Page 10
Control Box
The Control Module has two modes of operation;
-
Count Mode:
Unit counts up from 0 e.g. 1,2,3,4,5 indefinitely, until the count is paused or the unit
switched off. If the counter reaches 999 then it will reset to 000.
-
Countdown Mode:
The desired drop count is set using the up / down arrows in increments of 5. The unit will
then count down and stop at zero. THIS IS THE RECOMMENDED MODE OF OPERATION!
The unit can be fixed to a suitable surface on the towing vehicle using screws through the fixing lugs hidden under
the two flaps on the left and right of the unit.
Specification
Supply Voltage: 12V DC nominal, 16V MAXIMUM Power
Consumption:
OFF: 0.01A
ON: 0.05A
MOTOR RUNNING: 5A *If at all possible wire direct to battery due to current draw*
Operating Temperature: -10°C to +40°C
Fuse: Thermal Reset Polyfuse (Non-serviceable)
Operating life: 100,000 cycles
Protection rating: IP67
Incorrect polarity protection: Yes, diode.
WARNING: This control box features several thermal-rest polyfuse. If this fuse is tripped through a fault
condition, the fuse will reset after approximately 10 seconds when the fuse has cooled down
sufficiently. In hot ambient conditions this can take significantly longer; likewise, in cold ambient conditions this
will take less time.