charnwood
INSTALLATION INSTRUCTIONS
SLX
4 5
MULTI-FUEL
15
fluepipe from the stove will protrude a small amount through the
hole in the register plate, and will be sealed in position. This is shown
in Fig.11.
THERMOSTAT
Before lighting the fire check the cold setting distance of the
thermostat.
With the control knob at the minimum setting the flap should be just
closed as shown in Fig. 12. To adjust the distance slacken the locking
nut and adjust as necessary. When set correctly re-tighten the locking
nut. Ensure that the flap opens and closes freely as the knob is
turned.
ASSEMBLY
Fit the side panels and hood onto the appliance. Instructions for this
are enclosed with the panel pack. Replace any internal parts
previously removed.
PRE LIGHTING CHECK
Before initial lighting check the following points:
1. The bottom grate bars must all be fitted and should move freely
and easily when the riddling mechanism is operated.
2. The plates round the sides and back of the grate must be in
position and sitting correctly.
3. The throat plate must be fitted in the roof of the appliance and
should be pushed back so that it touches the knee of the boiler.
COMMISSIONING
On completion of the installation and after allowing a suitable period
of time for the fire cement and mortar to dry out, the fire should be
lit and checked to ensure that smoke and fumes are taken from the
appliance up the chimney and emitted safely. Also check all joints and
seals.
The central heating pump should be adjusted to give the correct
water flow against the circuit resistance and the system should be
correctly balanced.
On completion of the installation and commissioning please leave the
operating instructions with the customer and advise on the use of the
appliance and any controls on the system.
Fig. 12. Thermostat Setting
Thermostat Flap
Locking Nut
Flap Just Closed With
Knob Set To Minimum