12-1/4"
12-1/16"
18-1/4"
15-1/8"
57-3/4"
25-15/16"
18-3/4"
60-5/16"
33"
2
4
1-15/16"
38-1/16"
18-13/16"
A
3
5-3/4"
7.5HP
B
D
C
F
E
2HP
G
16-5/16"
20-7/8"
36-7/8"
32-3/8"
20-9/16"
10"
3
19-1/8"
11-3/16"
2HP
11"
6-1/4"
1HP
4
2
1HP Recirculating Pump
Top View
24"
FLOORLINE
8"
1
48"
16"
24"
FLOORLINE
8"
1
48"
16"
9"
8"
4"
7.5 Hp - 30" Pulper
Waste Handling System
P7-30 PULPER
Utilities
1
Electrical
See Chart.
2
Optional Recirculation Pump
3
Drain
1-1/2" NPT.
4
Cold Water
1/2" NPT cold water connection.
Warning:
Plumbing and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary and
safety codes and the National Electrical Codes.
Note:
Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied
(by others) in common water supply line at
service connection.
P7-30 with Optional Recirculating Pump
Mounted on Rear of Water Extractor
Front View
Side View
Remote Mounted
Control Cabinet
Front View
Top View
Item Qty. Description
A
1
Slurry Chamber 30" dia.
B
1
Motor – Main Drive 7.5 Hp
C
1
Water Extractor Drive Motor 2 Hp
D
1
Water Extractor
E
1
Discharge Chute
F
1
Scrapping Tray
G
1
Start/Stop Station