PANACHE 8040 SERVICE / FAULT FINDING INSTRUCTIONS
Pilot Linting
Follow the guidance below removal of the burner tray.
Check the pilot aeration hole for linting, use a vacuum clearer nozzle taking care not to
damage the pilot head. Do not blow compressed into the pilot as this can lodge debris in the
pilot body.
Electrode Gap
The electrode gap should be 4mm from the tip of the thermocouple probe head to the end of
the electrode wire.