High  efficiency  wide  input  voltage 

PFC programmable Charger   

90V~265VAC  input 

For  4S~24S  LiPo/LiFe  battery 

1~25Amps  1500W  max. 

                                                     

www.chargery.com

   

                                     

page

 8

   

total 

16

 

Program Setup 

1.

 

On charger idle interface, press 

knob 

button for 2 seconds enter 

into Program Setup menu.   

2.

 

LCD  displays  the  following  information  in  sequence  and  you  can 

modify its value. When you want to alter a parameter value, press 

the 

knob 

button  make  the  value  blink then  modify  the  value by 

rotate the

 

button. The new value will be confirmed and saved by 

pressing  the  button  again.  Press 

knob

  buttons  alternate  different 

items, and press 

knob 

to quit the setup menu. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: 

 

All parameters will be remembered by the C10325 till next change.

 

 
 

 

Picture 3 

Program setup

 

Setup the Temperature unit, 

 or 

℉, 

default 

.

 

Temp. Unit 
--->             

 

Setup the maximal charge current, range from 1A~25A, step 0.1A, default 
25A. It is only active for power supply.

 

Max current 
--->              60A

 

Setup  the  fan  starting  temperature,  range  from  30~50

,

  step  1

default  35

.

  The  fan  speed  will  increase  with  the  temperature  go 

Fan ON Temp. 
--->              40

 

The beeper sounds for each button press to confirm your action. These 
sounds can be ON or OFF. Default ON.

 

Buzzer 
--->             

ON

 

This menu sets the back-light time of LCD screen backlight. 
Options: 

1MIN, 5MIN, 10MIN, 20MIN and Always on, default 5MIN.

 At 

default  5min,  LCD  back-light  will  be  off  to  save  the  power,

  press 

knob

 

resume the back-light.

 

BACK-LIGHT TIME 
--->              5MIN

 

Setup  over  temperature  protection,  range  from  70~110

,

  step  1

default 110

.

 Over the temperature, the charger will power off

 

Shut Down Temp. 
--->              80

 

Summary of Contents for C10325

Page 1: ...rger High efficiency wide input voltage 90V 265VAC Input For 4S 24V LiPo LiFe battery 1 25Amps 1500W max Thanks for your purchasing the intelligent and powerful charger Read the ENTIRE instruction man...

Page 2: ...t current less interference and Conform to European Commission Regulation no 278 2009 and Energy Star Version 2 0 AC 90 265V worldwide operation need not any alternative switcher worldwide safe operat...

Page 3: ...4S 10 102 2 50 4 10 4 15 LiFe 5S 28S 10 102 5 2 00 3 65 3 75 LiTo 7S 36S 10 100 8 1 50 2 75 2 80 Pb 6S 41S 10 102 5 1 75 2 40 2 50 delta Voltage mV Min type Max NiMH NiCd Auto 10 102 100 300 1000 CC W...

Page 4: ...20 0 11 42 4 41 3 35 2 26 4 22 0 12 46 2 45 0 38 4 28 8 24 0 13 50 1 48 8 41 6 31 2 26 0 14 53 9 52 5 44 8 33 6 28 0 15 57 8 56 3 48 0 36 0 30 0 16 61 6 60 0 51 2 38 4 32 0 17 65 5 63 8 54 4 40 8 34 0...

Page 5: ...r setup NO Decrease charge current and charge Charge current is less than setup Or delta voltage is large than setup NO Stop charging automatically Initialize and work at idle mode ready to charge Pre...

Page 6: ...emperature is also displayed but C10325 is at idle mode no output to save power consumption 5 Press knob shortly can choose Battery type press again on Battery type such as LiPo can enter into LiPo ch...

Page 7: ...MH NiCd 8 At any time Press knob shortly stop charging The charger will work at idle mode to save power consumption Generally you needn t disconnect it from AC outlet because it only consume under 1W...

Page 8: ...be remembered by the C10325 till next change Picture 3 Program setup Setup the Temperature unit or default Temp Unit Setup the maximal charge current range from 1A 25A step 0 1A default 25A It is onl...

Page 9: ...tal 16 As power supply On Battery type interface choose power supply setup output voltage and maximal output current the charger will work as a programmed power supply you can set up the output voltag...

Page 10: ...100 of load PF 0 97 at 220VAC and 100 of load Output Voltage 10 102V programmed Voltage accuracy 1 Current accuracy 1 Ripple voltage 150mV Charge Current 1 25A programmed Power 1500W max Protection O...

Page 11: ...ge PFC programmable Charger 90V 265VAC input For 4S 24S LiPo LiFe battery 1 25Amps 1500W max www chargery com page 11 total 16 Packaging Information C10325 base unit 1pcs Power cable 1pcs Communicatio...

Page 12: ...se or Open relay or MOSFET NOT only cause battery voltage fluctuation at a large range shorten mechanical switch or electronic switch life but also extend charging time notably Chargery BMS and charge...

Page 13: ...off automatically and turn on manually Over Voltage Output voltage over 2V of setup for 2 seconds C10325 turn off automatically and turn on manually Over temperature The heat sink temperature over set...

Page 14: ...and maybe of interest MODEL DESCRIPTION COMMENTS BMS16T 2 16S battery management system BMS24T 2 24S battery management system S400 High efficiency wide input voltage PFC charger 6 15V 25A 400W outpu...

Page 15: ...iency wide input voltage PFC programmable Charger 90V 265VAC input For 4S 24S LiPo LiFe battery 1 25Amps 1500W max www chargery com page 15 total 16 Version history Version Output Voltage Output Curre...

Page 16: ...ects in material and workmanship This warranty is effective for 12 months from date of purchase If within the warranty period the customer is not satisfied with the products performance resulting from...

Reviews: