106
Timer Board Diagnostic Testing
Press and release the scrub/Ext Wash switch if equipped
If the green indicator light for the scrub switch flashes, the
scrub/ext wash switch works
START
SCRUB
POWER
PR
4
before testing, turn the power switch OFF and allow the machine to complete the
drain cycle.
check incoming voltages
1
Open the door
If the green cycle indicator light blinks, the dOOr sWItch and cyclE lIght work
Note: this function times out after 10 seconds
close the door
2
indicator light
POWER
SC
PRIME
START
Press and release the start sWItch
If the green cycle indicator light flashes the start switch works
3
indicator light
If one or more components do not run, see below
POWER
SC
PRIME
START
PrEss start
3 tImEs
5
fill valve
•
detergent pump
•
rinse-aid pump
•
drain valve opens
•
drain valve closes
•
wash pump
•
drain pump or sanitizer pump (if applicable)
•
to test the timer board and the following components, press
and release the start switch 3 times with the door closed
If the components listed below are operating properly, they
should run consecutively for a few seconds each
cONdItION
POssIblE causE/sOlutION
One of the components in step 5 does not run
check the component that did not run
the wash pump is the only component that runs
check the 4 amp fuse on the timer board
the wash pump is the only component that will
not run and the 4 amp fuse is good
check pump motor/see troubleshooting guide
None of the components run in step 5
check neutral wire/see troubleshooting guide
diagnostic testing for p/n 0712105 solid state timer board
- effective serial # W081217467 and up
0512979
Summary of Contents for UH130
Page 10: ...vi Blank Page This Page Intentionally Left Blank ...
Page 54: ...44 Wash Pump Motor Assembly All Models 1 2 6 3 4 5 7 9 8 10 11 12 13 ...
Page 59: ...49 Blank Page This Page Intentionally Left Blank ...
Page 68: ...58 Upper Final Rinse Piping UH230 UH230B 10 13 8 7 6 3 2 1 1 4 5 2 2 12 14 15 1 15 9 11 ...
Page 74: ...64 Fill Solenoid Valve UH130 UH130B UL130 1 2 3 4 9 5 6 7 8 ...
Page 84: ...74 Rinse Aid Pump Assembly UH130 UH130B UL130 1 4 6 6 8 9 To Fill Chute 10 2 3 5 7 7 ...
Page 86: ...76 Sanitizer Pump Assembly UL130 To Injection Point 11 10 ...
Page 88: ...78 Control Panel UH230 UH230B 1 2 3 3 2 6 5 7 5 10 8 8 9 9 11 12 12 10 4 ...
Page 90: ...80 Control Panel UH130 UH130B 1 2 3 6 7 10 8 8 9 9 11 12 12 10 4 5 5 ...
Page 92: ...82 Control Panel UL130 7 9 8 3 6 1 2 4 7 5 5 ...
Page 96: ...86 Door Assembly All Models 1 3 4 5 6 7 8 2 2 ...
Page 98: ...88 Dish Racks Line Strainer PRV 1 2 3 4 ...
Page 100: ...90 This Page Intentionally Left Blank Blank Page ...
Page 102: ...92 UL130 Low Temperature Undercounter Electrical Schematic UL130 ...
Page 104: ...94 Timing Chart for UH230 UH230B Timing Chart for UH130 UH130B UL130 Timing Charts ...