MS3450 

Stand-on Floor Scale 

USER MANUAL 

 
 

Please keep the instruction manual at hand all the time for future reference.

 

 

Summary of Contents for MS3450

Page 1: ...amended by 2007 47 EC Medical Device Directive Please see separate document showing on sticker of device for above CE marking Authorized EU Representative Manufactured by Charder Electronic Co Ltd No...

Page 2: ...C guidance and manufacturer s declaration 7 SPECIFICATIONS 12 PANEL 13 KEY FUNCTIONS 13 LCD DISPLAY SYMBOLS 14 SYMBOLS information 15 OPERATION 15 SETTING UP 20 PRINT function and data transmission 21...

Page 3: ...hing value can be read off after a stable weighing value has been obtained Before any use the scale must be checked for correct condition by the authorized person SAFETY INSTRUCTION Before putting the...

Page 4: ...m the mains power supply before cleaning 36 3 Connection failure for data transmission to PC or printer Wrong connection wires or faulty wires for transmission between the digital indicator load cells...

Page 5: ...her external objects within weighing area The weighing scale is not put in a solid firm ground area such as carpet floor or lawn 4 MAINTENANCE The scale does not require any routine maintenance Howeve...

Page 6: ...for operation 2 If the problem still persists inspect soldering of controller PCB or replace the controller PCB Overload This indicates that the scale s load sensor s have been overloaded Reduce the...

Page 7: ...pplied at the device Number as an example Please note the accompanying documents or Observe operating instructions Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C...

Page 8: ...ment RF emissions CISPR 11 Class B The MEDICAL SCALE MS3450 is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power sup...

Page 9: ...burst IEC 61000 4 4 2kV for power supply lines 1kV for input output lines 2kV for power supply lines Not applicable Mains power quality should be that of a typical commercial or hospital environment S...

Page 10: ...ironment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 KHz to 80 MHz 6 V in ISM bands between 0 15 MHz and 80 MHz 80 AM at 1 kHz 3 Vrms Portable and mobile RF communications equipment should be used...

Page 11: ...Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicte...

Page 12: ...er W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10...

Page 13: ...Capacity 300 kg x 0 1 kg Accuracy 200g Weight Unit Kg lb LCD Display 1 4 LCD digital display Dimension Platform size 310 x 310 mm Column Height 900mm Key Functions UNIT SEND ON OFF ZERO HOLD BMI TARE...

Page 14: ...area of human body For many clinical purpose BSA is the better indicator of metabolic mass than body weight because it is less affected by abnormal adipose mass BSA is commonly used in medicine parti...

Page 15: ...daptor AC adapter 1 6 User manual IN 00011 1 14 UNIT Key to switch kg or lb and to change height value under BMI mode HOLD BMI HOLD key and BMI Body Mass Index key LCD DISPLAY SYMBOLS BSA Body surface...

Page 16: ...l of battery power Stability sign Negative sign Zero indication Battery symbol 24 8 Printout Data Through USB cable connector Click OK button to complete the setting The PC will retrieve the weighing...

Page 17: ...reading can easily be read Note Determination of average value is not possible when a person moves too much HOLD function won t work if the weight is under 2 kg 1 Switch on the scale The diagnostic se...

Page 18: ...nds First display will show HOLD and lock weight then display show height value 4 Adjust height value by using and keys 5 Switch between digits by using key 6 Press to confirm height value 7 Display w...

Page 19: ...C printer com port with USB cable connector transmission For use on Windows Vista or higher please download hyper terminal software program from Charder website http www chardermedical com download dl...

Page 20: ...2 Press key and hold for 6 seconds to enable setting mode 3 LCD shows SETUP first and then A OFF appears Switch between modes and menu Reverse switch between modes and menu Confirm setting MENU AUTO O...