background image

MIRACLE MAX

PLUS

Summary of Contents for MIRACLE MAX PLUS

Page 1: ...MIRACLE MAX PLUS...

Page 2: ......

Page 3: ...S BASIC INFORMATION ABOUT WATER IONIZERS PRODUCT DESCRIPTION INSTALLATION PRODUCT USAGE INSTRUCTIONS MINERAL PORT USE IONIZER CARE HOW TO CHANGE THE FILTER WARNING TROUBLESHOOTING SPECIFICATIONS 4 9 1...

Page 4: ...THAN GIVING THE WATER ITS BASIC LIFE FORM THANKS TO CHARGED ELECTRONS IT IS TURNED INTO ALKALINE LIVING WATER EACH IONIZER WE OFFER CONTAINS PLATINUM COATED TITANIUM PLATES ELECTRODES WHICH FORM THE...

Page 5: ...PROCESS OF ELECTROLYSIS THE HYDROGEN BONDS BETWEEN WATER MOLECULES ARE PARTIALLY OPENED GENERATING SMALLER GROUPS OF 5 TO 6 WATER MOLECULE CLUSTERS AT THE SAME TIME UNDER THE ACTION OF ELECTRIC FIELD...

Page 6: ...AIN PIPE NEGATIVE POLE ALKALINE CREATES A GREATER NUMBER OF ELECTRONS E WHICH PENETRATE THE WATER WE DRINK WHILE ELECTRONS E PRODUCED BY POSITIVE POLE ARE DRAWN BY ITS POSITIVE CHARGE UNLIKE THE ALKAL...

Page 7: ...x POSSIBILITY OF MODULATING THE VALUES OF ORP FROM 1200 TO 920 x PARENTAL CONTROL LOCK FOR DESIRED PH LEVEL x AUTOMATIC EVALUATION OF ELECTROLYTIC VALUES ENSURING STABILITY OF SELECTED PH x AUTOMATIC...

Page 8: ...old cleaning xPlant watering xBeauty use xMoisturizing xpH neutral xMedication xSuitable for baby milk preparation xOptimal for first time drinking xSupplies minerals xImprovement of overall childern...

Page 9: ...FRONT PANEL C SIDLE FLOW CONTROL VALVE D DEVICE TOUCH CONTROL PANEL E IONIZED WATER OUTLET PRODUCT DESCRIPTION BACK VIEW F MINERAL PORT G MOUNTING HOLES HPJ 7000 FILTER PANEL A1 SILVER I POWER CORD Y...

Page 10: ...10 BOTTOM VIEW J DRAIN FLOW REGULATOR VALVE K DRAIN WATER OUTLET L SOFTWARE UPDATE CONNECTOR MSOURCE WATER INLET N FUSE O AC SOCKET J K M N O L J...

Page 11: ...S FOR FIXING OF DRAIN OUTLET F PH REAGENT DROPS KIT PH REAGENT DROPS PH TESTING BOTTLE COLOUR CHART G AC POWER CABLE HMINERAL INSERT BASKET ONE INSTALLED IN THE DEVICE I FAUCET DIVERTOR VALVE FOR QUIC...

Page 12: ...OM PRE FILTRATION C DRAIN OUTLET D IONIZED WATER OUTLET E DEVICE FRONT PANEL F PRE FILTRATTION PRE FILTRATION SYSTEM IS OPTIONAL EQUIPMENT AND IS NOT PART OF THE IONIZER PACKAGE G SOURCE WATER INLET B...

Page 13: ...T DIVERTER IT MUST GO IN AT LEAST 12MM TIGHTEN WITH HOSE CLAMP 2 MAKE SURE YOU HAVE THE FAUCET DIVERTER WITH THE RUBBER GASKET AND AERATOR EXTENSOR IF NEEDED FOR FEMALE THREADS ON FAUCET 5 USE PLIERS...

Page 14: ...K CONNECT WHICH IS PLACED AT THE BACK OF THE DEVICE MARKED AS OUT AT THE BOTTOM PUSH THE TUBE AS FAR AS YOU CAN IT SHOULD GO IN ABOUT 16MM 1 SCREW THE FLEXIBLE SPOUT INTO THE ROTATING NECK OF THE IONI...

Page 15: ...MORE INFORMATION 3 CONNECT THE 1 4 TUBE WITH THE 1 4 PRESSURE REDUCER ONLY IF NECCESSARY 1 RUN THE 1 4 TUBE THROUGH THE KITCHEN UNIT AND INSERT IT INTO WATER INLET QUICK CONNECT OF THE DEVICE WHICH I...

Page 16: ...IS A PART OF THE INSTALLATION KIT 1 SCREW THE FLEXIBLE SPOUT INTO THE ROTATING NECK OF THE IONIZER PLACED AT THE TOP OF THE DEVICE 2 TURN CLOCKWISE UNTIL O RING ON THE FLEXIBLE SPOUT IS IN DO NOT OVER...

Page 17: ...17 Your path to healthy water PRODUCT USAGE A B C D E F G H I J K L N M TOUCH PANEL DESCRIPTION...

Page 18: ...SING WITH MEDICATION AND FOR MAKING BABY FOOD G LEVEL 1 ACIDIC WATER ACIDIC 1 SUITABLE FOR COSMETIC USE FACE CLEANSING AND SKIN MOISTURISING H LEVEL 2 ACIDIC WATER ACIDIC 2 SUITABLE AS ORGANIC DETERGE...

Page 19: ...S OR UP TO 12 MONTHS DEPENDING ON THE QUALITY OF INCOMING WATER F FILTER LIFE INDICATOR G PH INDICATOR THE DISPLAYED VALUE CAN DIFFER FROM THE ACTUAL ONE DUE TO DIFFE RENCES IN QUALITY AND CONDITIONS...

Page 20: ...ACIDIC WATER IS PRODUCED C STRONG ACIDIC WATER CAN ONLY BE SELECTED WHEN THE IONIZER IS OFF DURING THE PROCESS OF PRODUCING THE STRONG ACIDIC WATER IT WILL NOT BE POSSIBLE TO CHANGE TO ANY OTHER WATE...

Page 21: ...NESIUM HIMALAYAN ROCK SALT 3 PUT THE CAP BACK ON THE BASKET PORT AND TURN CLOCKWISE TO LOCK 4 SELECT THE DESIRED WATER LEVEL AND TURN THE DEVICE ON FOR MORE INFORMATION REFER TO THE CHAPTER MINERAL PO...

Page 22: ...D YOU LL SEE THE ICON ON THE SCREEN TO UNLOCK PRESS AND HOLD THE BUTTON AGAIN FOR 3 SECONDS AND YOU LL HEAR A VOICE PROMPT INDICATING THE OPTION HAS BEEN DEACTIVATED TDS VALUE ADJUSTMENT PRESS AND HOL...

Page 23: ...HE BACK MENU SETTING PRESS ENTER UNTIL YOU SEE A LANGUAGE OPTION PRESS OR BUTTON TO CHANGE THE LANGUAGE AND PRESS BUTTON TO SAVE THE SELECTION PRESS AND HOLD THE BUTTON FOR 5 SECONDS TO EXIT SELF CLEA...

Page 24: ...G PRESS AND HOLD THE BUTTON FOR 5 SECONDS TO ACCESS THE BACK MENU SETTING PRESS UNTIL YOU SEE A CLEAN OPTION ON THE SCREEN PRESS AND HOLD AND BUTTONS AT THE SAME TIME FOR 5 SECONDS AFTER THE PROMPT PR...

Page 25: ...ON THE SIDE OF THE DEVICE OR THE BALL VALVE TO THE MINIMUM AND INSERT THE CHOSEN MINERAL IN THE MINERAL BASKET ACCORDING TO INSTRUCTIONS BELOW Your path to healthy water NOTE 1 BY USING LOW QUALITY MI...

Page 26: ...COMMENDED TO PERFORM SERVICE CLEANING EVERY 2 MONTHS TO MAINTAIN YOUR WATER IONIZER AT BEST PERFORMANCE AND TO PREVENT CALCIUM BUILTUP INSIDE ELECTROBATH PLEASE REFER TO THE INSTRUCTION ON THE CHANSON...

Page 27: ...LE TERMS REPLACE THE WHITE FILTER PAD PP CLOTH LOCATED AT THE BOTTOM OF THE C CLEAN CARTRIDGE WHEN NECESSARY THERE ARE EXTRA PADS INCLUDED IN THE C CLEAN PACKAGE NOTE IN CASE THE DEVICE IS NOT PROPERL...

Page 28: ...LOOKING AT THE IONIZER FROM THE FRONT REMOVE THE LEFT PANEL BY SLIDING IT UPWARDS REMOVE THE FILTER UNLOCK THE FILTER BY TURNING IT ANTICLOCKWISE INSERT THE NEW FILTER 1 3 2 4 HOW TO CHANGE THE FILTE...

Page 29: ...29 LOCK THE NEW FILTER BY TURNING IT ANTICLOCKWISE DO THE FILTER SERVICE RESET SEE FILTER COUNT RESET INSTRUCTIONS P 24 SLIDE THE PANEL DOWNWARDS TO ITS ORIGINAL PLACE 5 7 6 Your path to healthy water...

Page 30: ...THE POWER OUTLET WHEN CLEANING IT THIS WILL HELP PREVENT DAMAGES TO IONIZER S BODY OR ELECTRONICS DO NOT INSTALL THE IONIZER IN AREAS OF EXTREME COLD OR HEAT IF YOU NOTICE ANY LEAKS FROM THE DEVICE CL...

Page 31: ...ICAL SHOCK OR FIRE DO NOT CLEAN THE IONIZER USING WATER SPRAY IT COULD CAUSE AN ELECTRICAL SHOCK ALWAYS DISCONNECT THE IONIZER FROM THE ELECTRICITY BEFORE CLEANING DO NOT USE CABLES OR PLUGS WORN WITH...

Page 32: ...NOT BE USING IONIZER FOR A PERIOD LONGER THAN ONE DAY UNPLUG THE DEVICE FROM THE POWER OUTLET AND CLOSE THE WATER VALVE TO PREVENT LEAKAGE IF YOU ARE NOT GOING TO USE THE DEVICE FOR AN EXTENDED PERIO...

Page 33: ...the cut is straight and not at an angle and reconnect to fitting making sure it goes as far in as possible Measured values are not what they should be pH reagent drops might be expired or dysfunctiona...

Page 34: ...reduce build ups The frequency of flushes depends on the hardness of the water Restriction of water flow Check the side flow control valve water diverter valve and main shut off valve If any of these...

Page 35: ...ly closed water flow will be restricted Have the filters been changed If the filters haven t been changed the flow restric tion could be an indication of the need to replace the filters Dirt and debri...

Page 36: ...ONIZER MODEL MIRACLE MAX PLUS RATED VOLTAGE FREQUENCY AC 100 240V 50 60 HZ IONIZER DIMENSIONS 247 157 335 WIDTH X DEPTH X HEIGHT IN MM POWER 175W MAXIMUM WATER PRESSURE 8 70 PSI WATER TEMPERATURE 5 40...

Reviews:

Related manuals for MIRACLE MAX PLUS