Fig. 11. Flue Blanking Plate
PRE LIGHTING CHECK
Ensure that upper throat plate (Skye 7, top flue outlet connection
only) and the throat plate is fitted in the roof of the appliance. The
location and positioning of the throat plate is shown in Fig. 6.
Check that the front fence is fitted correctly and that the door closes
properly.
COMMISSIONING
On completion of the installation allow a suitable period of time for
the fire cement and mortar to dry out before lighting the fire. Make
a layer of ash or sand on the base of the stove before lighting. Check
to ensure that smoke and fumes are taken from the appliance up
the chimney and emitted safely. Also check all joints and seals. On
completion of the installation and commissioning please leave the
operating instructions with the customer and advise them on the use
of the appliance.
Flue draught can be checked by removing the bolt that is located
to the right of the rear flue exit behind the rear panel (Skye 5) or
removing the bolt underneath the front left hand side (Skye 7)
FITTING THE REAR HEAT SHIELD
The Skye is supplied with an optional rear heat shield. When fitted to
the back of the stove it will reduce the rear distance to combustibles:
Skye 5:
90mm
Skye 7:
100mm
To fit the optional rear heat shield, loosen the button head allen
screws and slide the heat shield on so that the slots on the back of
the heat shield fit over the screws. (fig. 12)
Fig. 12. Fitting the optional rear heat shield.
CAA AND SMOKE CONTROL
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or
part of the district of the authority to be a smoke control area. It
is an offence to emit smoke from a chimney of a building, from a
furnace or from any fixed boiler if located in a designated smoke
control area. It is also an offence to acquire an “unauthorised fuel”
for use within a smoke control area unless it is used in an “exempt”
appliance (“exempted” from the controls which generally apply in
the smoke control area).
In England appliances are exempted by publication on a list by the
Secretary of State in accordance with changes made to sections 20
and 21 of the Clean Air Act 1993 by section 15 of the Deregulation
Act 2015. Similarly in Scotland appliances are exempted bypublication
on a list by Scottish Ministers under section 50 of the Regulatory
Reform (Scotland) Act 2014.
In Northern Ireland appliances are exempted by publication on
a list by the Department of Agriculture, Environment and Rural
Affairs under Section 16 of the Environmental Better regulation Act
(Northern Ireland) 2016.
In Wales appliances are exempted by regulations made by Welsh
Ministers.
Further information on the requirements of the Clean Air Act can be
found here: https://www.gov.uk/smoke-control-area-rules
Back of Stove
Blanking Plate
Glass Fibre Webbing
Blanking Plate
Seal Blanking Plate with
Glass Fibre Webbing
Clamping plate finishes flush
with the inside face of the
firebox top and bottom.
Inside of Stove
Clamping Plate
M8 Nut
Slots in position
Optional rear heatshield
INSTALLATION INSTRUCTIONS