background image

8

STEP 1: Plumb the system into your water supply

INSTALLATION INSTRUCTIONS

Unpack equipment. 
Systems are sized for 1.5”, 2”, or 3” inlet / outlet. 

     
            With the bypass loop in bypass position, turn on the main water supply. Open
            a cold soft water tap nearby and let run a few minutes or until the plumbing 
            is free from foreign material (usually solder or debris from cutting the pipe) 
            that may have resulted from the installation. Once clean, close the water tap.

*

 

 

Note:   This system is for INDOOR use only. The system may be installed in  

 

 

 

any orientation as long as it is configured in the order shown above.

Hub

Summary of Contents for Drop D-CPS

Page 1: ...Chandler Systems Installation Manual Commercial Protection Valve D CPS...

Page 2: ...Be sure to check out the dropconnect com website periodically for more information about additional DROP products as they are released 833 BUY DROP 833 289 3767 dropconnect com To further help you op...

Page 3: ...ubricant Do not use pipe dope or any sealant other than Teflon tape on threaded connections Threads on the tool free connection nuts do not require any tape because they use an O ring seal Tape is onl...

Page 4: ...g current water flow peak flow today daily average of the last 90 days as well as many useful historical charts Automatically integrates with other components on your DROP System DROP is a water manag...

Page 5: ...d out of service To take your system out of service close the ball valve on the inlet side of the Motorized Valve and the ball valve on the outlet side of the Transducer Assembly Then open the ball va...

Page 6: ...on COMMERCIAL PROTECTION CONTROL VALVE FLOW METER 1 5 2 or 3 LEAK DETECTORS Contains 2 or 4 and includes batteries HUB Mounting Rack REMOTE 1 5 NPT CONNECTORS Optional MOTORIZED VALVE 1 5 2 or 3 HOW T...

Page 7: ...SE YOUR SYSTEM 1 4 2 6 Read Manual Ventilate Use Eye Protection Protect nearby materials when soldering Use only lead free solder 5 If existing plumbing is copper install grounding strap before creati...

Page 8: ...n water supply Open a cold soft water tap nearby and let run a few minutes or until the plumbing is free from foreign material usually solder or debris from cutting the pipe that may have resulted fro...

Page 9: ...areas of the facilty will expand the network This is important to consider if you have leak detectors that are located in far extremes of the building If you wish to connect your system to local WiFi...

Page 10: ...EP 6 Install 9V Battery into your Hub CPS Control Box 9 Volt Battery back up enables your valve to continue to protect your facility from leaks during a power outage To install the battery remove the...

Page 11: ...ICES HOME PROTECTION VALVE STATUS Navigation description examples can be found in the User Guide Set High and Low Temperature Notifications The DASHBOARD provides a system information overview The DEV...

Page 12: ...App that has not been seen Flashes indicate that the DROP Remote is communicating with other devices Color codes for normal operation To turn off water in your facility place your finger on the water...

Page 13: ...13 SYSTEM NOTES...

Page 14: ...e other than DROP If the unit has not always been operated within the factory recommended temperature limits and at a water pressure not exceeding 125 psi during storage use operation accident or alte...

Page 15: ...rantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment...

Page 16: ...Copyright Chandler Systems Inc DROP is a product of Chandler Systems Inc All rights reserved DROPCPS1121TV...