Parameters of RS232 interface   
Set parameters of the scale interface on the connected 
device. It is not possible to change the scale parameters.   

  Baud rate: 9600 bps   

  Parity check: None 

  Data length: 8 bits   

  Stop bit: 1 bit   

 

Handshake: RTS/CTS 

 

 

Data code: ASCII.

 

 

 

 

 

 

Summary of Contents for MS 4940

Page 1: ...0 MS 4940 Medical Scale USER MANUAL Please keep the instruction manual at hand all the time for future reference...

Page 2: ...ADAPTOR STANDARDS 14 KEY FUNCTION 14 LCD DISPLAY SYMBOLS 16 USING SCALE 17 USING HOLD FUNCTION 17 USING TARE FUNCTION 19 MS 4940 STORING AND RE CALLING PRE TARE WEIGHT 20 USING BMI FEATURE 23 MS4940...

Page 3: ...ns for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the following instructions These batteries should be kept a...

Page 4: ...ed wipes or similar when cleaning the scales Please do not use large amounts of water when cleaning the scales as this will cause damage to the scales electronics you should also refrain from using co...

Page 5: ...the fault or supply a replacement unit Replaced parts shall be the property of CHARDER Should the fault repairs or replacement delivery not be successful the statutory provisions shall be valid The pe...

Page 6: ...ld waste but should be handed in to an electrical electronic equipment recycling centre You can obtain further details from your local council your municipal waste disposal company or the firm which y...

Page 7: ...ke them to communal collection points Carefully read this operation manual before setup and commissioning even if you are already familiar with Charder scales Transport and storage temperature limit i...

Page 8: ...F emissions CISPR 11 Group 1 The MEDICAL SCALE MS4940 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby elect...

Page 9: ...applicable Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1kV line s to line s 2kV line s to earth 1kV differential mode Not applicable Mains po...

Page 10: ...940 should assure that is used in such and environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 KHz to 80 MHz 3 Vr...

Page 11: ...transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accura...

Page 12: ...frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2...

Page 13: ...ty 20 C 60 C 10 95 RH LCD Display 1 0 inch LCD display with 5 and 1 2 digits Dimension 360 W x 480 D x1100 H mm Column only 1000 mm Key Functions ON OFF PRINT BMI HOLD PRE TARE TARE CLEAR ENTER 0 9 M1...

Page 14: ...13 PANEL MS 4940...

Page 15: ...14 POWER ADAPTOR STANDARDS CAUTION The device is only compatible with restricted power adaptors in dashed block below KEY FUNCTION...

Page 16: ...result on the display determine stable weighing value To reset the display to 0 0kg display Zero the scale 2 of full capacity M1 5 To store 5 pre tare values PRE TARE Setup target weight for tare bef...

Page 17: ...ight is stable Minor weight Weight under zero Zero symbol Weight is at zero point Low battery Battery need to charge or replaced PRE TARE Indication kg BMI Indication NET WEIGHT Indication WEIGHT Indi...

Page 18: ...le stabilizes and stable sign shows on the screen Direction If a person is heavier than the scale capacity the display will show the Err prompt overload USING HOLD FUNCTION MS 4940 are provided with t...

Page 19: ...luctuating weight values and then calculates average weight and displays the result on the screen Remove the object person from the scale platform The object person s weight reading will remain on the...

Page 20: ...us giving the true weight of the product person being tested Place the object need to be tare on the tread platform Press TARE key after the weight stabilizes and stable sign displays Place the object...

Page 21: ...he display will show blinking m sign Press numeral key 1 5 to assign the position to pre tare weight For Example Press 1 to assign position 1 to preset tare weight The display will blink and make beep...

Page 22: ...link Enter PRE TARE weight using 0 9 keys For example 10kg Press ENTER key to confirm the pre tare weight the display will show the minus sign on left of the pre tare weight value Press M1 5 key the b...

Page 23: ...TARE VALUE DESCRIPTION EXAMPLE Long press PRE TARE key for 3 seconds the display will show the blinking m sign Press numeral key 1 5 to choose pre tare value Press ENTER key to confirm the pre tare w...

Page 24: ...n centimeters 1 MS 4940 Turn ON the scale using key Proceed to weigh as normal After the weight is stable and stable sign displays on the screen press key Display will change to display Key in the hei...

Page 25: ...24 Body Mass Index Categories Classification of weight for adults over 18 years on the basis of Body Mass Index according to WHO 2000 EK IV and WHO 2004 WHO World Health Organization...

Page 26: ...ll display successively AUTO OFF TIME SETUP This enables operator to select the auto turn OFF time of the device BUZZER ON OFF SETUP This enables operator to select beep sound ON OFF Auto off time 120...

Page 27: ...the results You can use external printer directly to print out the results Simply press the PRINT Button after weighing and taking BMI B Using Computer to print out the results You can use Hyper Termi...

Page 28: ...27 Step 4 Find Communications Step 5 In Communications section click on HyperTerminal Step1 5 Step 6 Name the connection and click OK Button...

Page 29: ...28 Step 7 Select COM 1 2 3 4 under Connect Using Section and press OK...

Page 30: ...bits Stop bit 1 bit Handshake RTS CTS Data code ASCII Click OK button to complete the setting Step 9 Print out the results After weighing and calculating BMI of the patient press the print button on...

Page 31: ...nterface Set parameters of the scale interface on the connected device It is not possible to change the scale parameters Baud rate 9600 bps Parity check None Data length 8 bits Stop bit 1 bit Handshak...

Page 32: ...NG 1 Assembling column with base 2 Connecting wire between column and base first 3 Tightening four screws at the bottom of base Assembling is complete NOTE The indicator here is an example Not totally...

Page 33: ...ght rod cable with scale indicator Height will be transmitted from HM200D 201D to MS4940 when MS4940 s BMI mode is activated HM201M is mechanical height rod has same assembly procedure with HM200D 201...

Page 34: ...lease disconnect the adaptor from main power supply before taking out the AC adaptor pin from indicator INSTRUCTION FOR CHARGING AND CONNECTING If prompt displays on the LCD please charge the scale wi...

Page 35: ...TION FOR REPLACING BATTERIES 1 Removing the battery cover 2 Take the battery housing out 3 Replacing new batteries 4 Batteries are well installed 5 Installing the battery housing 6 Reinstalling the ba...

Page 36: ...rom connector in the battery compartment Remove battery cover and take battery holder out of battery compartment Connect cable with connector and install rechargeable battery pack in battery compartme...

Page 37: ...36 ERROR MESSAGE...

Page 38: ...manufacturing factory under the warranty or at a certain cost for the replaced parts plus the workmanship charge if not covered under the warranty Before you contact our Authorized Dealer in your cou...

Page 39: ...l indicator load cells Wrong indicator models Wrong internal wiring or wire broken In case of the following defective mode occurs it is suggested to contact your nearest Authorized Dealer for further...

Page 40: ...cause the weigh to malfunction Software system crash Resonator faulty Load cells with faulty grinding standard Key buttons failure Front key panel damaged or disconnected 3 Buzzer malfunction Wrong we...

Page 41: ...40...

Page 42: ...ives 93 42 EEC as amended by 2007 47 EC Medical Device Directive 2014 31 EU Non automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE marking...

Reviews: