![Chargery BS12 V2.3 Operating Instructions Manual Download Page 3](http://html1.mh-extra.com/html/chargery/bs12-v2-3/bs12-v2-3_operating-instructions-manual_2591413003.webp)
2S-12S LiPo & LiFe battery Monitor and Saver BS12 V2.3
www.chargery.com
page 3 total 6
Operating guideline
1.
Connect the battery to BS12, keep the polarity correct. The detailed connection diagram is as the
following figure 1, figure 2 and figure 3.
2.
The Device will initialize the beeper and LED, beeper sounds once time, warning LED flash once
time.
3.
2 seconds later, the BS12 will display the cell count, total voltage on the top line, and warning
voltage, delay time, warning time on the bottom line from left to right. The middle area, each cell
voltage is displayed. When any cell voltage reaches the dynamic lowest value, it is displayed in
RED
color, the lowest voltage will be updated with the value changes.
4.
At any time, you can press SET button shortly turn off the display and press again resume. If the
back-light time is always on, it is invalid.
5.
While alarming, press SET button shortly turn off alarm at any time.
In flight, BS12 can alarm loudly and a large WARNING RED LED flash when any cell voltage under
setup value till the cell voltage over warning voltage.
If the cell voltage is still under warning voltage, the unit will beep and flash repeat for the warning
time.
The unit includes reverse polarity detection, and 2.54mm pin distance balance connector for all kinds
of battery.
Connection Diagram
1.
One 2S-6S battery can plug into the socket1 directly, 3S connections as following.
Figure 1
SET
UP/DOWN
Socket 2
cell 1
cell 2
cell 3
Socket 1
LED
BEEPER
BEEPER
6+
1-
12+
7-
BPG
+
-
+
-
+
-
-
+
jump
Socket 1
Socket 2
Cell count
Pack voltage
Cell count
Pack voltage
Socket 1
Socket 2