Section 365-336-202
11
– Company name and address
– Contact name and phone number
– Inventory of equipment being shipped
– Particulars as to the nature of the failure
– Return shipping address
3.
Ship the equipment, purchase order, and above-listed information, transportation prepaid, to the ser-
vice center address shown below.
CI Service Center
503 N.E. 15th St., P.O. Box 339
Casey, IL 62420–2054
4.
Most repaired or replaced units will be returned within 30 or 45 days, depending on the product type
and availability of repair parts. Repaired units are warranted for either 90 days from the date of repair
or for the remaining unexpired portion of the original warranty, whichever is longer.
12.
SPECIFICATIONS
12.1
Agency Compliance
(a) Recognized under Underwriters Laboratories Standard 1459, Second Edition. Compliance is re-
stricted to inside plant wiring. Field repairs may void compliance.
(b) FCC P.15 Class A.
(c) Meets Canadian CSA and DOC requirements.
12.2
Electrical Specifications
12.2.1. Power
(a) POWER REQUIREMENTS: Power is supplied via the 3609–XX PSU which is part of the 360/363
Channel Bank common equipment.
12.2.2. Transmission
(b) 4W XMT INPUT TLP RANGE: +13.0 to –19.5dB.
(c) 4W RCV OUTPUT TLP RANGE: +13.0 to –19.5dB.
(d) TRANSMIT AND RECEIVE PRESCRIPTION ATTENUATION: 0.0 to 32.5dB in 0.1dB steps.
(e) LONGITUDINAL BALANCE (REFERENCED TO –16dBM TLP): 74dB minimum at 200Hz to 1KHz;
69dB minimum at 3kHz.
(f) SIGNAL TO DISTORTION RATIO: 35dB minimum at zero to –30dBm0; 29dB minimum at –40dBm0;
25dB minimum at –45dBm0.
(g) RETURN LOSS: 23dB minimum at 300Hz to 3KHz; 28dB minimum at 1kHz.
(h) TRANSMIT/RECEIVE IDLE CHANNEL NOISE: 20dBrnC0 maximum.
(i) TRANSMIT AND RECEIVE PATH FREQUENCY RESPONSE: (Referenced at 1kHz)