Parts List

Item

Part No.

Description

1*

008/AY62S

Door Seal Set Inc. Adhesive

27

008/BW39/S

Hinge Pin Set

2*

008/FW29

Door Seal Adhesive

28

002/AY28

Hinge Post

3

002/CG20

Bottom Grate Bar

28a

002/PY24

Hinge Post

4

002/CG20S10

Set of Grate Bars (10)

29

008/AY37

Air Control Knob

5

002/CY15

Side Fire Plate

30

010/AY34

Riddling/Ashpan Tool

6

002/AY16

Back Fire Plate

31

002/AY27

Riddler Knob

7

004/BY24

Ash Shedding Plate

32

004/AY21

Air Bypass Slide

8

006/AY18

Glass (Inc Seal)

33

004/AY22-1P

Primary Air Inlet Flap

9*

008/AY45

Glass Seal 

34

004/AY22-1S

Secondary/Bypass Air Inlet Flap

10

004/KV23

Glass Retainer

35

004/AY24-02

Flap Mounting Rod (Inc. Fixings)

11**

011/AY29S

Set of Fire Bricks (4)

36

004/BY23-07

Air Control Rod

12**

010/AY31

Throat Plate

37

004/AY23

Actuator Assembly

13

011/AY48S

Set of Fire Bricks (4)

38

008/AY39

Upper Quattro Box Gasket

14

004/XV30

Brick Retainer

39

010/AY20

Upper Quattro Box

15

004/LV24

Rear Brick Joining Bracket 

40

010/AY19

Lower Quattro Box

16

010/AY47

Throat Plate

41#

002/AY01/A

Left Hand Door Assembly

17

008/AY26S

Set of Air Inlet Flap Pads

42#

002/AY02/A

Right Hand Door Assembly

18

012/AY33

Mover Bar

43#

001/AY10

Firebox (Island I)

19

002/AY30

Carrier Bar

44

012/TW09

Blanking Plate

20

012/AY13

Idler Rod

45

010/AY51

Clamping Plate

21

012/AY15

Riddler Rod 

46

002/CH12B

Flue Collar

22

004/AY17

Ashpan

47

008/NV38

Flue Fixing Rope Seal

23

002/AY07B

Front Firebar

48

012/AY11

Serial No. Label

23a

002/AY08

Deepening Bar

49#

010/TW33

Vert. Rear Flue Connector (Opt'l Extra)

24

008/KV16

R.H. Door Handle

50*

010/EW51

Ash Carrier (Optional Extra)

25

002/AY14

Door Catch Cam

51*

010/AY83

Smoke Reducing Kit

26

008/KV13

L.H. Door Knob

52*

010/AY52A

External Air Manifold Kit

Item

Part No.

Description

* These items are not shown on the drawing.

** These items are only used on models up to Serial No. 2403.

# Please specify colour when ordering.

To obtain spare parts please contact your local stockist giving Model, Part 
No. and Description. In case of difficulty contact the manufacturer at the 
address shown.
This drawing is for identification purposes only.

13

15

43

44

42

8

31

7

5

24

25

41

26

29

36

37

39

38

47

22

18

20

6

3

4

32

33

17

19

34

17

21

10

35

27

49

46

8

30

19

45

48

40

13

13

13

16

14

28a

28

28 Up to Serial No 2865

28a From 2866 onwards

11

12

Brick & Throatplate arrangement

 

up to Serial No. 2403

15

®

charnwood

T:+44  (0)1983  537799  •  F:+44  (0)1983  537788  •  [email protected]  •  WWW.CHARNWOOD.COM 

  BISHOPS  WAY,  NEWPORT,  ISLE  OF  WIGHT    PO30  5WS,  UNITED  KINGDOM

 

 

ISLAND I PARTS LIST

®

charnwood

I

I S L A N D

III

II

23

23a

Summary of Contents for Island 1

Page 1: ...Operating Installation Instructions charnwood I I S L A N D III II ...

Page 2: ......

Page 3: ...g 6 Trouble Shooting 7 If you need Further help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 Specification 9 Chimney 9 Hearth Fire Surround 10 Island I Dimensions 12 Lighting 5 Connection to Flues 10 Soot Doors 11 Pre Lighting Check 11 Commissioning 11 Island II Dimensions 13 Island III Dimensions 14 Parts Lists 15 17 Certification 18 I I S L A N D III II Ref Island I II III 06 13 Issue...

Page 4: ...reguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Do not use an aerosol spray on or near the stove when it is alight There is a risk of explosion or flash ignition of the spray FUEL This stove is intended primarily for burning wood Only dry well seasoned wood should be burnt on this appliance as burning wet unseas...

Page 5: ...o evaporate When relighting the stove riddle slightly and then empty the ashpan CONTROLLING THE FIRE The fire is controlled by the single air control knob shown in Fig 1 Pull the knob out to make the fire burn faster push it in to make the fire burn slower TM This unique QuattroFlow air control provides carefully balanced primary secondary tertiary and bypass air to enable optimum burning conditio...

Page 6: ...ng well After long periods where the fire has been out of use the chimney and appliance flueways should be cleaned before lighting Door Seals For the fire to operate correctly it is important that the door seals are in good condition Check that they do not become worn or frayed and replace them when necessary Servicing It is recommended that the fire is serviced once a year to keep it in first cla...

Page 7: ... airwash air to enter the stove even when the air control is closed This can be adjusted to help with keeping the glass clean when the fire is slumbering It is always more difficult to keep the glass clean when running the stove very slowly for long periods Check that all flue connections and the blanking plate are well sealed It is also important that the chimney draw is sufficient when the chimn...

Page 8: ...mney and flueways should then be cleaned If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately After a chimney fire the chimney should be carefully examined for any damage Expert advice should be sought if necessary IF YOU NEED FURTHER HELP If you need further help with your Charnwood Island then your Installer will be able to provide...

Page 9: ... in which the appliance is installed to provide combustion air The has 5kW output and therefore a permanent air vent is not normally required The combustion air supply for Island 2 3 must be via a 2 permanently open vent Minimum free areas are 16 5cm 2 2 2 2 5 in 38 5cm 6 in 150 x 150mm internal square For the Island 3 be less than 175mm 7 inches internal diameter or 175 x 175mm internal square If...

Page 10: ...antelpiece to protect it In order for the fire to operate correctly there must be an air gap behind the appliance of at least 40mm but be aware that this distance will need to be greater in some cases to meet Building Regulation requirements CONNECTIONS TO FLUES There are several ways of connecting the stove to the flue These are illustrated in figures 4 to 7 If a top flue connection as shown in F...

Page 11: ... The bottom grate bars must all be fitted and should move freely and easilywhentheriddlingmechanism isoperated 2 The plates round the sides and back of the grate must be in position andsittingcorrectly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The method of location andpositioningof thethroat plateissh...

Page 12: ...W BACK VIEW TOP VIEW 533 670 551 331 Max dim with door open 601 Optional Vertical Rear Flue Adapter 88 410 132 163 465 143 634 554 579 99 355 439 155 Optional External Air Manifold 464 87 554 726 379 439 190 178 555 514 760 554 705 299 225 213 420 100 590 Flue outlet to suit 150mm 6 flue pipe ISLAND I DIMENSIONS ...

Page 13: ... BACK VIEW TOP VIEW 605 622 331 Max dim with door open 639 Optional Vertical Rear Flue Adapter 132 421 160 476 88 143 674 624 619 99 155 365 447 Optional External Air Manifold 87 504 765 624 710 875 624 820 584 447 190 393 48 179 595 301 295 289 451 120 705 Flue outlet to suit 150mm 6 flue pipe ISLAND II DIMENSIONS ...

Page 14: ...S L A N D charnwood FRONT VIEW SIDE VIEW BACK VIEW HIGH LEG STORE STAND STANDARD LEG TOP VIEW Max dim with doors open 705 Optional Vertical Rear Flue Adapter 105 452 533 171 147 186 713 754 763 732 108 845 754 795 750 945 995 714 484 196 400 484 428 190 400 48 335 309 Optional External air manifold 588 107 670 189 820 339 Flue outlet to suit 175mm 7 flue pipe ...

Page 15: ...and I 19 002 AY30 Carrier Bar 44 012 TW09 Blanking Plate 20 012 AY13 Idler Rod 45 010 AY51 Clamping Plate 21 012 AY15 Riddler Rod 46 002 CH12B Flue Collar 22 004 AY17 Ashpan 47 008 NV38 Flue Fixing Rope Seal 23 002 AY07B Front Firebar 48 012 AY11 Serial No Label 23a 002 AY08 Deepening Bar 49 010 TW33 Vert Rear Flue Connector Opt l Extra 24 008 KV16 R H Door Handle 50 010 EW51 Ash Carrier Optional ...

Page 16: ...e 19 002 BY30 Carrier Bar 45 010 AY51 Clamping Plate 20 012 AY13 Idler Rod 46 002 CH12B Flue Collar 21 012 AY15 Riddler Rod 47 008 NV38 Flue Fixing Rope Seal 22 004 BY17 Ashpan 48 012 BY11 Serial No Label 23 002 BY07B Front Firebar 49 010 TW33 Vert Rear Flue Connector Opt l Extra 23a 002 BY08 Deepening Bar 50 010 BW51 Ash Carrier Optional Extra 24 008 KV16 R H Door Handle 51 010 BY83 Smoke Reducin...

Page 17: ...ler Rod 44 001 CY10 Firebox Island III 21 004 CY17L Ashpan L H 45 010 CY37 Blanking Plate 22 004 CY17R Ashpan R H 46 010 CY61 Clamping Plate 23 002 CY07C Front Firebar 47 002 CY45 Flue Collar 23a 002 CY08C Deepening Bar 48 008 CY38 Flue Fixing Rope Seal 24 008 KV16 R H Door Handle 49 012 CY11 Serial No Label 25 002 AY14 Door Catch Cam 50 010 CY34 Vert Rear Flue Connector Opt l Extra 26 008 KV13 L ...

Page 18: ... EFFICIENCY FUEL TYPES A Division of A J Wells Sons Limited Registered in England No 03809371 10 charnwood I S L A N D I III II Island I AY50 CPD 2010 450mm 600mm 0 29 254 C 5 0kW 77 9 Wood Logs Island II BY50 CPD 2006 450mm 600mm 0 50 290 C 8 0kW 78 0 Wood Logs Island III CY44 CPD 2006 600mm 600mm 0 30 365 C 12 0kW 76 4 Wood Logs Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS...

Page 19: ......

Page 20: ...d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r REF ISLAND I II III 06 13 ISSUE L ...