Volume crated: 

122 cu. ft./3.5 cu. m.

Shipping weight crated: 

750 lbs./340 kg.

Dimensions shown in inches and [millimeters]

Warning: 

Plumbing and electrical connections should be made by

qualified personnel who will observe all the applicable plumbing,
sanitary, safety codes and the National Electrical Code.

Note: 

Water Hammer Arrestor (meeting ASSE-1010 standard or

equivalent) to be supplied 
(by others) in common water supply line at service connection.

Venting Notes: 

Fabricated duct size: 

3-7/8" x 15-7/8" (Outside dimensions) 

Machine only

Minimum

Maximum

Supply Ckt.

Overcurrent

Elec.

Rated

Conductor

Protective

Specs.

Amps

Ampacity

Device

220/60/3

47

60

60

380/50/3

47

60

60

MACHINE CONNECTION

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115  USA • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com

Utilities

1

Electrical

A

Machine connection 

B

Booster connection 

2

Hot Water

3/4" [19] NPT 140°F/60°C min. hot water connection.
(40°F/22°C rise booster) 
3/4" [19] NPT 110°F/49°C min. hot water connection.
(70°F/39°C rise booster)
Flow pressure 20-22 psi.

3

Drain 

1-1/2" NPT machine connection. Maximum flow 15 gpm.

4

Vents

A

Load end: 200 CFM @ 1/4" [6] S.P.

B

Unload end: 400 CFM @ 1/4" [6] S.P. 
(With blower-dryer increase room ventilation by 600 CFM.)

44" [1118] Single Tank 
High-Temperature
Rack Conveyor Dishwashing Machine

MODEL I 44

SPECIFICATIONS

Capacity

Racks per hr.

208

Wash tank 

US Gal. 

21

Liter 79

Conveyor speed (ft/min.)

5.8

Motor Horsepower

Drive

1/6

Wash

2

Water Consumption

Per hr. (max. use)

US Gal.  124

Liters 469

Per rack

US Gal.  .60

Liters 2

Heating

Tank Heat, electric (kW)

15

Electric booster (built-in)

(Available 40°F rise only)

15

Electric booster (optional)

(kW supplied for 70°F rise)

24

Venting

Load end (minimum CFM)

200

Unload end (minimum CFM)

400

Standard 20" [508] x 20" [508] 
rack complement

Peg

2

Flat

1

70°F/39°C Rise – 24kW

Electric built-in booster (booster only) 

Minimum

Maximum

Supply Ckt.

Overcurrent

Elec.

Rated

Conductor

Protective

Specs.

Amps

Ampacity

Device

220/60/3

105

115

115

380/50/3

105

115

115

BOOSTER CONNECTION

40°F/22°C Rise – 15kW

Electric built-in booster (booster only)

Minimum

Maximum

Supply Ckt.

Overcurrent

Elec.

Rated

Conductor

Protective

Specs.

Amps

Ampacity

Device

220/60/3

83

110

110

280/50/3

83

110

110

Summary of Contents for Model I 44

Page 1: ...veyor drive system Shown with Vent Cowl and Damper Option Champion Industries Inc P O Box 4149 Winston Salem NC 27115 USA Tel 800 532 8591 Fax 336 661 1979 www championindustries com STANDARD FEATURES One piece cast stainless steel upper lower spray arm assemblies Standard vertical opening 20 3 4 527 Wide 26 660 leakproof doors internally fitted Front enclosure panels Stainless steel heavy gauge c...

Page 2: ...able spray arm assembly for ease of cleaning Stainless steel pump housing and impeller Larger tanks hold more water for better washing results INTEGRATED BOOSTER HEATER As well as the E Series performs we created a way to make it perform even better The electric booster heater is an exceptional value engineered within the E Series footprint to offer a variety of advantages over other booster desig...

Page 3: ...ed Table Construction 6 152 Nom Wall CONTROL CABINET 22 559 2 1 2 64 2 3 8 60 3 5 8 98 30 5 8 779 2 51 2 51 20 1 8 511 25 635 30 5 8 778 33 838 OPENING INS TRACK 1B 6 7 1 2 2 1 4 57 1 3 4 44 1 1 2 38 Can be up to 10 254 5 8 16 21 533 102 152 102 8 203 8 203 26 660 Due to an ongoing value analysis program at Champion specifications contained in this catalog are subject to change without notice Cham...

Page 4: ...e up to 10 254 5 8 16 21 533 6 152 Nom Wall CONTROL CABINET 22 559 2 1 2 64 2 3 8 60 3 5 8 98 30 5 8 779 2 51 20 1 8 511 25 635 30 5 8 778 33 838 OPENING INS TRACK 25 635 28 1 2 724 36 914 14 1 2 368 6 152 8 203 12 1 2 318 16 406 2 51 9 1 4 235 14 1 2 368 10 254 2 51 Due to an ongoing value analysis program at Champion specifications contained in this catalog are subject to change without notice C...

Page 5: ...22 C rise booster 3 4 19 NPT 110 F 49 C min hot water connection 70 F 39 C rise booster Flow pressure 20 22 psi 3 Drain 1 1 2 NPT machine connection Maximum flow 15 gpm 4 Vents A Load end 200 CFM 1 4 6 S P B Unload end 400 CFM 1 4 6 S P With blower dryer increase room ventilation by 600 CFM 44 1118 Single Tank High Temperature Rack Conveyor Dishwashing Machine MODEL I 44 SPECIFICATIONS Capacity Ra...

Page 6: ...er conveyor table mobile or stationary Table limit switch unmounted recommended on all rack conveyor installations Vent cowl stainless steel with 7 stack and locking damper Vent fan control Due to an ongoing value analysis program at Champion specifications contained in this catalog are subject to change without notice Champion Industries Inc P O Box 4149 Winston Salem NC 27115 USA 800 532 8591 Fa...