Chandler Limited TG MICROPHONE CASSETTE User Manual Download Page 7

7

UM TGMC-120117

Utility Cluster

Within the TG2 section, exists a cluster of utility push-button 
switches labeled as follows: 

DI, LINE, 48v, and PHASE

DI

Provision is made for accommodation of instrument level sig-

nals by means of a direct injection facility or 

DI

.

Engaging the DI facility is achieved by setting the push-button 
switch labeled 

DI

 to the inward position, this allows the Pre 

Amp/EQ section to accept instrument level signal via the ¼” 
input connector, which is located on the front panel. 

When using the DI facility, the output signal will be available 
from the Pre Amp/EQ section output XLR connector, which 
is located on the rear of the unit.

Note:

  Instrument level is not the same as line level signal.

Tip:

  Enabling the DI facility decouples the Pre Amp/EQ sec-

tion’s input XLR, therefore creating a handy mute feature. 

Line

The Pre Amp/EQ section is capable of accepting line level 
signal. 

To accommodate line level signal into the Pre Amp/EQ sec-
tion, first set the push-button switch labeled 

Line

 to the in-

ward position, then apply line level source to the 

Pre Amp/EQ

 

input XLR connector, which is located on the rear of the unit. 

Tip:

  Sending line level source into the Pre Amp/EQ section 

is a great way to further process material by adding the rich 
harmonic texture available from this historic circuit; use a pair 
of TG Microphone Cassettes on the mix bus! 

48v

Provision is made for 48 volts phantom powering of con-
denser microphones, should they require it. Phantom power 
may be enabled by setting the push-button switch labeled 

48v

 

to the inward position, use only for microphones that require 
it. 

Warning:

  Only engage or disengage phantom power while a 

microphone is connected to the Pre Amp/EQ section of the 
cassette. Disconnecting a microphone while phantom power 
is on may cause damage to equipment downstream. Never 
use phantom power with ribbon microphones. Do not en-
able phantom power when a line level device is connected at 
the 

Pre Amp/EQ

 input XLR connector.

Phase

The push-button switch labeled 

Phase

, when set to the in-

ward position, transposes the Pre Amp/EQ section input 
XLR leads, therefore reversing polarity of the incoming signal 
by 180º. This facility may be useful in multi-microphone sce-
narios, when a microphone is not ideally placed, a cable is 
wired incorrectly, or source material is out of phase.

48v

DI

LINE

PHASE

COARSE GAIN

FINE GAIN

RUMBLE FILTER

-8

-6

-4

-2

0

+2

+4

-10

+6

+8

+10

OUT

33

41

47

65

82

110

®

+30

+35

+40

+45

+50

+25

+56

+20

+60

Summary of Contents for TG MICROPHONE CASSETTE

Page 1: ...BASS EQ IN OUTPUT 5 6 4 3 2 1 0 7 8 9 10 IN 8 6 4 2 0 2 4 10 6 8 10 8 6 4 2 0 2 4 10 6 8 10 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 10 9 8 7 6 5 4 3 2 1 0 COARSE GAIN F...

Page 2: ...5 Audio Input Output Connections 5 Link 5 TG2 6 Coarse Gain 6 Fine Gain 6 Rumble Filter 6 Utility Cluster 7 CURVE BENDER 8 Treble 8 Bass 8 Presence 8 EQ In 8 Output 8 TG1 OPTO 9 Important Notes on Us...

Page 3: ...s Central Research Laboratories teams the EMI TG12345 Mark I desk ushered in a sea of change in sound and flexibility at Abbey Road Studios Installed in Abbey Road s Studio Two in November 1968 and m...

Page 4: ...vide protection for shipment and storage Please retain the container and associated materials for future use Note PSU rigid foam surrounds and sheets are not included for equipment shipped without a p...

Page 5: ...Microphone Cassette exists two sets of male and female XLR connectors one pair for the Pre Amp EQ section and the other for independent ac cess of the Compressor All audio XLR connectors are wired pi...

Page 6: ...e on historic REDD 51 valve consoles and activated via a plug in jumper The Rumble Filter was fixed at 30 Hz and was unique in its circuit design TG2 The TG2 section of the TG Microphone Cassette is a...

Page 7: ...the rear of the unit Tip Sending line level source into the Pre Amp EQ section is a great way to further process material by adding the rich harmonic texture available from this historic circuit use...

Page 8: ...was a rotary switch EQ In The toggle switch labeled EQ IN when positioned downward inserts the Curve Bender into the audio path conversely in the upward position the equalizer section is bypassed Outp...

Page 9: ...1 Opto compressor is understanding the Gain Reduction meter and Hold control without signal present The meter scale range begins below 0 and extends to 20 at the end of the red region The degree of co...

Page 10: ...regardless of where the meter needle is placed the hotter the input signal into the TG1 Opto is the greater the rate of compression be Tip To cope with inconsistent peak level programme set the Hold...

Page 11: ...ypes Sharp and Rounded Sharp knee Sharp is equivalent to limit mode on the TG1 and Zener Lim iters and is considered hard When the Knee switch is set to Sharp compression will be full ratio Tip Sharp...

Page 12: ...products purchased outside of the United States is provided by local or regional authorized Chandler Limited distributors To obtain service or repairs please contact your local dealer or regional dis...

Page 13: ...States If you live in the United States and your product was purchased through a U S Dealer please contact your dealer OR call 319 885 4200 or e mail support chandlerlimited com WhatYou Must Do for Wa...

Page 14: ...STATE STATUTE LIMITATION OF LIABILITY THE LIABILITY OF CHANDLER LIMITED IF ANY AND PURCHASER S SOLE AND EXCLUSIVE REMEDY FOR DAM AGES FOR ANY CLAIM OF ANY KIND WHATSOEVER REGARDLESS OF THE LEGAL THEO...

Reviews: