Chargery BM16LP Operating Instructions Download Page 4

 
 
 
 

                     

3S-16S LiPolymer battery Monitor and Saver                                    BM16LP V2.0

 

www.chargery.com

                                                                                                                           

page 4    total 5

 

Specifications: 

 

Battery range: 3S-16S LiPolymer battery pack   

 

Over discharge warning cell voltage: 

2.80~4.20V

 

step 0.05V, default 3.00V 

 

Over charge warning voltage: 

3.90

~

4.30V 

per 

cell,

 

step 0.05V, default 4.25V 

 

Delay time when start to warnning:

2S

 

 

Warning time:

20S 

per period 

 

Accurate scope of the cell voltage: 

-5mV/+5mV

 

 

Cell  voltage  display  range:0.50V~4.99V,  NO 

display when under 0.50V 

 

Temperature display range:0.0

~99.9

℃, 

 

 

Display 0.0 when under 0.0

 

 

Display 99.9 when over 100

 

 

SOC indicator:   

 

RED area @ 0~15% of SOC   

 

YELLOW area @ 16~35% of SOC 

 

GREEN area @ 36~100% of SOC 

 

Pins distance: 2.54mm   

 

Size:70*65*11 (L*W*T, mm)   

 

Weight: 30g 

 

Warning LED: 11000mCd, @ 2.0V, 20mA   

 

Warning beeper: 85dB @ 12V, 25mA 

 

Package:  transparent  heat  shrink  tube  or 

Customized AL alloy case 

 

Program setup 

Before driving your e-bike or e-scooter etc., you can set up many important parameters prevent your 

battery from over charge or discharge or over temperature. 

1.

 

Connect your battery to BM16LP 

2.

 

Press SET button for 3 seconds enter into Program Setup menu. 

3.

 

Press UP or DOWN button select the item, press SET shortly make the value flash, and press UP 

or DOWN change the value.    Press SET button shortly confirm the change. After finish all setup, 

press SET for 3 seconds quit the setup menu. 

4.

 

Over charge warning voltage range is 

3.90~4.30V per cell,

 step 0.05V, 

default 4.25V

. During 

charge, when any cell voltage over the value, the unit will alarm. 

5.

 

Over discharge warning voltage range is 

2.80~4.20V

 step 0.05V, 

default 3.00V

. During driving, 

when any cell voltage under the value, the unit will alarm. 

6.

 

Battery  temperature  range  is 

30~80

  step  1

default  50

.  During  driving,  when  battery 

temperature over the value, the unit will alarm. 

7.

 

Battery gauge (SOC) range is 

5~90%

 step 1%, 

default 30%

. During driving, when battery gauge 

under the value, the unit will alarm..   

8.

 

LCD back-light time range is 

1, 5, 10,20min and always ON,

 

default 5min

. when LCD back-light 

ON time reach setup value, it will turn off, and press any button to resume. Press SET button save 

setup and quit setup mode.   

9.

 

When quit setup mode, the device will remember all parameters till next change.   

Summary of Contents for BM16LP

Page 1: ...ontrolled high performance Battery Monitor For 3S 16S LiPoly battery pack Chargery Power Co Ltd Head Office Add Chuangye Road Nanshan Shenzhen 518054 China Zip code 518054 Tel 86 755 2643 6165 Fax 86 755 2641 2865 Email admin chargery com cn Web www chargery com ...

Page 2: ...oard Cell count battery pack voltage and battery gauge is displayed simultaneously BM16LP will record the lowest voltage of each cell during discharge after you stop driving your bike scooter etc you can press UP or DOWN button to display these voltages cell number background color is green and the lowest cell voltage displayed in RED text press the button again display real voltage Beeper sound a...

Page 3: ...m pin distance balance connector for all kinds of battery Connection Diagram There are 2 sockets connecting to battery pack socket 1 is for 3S 8S and socket 2 for 9S 16S battery 1 One 3S to 8S battery can plug into the socket 1 directly 6S connections as following Figure 1 2 For two battery packs connect them in series first and then plug battery 1 into socket 1 and battery 2 into socket 2 separat...

Page 4: ...erature 1 Connect your battery to BM16LP 2 Press SET button for 3 seconds enter into Program Setup menu 3 Press UP or DOWN button select the item press SET shortly make the value flash and press UP or DOWN change the value Press SET button shortly confirm the change After finish all setup press SET for 3 seconds quit the setup menu 4 Over charge warning voltage range is 3 90 4 30V per cell step 0 ...

Page 5: ...acturing defect the accessory will be replaced or repaired Your selling dealer is your first point of contact for warranty issues Return postage costs are the responsibility of the user in all cases Please submit copy of original receipt with the return Damage due to physical shock dropping on the floor etc inappropriate power supply unstable output voltage and insufficient power etc water moistur...