Summary of Contents for Aire

Page 1: ... Operating Installation Instructions AUSTRALIA ...

Page 2: ......

Page 3: ...CTIONS 9 CONNECTIONS TO FLUES 10 PRE LIGHTING CHECK 10 COMMISSIONING 10 COOKING PLATE 10 CLEARANCES 11 STANDARD HEARTH DIMENSIONS 12 CORNER HEARTH DIMENSIONS 13 AIRE 3 DIMENSIONS 14 AIRE 7 DIMENSIONS 15 AIRE 3 LOW PARTS LIST 16 AIRE 3 STORE STAND PARTS LIST 17 AIRE 7 LOW PARTS LIST 18 AIRE 7 STORE STAND PARTS LIST 19 FLUE CLEARANCES DIAGRAM 20 STANDARD DEFAULT TRIPLE SKIN FLUE KIT 21 INSULATED ROO...

Page 4: ...y deposits into fire FLUE Have flue swept anually Flue can be swept through stove SERVICING Stove should be serviced by a professional at least once a year Suitable fuels for your Charnwood Wood logs Unsuitable fuels Petroleum coke Liquid fuel Household waste Coal singles Small nuts or coal dust Wet or unseasoned wood Smokeless mineral fuel LIGHTING AND CONTROLLING THE FIRE Add kindling and paper ...

Page 5: ...NTEE This stove is not designed to burn household waste LIGHTING On initial lighting the stove may smoke and give off an odour as the silicon paint with which the firebox is painted reacts to the heat This is normal and will cease after a short time but meanwhile the room should be kept well ventilated At first only light a small fire and burn it slowly for two hours to allow any residual moisture...

Page 6: ...e experimentation may be necessary to find the setting most suitable for the type of fuel being used and the draw on the flue MAINTENANCE Cleaning The stove is finished with a high temperature paint which will withstand the temperatures encountered in normal use This may be cleaned with a damp lint free cloth when the stove is cold Should re painting become necessary high temperature paints are av...

Page 7: ...possible that the higher flue gas temperature from a stove may loosen soot deposits with the consequent risk of flue blockage It is therefore recommended that the flue be swept a second time within a month of regular use after installation Your Charnwood flue should be swept at least twice a year Where the top outlet or vertical rear flue connector is used it will generally be possible to sweep th...

Page 8: ...ng immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely dispose of the fuel from the appliance c Check for flue or flue blockage and clean if required d Do not attempt to re light the fire until cause of fuming has been identified if necessary seek professional advice The most common cause of fume emission is a f...

Page 9: ...th the alarm manufacturer s instructions SPECIFICATION FLUE In order for the appliance to perform satisfactorily the flue must give sufficient draw when warm minimum of 12pa 0 05 wg The height of the flue must comply with local building regulation requirements The internal dimensions of the chimney MUST NOT BE LESS THAN 125 mm 5 Aire 3 150mm 6 Aire 7 The listed flue s construction and installation...

Page 10: ...utlet The seal for the top outlet is a 155mm dia ring of rope seal The seal for the rear outlet is a length of adhesive backed fibre webbing supplied with instructions ref TIS093 This is applied to the flue collar or the Vertical Rear Flue adapter for rear outlet installations If a Vertical Rear Flue adapter is used on the Aire 3 then the 010 AA081 spacer plate is required this is supplied with th...

Page 11: ... COMBUSTIBLE WALLS CORNER POSITION Standard Clearance A 75mm B 210mm C 325mm D 512mm AIRE 3 LOW STORE STAND AIRE 7 LOW STORE STAND Standard Clearance A 100mm B 276mm C 425mm D 688mm Corner Clearance A 200mm B 393mm Corner Clearance A 250mm B 526mm ...

Page 12: ...mm MIN DIMENSIONS TO WALL A 1015mm B 820mm C 438mm D 250mm E 100mm TO WALL MIN DIMENSIONS TO WALL A 1151mm B 675mm C 300mm D 200mm E 381mm MIN DIMENSIONS TO WALL A 1512mm B 820mm C 490mm D 250mm E 458mm MIN DIMENSIONS TO WALL A 1460mm B 820mm C 438mm D 250mm E 458mm VERTICAL REAR FLUE ADAPTOR VERTICAL REAR FLUE ADAPTOR VERTICAL REAR FLUE ADAPTOR VERTICAL REAR FLUE ADAPTOR AIRE 3 LOW STORE STAND AI...

Page 13: ...m dimensions to wall VERTICAL REAR FLUE ADAPTOR CORNER HEARTH A 675mm B 393mm C 300mm CORNER HEARTH A 820mm B 526mm C 490mm CORNER HEARTH A 820mm B 526mm C 438mm WITH VERTICAL REAR FLUE ADAPTOR A 675mm B 393mm C 300mm D 381mm WITH VERTICAL REAR FLUE ADAPTOR A 820mm B 526mm C 490mm D 458mm WITH VERTICAL REAR FLUE ADAPTOR A 820mm B 526mm C 438mm D 458mm AIRE 3 LOW STORE STAND AIRE 7 LOW AIRE 7 STORE...

Page 14: ...9 384 610 344 126 626 65 0 168 504 500 384 306 516 65 61 394 FRONT SIDE REAR To suit 125mm 5 flue pipe OPTIONAL VERTICAL REAR FLUE ADAPTOR With bolted on flue collar spacer plate WITH HEATSHIELD WITHOUT HEATSHIELD STORE STAND LOW PLAN VIEW ...

Page 15: ...E REAR PLAN VIEW To suit 150mm 6 flue pipe OPTIONAL VERTICAL REAR FLUE ADAPTOR With bolted on flue collar WITH HEATSHIELD WITHOUT HEATSHIELD STORE STAND LOW 755 535 428 136 774 600 535 390 619 427 96 468 251 176 79 645 231 79 490 72 ...

Page 16: ...te 10 010 EY51 Clamping Plate 11 008 EY38 Flue Fixing Rope Seal 12 002 PV12B Flue Collar 13 004 BR021 Hinge Shim 14 002 BR020 Hinge 15 008 ST068 2 Hinge Pin Set 16 003 AA001A Door Assembly 17 003 AB012A Door Handle 18 003 AB055A Latch Receiver 19 008 AA110 Air Control Gasket 20 010 AA114 Air Control Plate 21 008 BR045 Lower Airbox Gasket 22 004 AA115 Slider 23 004 BR015 Clicker Retainer Plate 24 0...

Page 17: ...late 11 008 EY38 Flue Fixing Rope Seal 12 002 PV12B Flue Collar 13 004 BR021 Hinge Shim 14 002 BR020 Hinge 15 008 ST068 2 Hinge Pin Set 16 003 AA001A Door Assembly 17 003 AB012A Door Handle 18 003 AB055A Latch Receiver 19 008 AA110 Air Control Gasket 20 010 AA114 Air Control Plate 21 008 BR045 Lower Airbox Gasket 22 004 AA115 Slider 23 004 BR015 Clicker Retainer Plate 24 008 ES36 01 Brass Ball Cat...

Page 18: ...9 004 XV30 Brick Bracket 10 012 TW09 Blanking Plate 11 010 AY51 Clamping Plate 12 008 NV38 Flue Fixing Rope Seal 13 002 CH12B Flue Collar 14 002 BR020 Hinge 15 008 ST068 2 Hinge Pin Set 16 003 AC001A Door Assembly 17 003 AB012A Door Handle 18 003 AB055A Latch Reciever 19 008 AB110 Air Control Gasket 20 010 AC130 Air Control Plate 21 004 AC115 Slider 22 010 AC077 Base Cover Plate 23 010 AC078 Base ...

Page 19: ...012 TW09 Blanking Plate 11 010 AY51 Clamping Plate 12 008 NV38 Flue Fixing Rope Seal 13 002 CH12B Flue Collar 14 002 BR020 Hinge 15 008 ST068 2 Hinge Pin Set 16 003 AC001A Door Assembly 17 003 AB012A Door Handle 18 003 AB055A Latch Reciever 19 008 AB110 Air Control Gasket 20 010 AC130 Air Control Plate 21 004 AC115 Slider 22 010 AC077 Base Cover Plate 23 010 AC078 Base Blanking Plate 24 010 AC043 ...

Page 20: ... top Increase from 1000 min until clear within 3000 of flue top DIMENSIONS IN MILLIMETRES Summary of minimum height of flue sytem exit requirements from AS NZS 2918 2018 More than 3000 More than 3000 600 min 600 min 3000 Any nearby structure Increase as necessary until nothing within 6000 of flue top ...

Page 21: ...21 150 1000 1000 1000 1000 25 600 Cowl Triple skin flue Flashing Optional Decorative Flue Solid OR Mesh Ceiling Ring Dropbox STANDARD DEFAULT TRIPLE SKIN FLUE KIT ...

Page 22: ...22 INSULATED ROOM SEAL FLUE KIT 185 1000 1000 1000 25 50 Single skin flue Room sealed flue adaptor Ceiling ring Heatshield Starter length flue Cowl Room sealed flue with locking band STANDARD FLUE KIT ...

Page 23: ...23 INSULATED ROOM SEAL FLUE KIT FULLY SEALED FLUE KIT 1000 1000 1000 1000 25 50 Cowl Ceiling ring Heatshield Starter length flue Room sealed flue with locking band ...

Page 24: ...mm clearance to any timber to the side and underneath Min 470 Max 620 Cowl Adjustable wall bracket Cleaning access Wall Plate INSULATED ROOM SEAL FLUE KIT REAR FLUE KIT Room sealed flue with locking band Room sealed flue with locking band Room sealed flue adaptor 90 degree tee with cap Wall plate gal Ceiling ring Roof support brace ...

Page 25: ...25 COMPLIANCE DATA AIRE 3 COMPLIANCE DATA AIRE 7 COMPLIANCE DATA Compliance plate riveted onto rear heatshield Aire 3 Aire 7 ...

Page 26: ...and must be accompanied by proof of purchase Nothing in this guarantee shall affect your statutory rights EXCLUSIONS AND LIMITATIONS This Guarantee does not cover the following Charnwood will not be liable for any consequential loss or incidental loss damage or injury however caused This guarantee will become void if the appliance is not installed by a suitably qualified and is not installed in ac...

Page 27: ......

Page 28: ...your premier dealer ...

Reviews: