Section 365-001-201

9

7.9

Full Bit Encoding/Decoding (screw options XC, YC)

Screw options XC and YC condition the channel unit for either full 8-bit encoding/decoding (no signaling) or 7 5/6
bit encoding/decoding (busy condition transmitted to far end). For full 8-bit decoding, open screw YC. For 7 5/6 bit
decoding, close screw YC. The 8-bit encoding and decoding provides a better signal-to-noise ratio than the 7 5/6
bit encoding and decoding.

8.

ALIGNMENT

8.1

Transmit Alignment

The XMT attenuation push-on jumpers provide attenuation from 0 to 16.5 dB in increments of 0.1 dB to accom-
modate an input TLP range from –9.5 to +7 dBm. To adjust the transmit path to the proper operating level, the
difference between –9.5 and the transmit TLP and tip and ing must be calculated.

[XMT ATTN = TLP–(–9.5)]

For an input TLP of 7 dBm, the XMT ATTN = 7–(–9.5) = 16.5 dB. Se the sum of the push-on jumpers to 16.5 (all
to the IN position).

8.2

Receive Alignment

The RCV attenuation push-on jumpers provide attenuation from 0 to 16.5 dB in increments of 0.1 dB to accom-
modate an output TLP range from +6 to –10.5 dBm. To adjust the receive path to the proper operating level, the
difference b6 and the receive TLP at T1 and R1 must be obtained.

[RCV ATTN = +6–TLP]

For an output TLP of –12.5 dBm, the RCV ATTN=+6–(–10.5) = 16.5 dB. Set the sum of the push-on jumpers to
16.5 (all to the IN position).

9.

TESTING

After mounting, installation, optioning and alignment, use the following steps to test the unit.

Step

Action

1.

Place a call end-to-end through the facility to verify proper operation.

2.

If trouble is encountered, re-check all installer connections, options and alignment settings and verify
that the channel unit is making positive connections to the backplane connector. Then re-test.

3.

If trouble persists, replace unit with a similar unit known to be in operating order and retest the facility.
Channel unit testing for fault diagnosis or verification of circuit operation is provided in section
360–001–20X.

10.

TECHNICAL ASSISTANCE

10.1

Technical Assistance — U.S.

If technical assistance is required, contact Charles Industries’ Technical Services Center at:

847–806–8500
847–806–8556 (FAX)
800–607–8500
[email protected] (e-mail)

10.2

Technical Assistance — Canada

Canadian customers contact:

905–821–7673 (Main Office)
905–821–3280 (FAX)

Summary of Contents for 3650-01

Page 1: ...ein subject to change without notice Page 1 of 12 3650 01 03 2 Wire Equalized Transmission Only Channel Units with Lead Conditioning 2W ETO w LC CONTENTS PAGE Part 1 GENERAL 2 Part 2 INSPECTION 2 Part...

Page 2: ...brid balancing compromise network of 2 15 uF in series with 900 ohms 3650 01 or 600 ohms 3650 03 Built in jack J3 to mount an optional 3690 00 10 compromise network subassembly or an optional 3690 01...

Page 3: ...n 4 CIRCUIT DESCRIPTION Refer to the block diagram in Figure 3 while reading the following circuit description 4 1 Transmit VF Path VF signals applied to the input tip and ring leads pins 50 and 48 ar...

Page 4: ...Section 365 001 201 4 Figure 3 Block Diagram...

Page 5: ...coding close option YC 10 Coil type test point 22 Screw options AC BC and JC are used to provide sealing cur rent Close Option Open Option Function AC BC JC Supply sealing current to the loop JC AC BC...

Page 6: ...es and connector to verify proper alignment and the absence of foreign material CAUTION Use the following steps to mount the unit Step Action 1 Align the channel unit with the appropriate card guided...

Page 7: ...acing all of the jumpers in the OUT position results in 0 dB attenuation 7 5 RCV Attenuation push on jumpers Eight push on jumpers select up to 16 5 dB attenuation in 0 1 dB increments for adjusting t...

Page 8: ...ttenuation when all jumpers are in the IN position See part 7 5 A Set to the OPEN position if jack J3 is equipped or if an external PBN BOC is used Open Closed AC BC JC For external sealing current at...

Page 9: ...t TLP range from 6 to 10 5 dBm To adjust the receive path to the proper operating level the difference between 6 and the receive TLP at T1 and R1 must be obtained RCV ATTN 6 TLP For an output TLP of 1...

Page 10: ...n the out of service unit in the carton in which the replacement was shipped using the pre addressed shipping label provided Call your customer service representative at the telephone number above for...

Page 11: ...0 49 to 0 24 3400 0 to 1 2 0 to 1 2 4000 14 minimum 14 minimum 5100 32 minimum 32 minimum g Longitudinal balance 62 dB or less at 200 Hz to 1 kHz 60 dB or less at 3 kHz h Signal to distortion ratio 3...

Page 12: ...cifications are shown in Table 3 Table 3 Physical Specifications Feature U S Metric Height 4 2 inches 10 6 centimeters Width 1 35 inches 3 4 centimeters Depth 10 3 inches 26 7 centimeters Weight 16 ou...

Reviews: