EN
2
Ovation E-910FC IP QRG Rev. 11
QUICK REFERENCE GUIDE
What is Included
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
Power Linking
It is possible to link up to 5 Ovation E-910FC IP products at 100 VAC, 6 products at 120 V, 11 products at 208 V, or 12
products at 230 or 240 VAC. Never exceed this number. Power linking cords can be purchased separately.
AC Plug
DMX Linking
The Ovation E-910FC IP will work with a DMX controller using a 5-pin DMX serial connection. A DMX Primer is available
DMX Connection
The Ovation E-910FC IP uses a 5-pin DMX data connection for its DMX personalities:
1Ch
,
4Ch
,
6Ch
,
8Ch
,
11Ch
,
13Ch
,
14Ch
,
17Ch
, and
HSV
. See the User Manual for information about connecting and configuring the product for DMX
operation.
Master/Slave Connection
The Ovation E-910FC IP uses the DMX data connection for its master/slave mode. See the User Manual for information
about how to connect and configure the product for master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers
have this capability. The Ovation E-910FC IP supports RDM protocol that allows feedback to make changes to menu
map options. Download the User Manual from
for more details.
•
Ovation E-910FC IP
•
Seetronic Powerkon IP65 power cord
•
Soft focus filter
•
Quick Reference Guide
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow/Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect
the product from power via breaker or by unplugging it.
•
When using this product in an outdoor IP65-type environment, be sure to use IP65 (or higher) rated power
cables and secure unused ports with attached IP65 covers.
When using this product in an outdoor IP65-type environment, be sure to use IP65-rated (or higher)
data cables and secure unused ports with attached IP65 covers.
!
!