Section 730-514-202
13
7.
Set switches on S8 as follows: 1, 2, 4 and –1 to IN; and 4’ and –.5 to OUT.
Note: When no equalization is required or a flat frequency response of the receive amplifier is desired, place
all switches on S8 to OUT.
Figure 9. 7305-14 And 7305-19 Option Locations
Table 4. 7305-14 And 7305-19 Option Description
Switch Designation
Switch Function
Switch Position
S1, S2
150 Ohm line impedance
600 Ohm line impedance
1200 Ohm line impedance
150
600
1200
S3, S4, S5, and S6
E & N trunk/signaling, type I/III E & M non-looped, type II E&M
looped, and 2W/4W station
See Table 3
S7
2W port build-out-network (BON):
To balance 100 to 250 feet of 26 gauge cable
To balance less than 100 feet of cable
IN
OUT
S8
Cable equalization, loaded and/or nonloaded. Provides up to 11 dB
of receive equalization (1000 to 2800 Hz) in 1dB steps using
switches 1, 2, 4, and 4’ and up to –1.5 dB of receive equalization
(1000 to 400 Hz) in –0.5 dB steps using switches –.5 and –1
See Table 5
Front Panel RCV GN
RCV path gain adjustment of up to +24 dB in 0.1 dB steps
See Table 4
Front Panel XMT GN
XMT path gain adjustment of up to +24 dB in 0.1 dB steps
See Table 4
Front Panel RCV ATN
RCV path attenuation adjustment of up to +24 dB in 0.1 dB steps
See Table 4
Front Panel XMT ATN
XMT path attenuation adjustment of up to +24 dB in 0.1 dB steps
See Table 4
Summary of Contents for 7305-14 4W-2W
Page 5: ...Section 730 514 202 5 Figure 5 Typical 4W 4W Application For 7305 14 19...
Page 6: ...Section 730 514 202 6 Figure 6 Typical 2W 4W Application For 7305 14 19...
Page 7: ...Section 730 514 202 7 Figure 7 7305 14 4W 4W 2W SF To E M Issue 2 Block Diagram...
Page 8: ...Section 730 514 202 8 Figure 8 7305 19 4W 4W 2W SF To E M W LBK Issue 2 Block Diagram...