![Charnwood Aire 5 low Operating & Installation Instructions Manual Download Page 11](http://html1.mh-extra.com/html/charnwood/aire-5-low/aire-5-low_operating-and-installation-instructions-manual_2591950011.webp)
11
®
INSTALLATION INSTRUCTIONS
The stove comes with the blanking plate (fig. 9) fitted to the top
flue outlet. The seal for the top outlet is a 155mm dia ring of rope
seal. The seal for the rear outlet is a length of adhesive backed
fibre webbing supplied with instructions ref: TIS093. This is applied
to the flue collar or the Vertical Rear Flue adapter for rear outlet
installations. For top outlet installations, the blanking plate must be
removed, have the webbing fitted to its sealing face, and fitted to
the rear flue outlet. Ensure that the fold on the clamping plate is
in line with the lugs on the firebox as shown in Fig 9. Ensure that
the clamping plate does not prevent the throat plate from seating
correctly. All flue connections must be well sealed.
SOOT DOORS
It is possible to pass a 16 inch diameter sweeps brush through the
appliance but in most back outlet installations it will be necessary to
have a soot door to enable the chimney to be swept. The optional
vertical rear flue connector does allow the chimney to be swept
through the stove. Soot doors may either be in the actual brickwork
of the chimney or in the register plate. Various positions of soot
doors are shown in Figs. 5 to 8.
PRE LIGHTING CHECK
Ensure that the throat plate and upper baffle is fitted in the roof of
the appliance. For location and positioning see Fig. 2.
Check that the front fence is fitted correctly and that the door closes
properly.
COMMISSIONING
On completion of the installation allow a suitable period of time for
the fire cement and mortar to dry out before lighting the fire. Make
a layer of ash or sand on the base of the stove before lighting. Check
to ensure that smoke and fumes are taken from the appliance up
the chimney and emitted safely. Also check all joints and seals. On
completion of the installation and commissioning please leave the
operating instructions with the customer and advise them on the use
of the appliance.
Fig. 5 Vertical Register Plate With Bricked Up Fireplace
Fig. 6 Horizontal Register Plate With Rear Flue Connection
Fig. 7 Horizontal Register Plate With Top Flue Connection
Soot door inside or rear of
chimney
Register plate
Alternative soot door
positions
Register plate with soot
door
Alternative soot door
positions
Register plate with soot
door
Summary of Contents for Aire 5 low
Page 1: ... Operating Installation Instructions ...
Page 2: ......
Page 18: ......
Page 19: ......
Page 20: ...your premier dealer ...