APPLICATION
The Model VA unit cooler is a deluxe unit designed for use in
small reach-ins, back bar and under counter refrigerators, and
many other applications where a small, compact unit is
required. The thermal expansion valve mounts inside the unit.
The unit can be mounted from the ceiling or off the back wall
or end walls.
FEATURES
• Textured aluminum cabinet.
• Molded Lexan
®
fan guard.
• Improved drain pan overlaps coil surface to catch all
condensate.
• Stainless steel screws - prevent rust streaks.
• Plate-type aluminum fins with full collars on expanded
copper tubes.
• Expansion valve mounts inside cabinet.
Model VA
Reach In Unit Cooler
• Internal junction box for electrical connection.
• Pigtail leads in junction box.
• Motors are thermally protected and permanently lubricated.
• Optional corrosion-resistant coated coil available (VAK) for
optimum protection in corrosive environments.
• UL listed for the United States and Canada; UL classified to
NSF standards.
VA (K) 08 B E
Vintage
A = 115/1/60
B = 208-230/1/60
VA = Reach-In
Unit Cooler
K = Coated Coil
(Optional)
Size
NOMENCLATURE
MODEL
DIMENSIONS (INCHES)
VA
A
B
C
D
E
F
H
J
K
W
06
4
5
/
16
13
1
/
4
4
5
/
16
—
—
3
3
/
8
6
7
/
8
5
1
/
4
8
1
/
8
12
1
/
2
08
4
5
/
16
13
1
/
4
4
5
/
16
—
—
3
3
/
8
6
7
/
8
5
1
/
4
8
1
/
8
12
1
/
4
12
4
1
/
2
18
3
/
4
5
5
/
16
—
—
3
3
/
8
8
4
7
/
8
8
1
/
8
18
17
5
1
/
4
14
3
/
4
5
1
/
4
9
2
1
/
2
4
9
3
/
4
6
13
/
16
10
1
/
2
14
DIMENSIONAL DATA
MOTOR DATA
CONNECTIONS (INCHES)
APPROX.
MODEL
BTUH
115/1/60
208-230/1/60
COIL
SHIP WT.
VA
10˚F TD
CFM
QTY
TOTAL FLA TOTAL FLA
INLET
SUCTION
DRAIN
(LBS.)
06
600
135
1
0.8
0.4
1/2FN
3/8ID
1/2OD
9
08
800
130
1
0.8
0.4
1/2FN
3/8ID
1/2OD
9
12
1200
265
1
1.6
0.8
1/2FN
3/8ID
1/2OD
14
17
1700
245
2
1.0
0.5
1/2FN
1/2ID
1/2OD
11
Performance/Electrical Data