background image

PPE-5034.E

 Page 2 of 2

© 2015 Charleswater

Unit 17. Millbrook Business Park, Sybron Way • Crowborough, East Sussex TN6 3JZ United Kingdom

Phone: 00 44 (0) 1892-665313 • Internet: 

Charleswater.co.uk

Testing the Footwear Circuit

1. 

Plug one of the included test leads into the black 

banana jack labeled “E” on the Calibration Unit.  

Connect the opposite end of the test lead into the 

yellow banana jack labeled “FOOT PLATE” on the 

Combo Tester.  Toggle the switch to the “FOOT 

PLATE” position.

Specifications

Accuracy:

±5%

Dimensions:

8.1 cm x 11.2 cm x 2.3 cm

Weight:

.1 kg

Figure 3.  Verifying the calibration of the wrist strap 

circuit in the Combo Tester

Figure 4.  Connecting the test lead from banana jack “E” 

on the Calibration Unit to the FOOT PLATE banana jack 

on the Combo Tester

2. 

Connect the second test lead to the red 675K 

banana jack labeled “A” on the Calibration Unit.  

Touch the opposite end of the test lead to test plate 

on the Combo Tester and press down to activate 

the test.  Be sure not to touch the banana plug or 

test plate with your skin. 

3.  Observe the response from the Combo Tester.  The 

alarm should sound, and the LOW LED should 

illuminate red.

4. 

Repeat the procedure for test points B (825K), C 

(35M) and D (40M).  The expected test results can 

be found in the following table.

Test 

Point

Resistance 

Value

Test Output

A

675K

FAIL LOW

B

825K

PASS

C

35M

PASS

D

40M

FAIL HIGH

Figure 5.  Verifying the calibration of the footwear circuit 

in the Combo Tester

Limited Warranty, Warranty Exclusions, Limit of 

Liability and RMA Request Instructions

See Charleswater’s Warranty -

http://www.charleswater.co.uk/LimitedWarranty.aspx