV RAW Red Amber White RAP Red Amber UV RWP Red White UV GBA Green Blue Amber GBW Green Blue White GBP Green Blue UV BAW Blue Amber White BAP Blue Amber UV AWP Amber White UV BWP Blue White UV GAW Green Amber White GAP Green Amber UV GWP Green White UV RGBA Red Green Blue Amber RGBW Red ...

Page 5: ...s off display backlight after 20 sec of inactivity 30S Turns off display backlight after 30 sec of inactivity On Display backlight always on Info Auto Test Turns on all LEDs in sequence for testing FixHours Shows total product hours Version Shows installed software version Address 001 512 Selects DMX address highest channel restricted to personality chosen Channel 6 Ch 6 channel RGBAW UV control 8...

Page 6: ...0 100 6 White 000 255 0 100 7 UV 000 255 0 100 8 Strobe 000 010 000 255 No function Slow to fast 13Ch Channel Function Value Percent Setting 1 Red H 8 bit 000 255 0 100 2 Red L 16 bit 000 255 0 100 3 Green H 8 bit 000 255 0 100 4 Green L 16 bit 000 255 0 100 5 Blue H 8 bit 000 255 0 100 6 Blue L 16 bit 000 255 0 100 7 Amber H 8 bit 000 255 0 100 8 Amber L 16 bit 000 255 0 100 9 White H 8 bit 000 2...

Page 7: ... 0 R 100 0 G 100 B 0 R 0 G 100 B 0 100 R 0 G 100 0 B 100 R 0 100 G 0 B 100 R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 A 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 10 Auto Programs 000 010 011 060 061 120 121 180 181 240 241 255 No function Auto program 1 Auto program 2 Auto program 3 Auto program 4 Auto program...

Page 8: ...d General Information Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO CHAUVET Mexico General Information Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexico C P 52000 Voice 52 728 285 5000 Technical Support Email ser...