background image

Operating & Installation Instructions

 

®

Summary of Contents for Skye 5

Page 1: ...Operating Installation Instructions ...

Page 2: ......

Page 3: ... need further help 9 INSTALLATION INSTRUCTIONS Health Safety Precautions CO Alarms Specification Chimney Hearth Fire Surround 11 Connection to Flues 12 Soot Doors 12 Pre Lighting Check 12 Commissioning 13 15 Multi Grate 5 Riddling 6 Controlling The Fire Unpacking The Stove 10 10 10 10 10 11 Optional Rear Heat Shield 13 Clean Air Act Information 13 Certification 14 Dimensions Skye 5 Skye 5 low Skye...

Page 4: ...does not protrude beyond retainer d b Glass Wipewith damp lint freecloth removedwithaproprietarystoveglasscleaneror ceramichob cleaner Any stubborn deposits on the glass may be Throat plate Takedownonceamonth andclean Sweepsootydeposits intofire Chimney Havechimneyswept twiceayear Chimneycanbeswept throughstove Servicing Stoveshouldbeservicedbyaprofessionalat least onceayear MAINTENANCE AND CLEANI...

Page 5: ... only be carried out once or twice a week Congratulations on becoming the owner of a Charnwood Skye Stove Your stove has been approved in smoke control areas to burn wood logs if it is used in accordance with these instructions It is very important that you read and understand these instructions before using the stove FUEL Before lighting the stove check with the installer that the work and checks...

Page 6: ...nce the fire is up to temperature the airwash system will begin to work so allow the fire to become hot before adjusting the air control to the required setting During the lighting period do not leave the stove unattended Do not leave the door open except as directed above to avoid excessive smoke When relighting the stove leave the ash on the base if burning wood unless it is becoming too deep in...

Page 7: ...rrying handle to prevent it falling off the tool Please avoid emptying hot ash into plastic liners or bins The Ashpan should be emptied regularly before it becomes too full Never allow the ash to accumulate in the ashpan so that it comes in contact with the underside of the grate as this will seriously damage the grate bars To make ash removal easier there are ash carriers available These may be p...

Page 8: ...efore lighting It is important that the throat plate and all the stove flueways are kept clean in order to prevent potentially dangerous fume emission They should be cleaned at least monthly and more frequently if necessary It is necessary to let the fire out to carry out these operations To remove the throat plate first remove the fuel retainer item e page 5 and one side plate to allow enough roo...

Page 9: ...ted this appliance will not emit fumes Occasional fumes from de ashing and re fuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely dispose of the fuel from the appliance ...

Page 10: ...or use in a shared flue system 10 INSTALLATION INSTRUCTIONS In addition to these instructions the requirements of BS 8303 and BSEN 15287 1 2007 must be fulfilled Local Authority Bylaws and Building Regulations including those referring to national and European Standards regarding the installation of Solid Fuel burning appliances flues and chimneys must also be observed CO ALARMS Building regulatio...

Page 11: ...s adequately fireproofed in accordance with local building regulations The hearth must be of fireproof material and at least 12mm 1 2in thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state that the hearth must extend in front of the stove by at least 225mm 9 in and to the sides of the stove by at ...

Page 12: ...gs on the firebox as shown in Fig 11 Ensure that the clamping plate does not prevent the throat plate from seating correctly All flue connections must be well sealed It is possible to pass a 16 inch diameter sweeps brush through the appliance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept The optional vertical rear flue connector do...

Page 13: ...ted smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by se...

Page 14: ...UEL Space heating thermal output 5kW 5kW 5kW 5kW Emission of CO in combustion products 0 06 0 10 0 06 0 10 Mean flue gas temperature 239 C 247 C 239 C 247 C Energy efficiency 86 82 86 82 3 Particles mg m n 25 13 25 13 Minimum distance to combustible materials with Insulated flue Side Rear Minimum distance to combustible materials with Insulated flue rear heat shield Side Rear 300mm 270mm 300mm 90m...

Page 15: ...15 423 301 498 122 81 808 509 160 390 833 623 509 390 648 160 63 249 709 63 64 524 Standard Model Low Model Optional vertical rear flue adaptor To suit 125mm 5 flue pipe DIMENSIONS mm CHARNWOOD SKYE 5 ...

Page 16: ...op 22 008 FFM081 Circlip 59 002 BU040 Door Hinge Bracket 23 002 BU009 Cast Top 60 008 FFW024 M8 Brass Washer 24 010 BU012 Blanking Plate 61 004 BU039 Door Hinge Shim 25 008 BU004 Flue Fixing Rope Seal 62 DY24 Spacer 26 008 BU021 Self Adhesive Webbing 63 012 BU011 Serial No Label 27 010 BU019 Blanking Plate Retainer 64 001 BU010 Firebox 28 010 EY51 Clamping Plate 65 004 BU081 Rear Heatshield 29 010...

Page 17: ...Inlet Spigot 22 002 BU098 Riddler Spigot 59 008 FFS067 Defra Stop 23 008 FFM081 Circlip 60 002 BU040 Door Hinge Bracket 24 002 BU009 Cast Top 61 008 FFW024 M8 Brass Washer 25 010 BU012 Blanking Plate 62 004 BU039 Door Hinge Shim 26 008 BU004 Flue Fixing Rope Seal 63 DY24 Spacer 27 008 BU021 Self Adhesive Webbing 64 012 BUL011 Serial No Label 28 010 BU019 Blanking Plate Retainer 65 001 BUL010 Fireb...

Page 18: ......

Page 19: ......

Page 20: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r ...

Reviews: