background image

64” Two Tank with Heavy Duty 36” Prewash  

Rack Conveyor  

Dishwashing Machine

Model 100 HdPW 

M

ODE

100 

HDPW 

RAC

CON

v

EYOR

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 

2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

Model MRC 90

90° Motorized  

Rack Curve

(Must be ordered with  

Roller Conveyor Table)

Cantilever 
Sideloader

 

(No hood)

Model MRC 180

180° Motorized  

Rack Curve

(Must be ordered with Roller 

Conveyor Table)

Model RCT 64 

or RCT 84

Roller  

Conveyor Table

OPTIONS & ACCESSORIES

Tank heat: choice of steam coil, steam injector,  

hot water coil
Blower-dryer with 60” hood, table, legs and  

cradle assembly

Booster Heaters – stainless steel  

  (completely interplumbed, controls are interwired)

  Steam: 40°F - 70°F rise
  Electric: 15 kW (40°F rise only)  

  (built-in 3 phase only)
  Electric: 24 kW (70°F max. rise) (3 phase only)
Cantilever sideloader (with or without hood) for  

90° load operation
Extended pawl bar (extended drive unit) for use with 

load tabling
90° Motorized rack curve (unload)
180° Motorized rack curve (unload)
Racks: peg or flat racks (specify type)
Roller conveyor table (mobile or stationary)
Steam pressure regulating valve (unmounted)
Table limit switch, unmounted (recommended on 

all rack conveyor installations)
Vent cowl, stainless steel with 7” stack and  

locking damper
Extended Vent hood, stainless steel with 7” stack 

and locking damper
Water pressure regulating valve (unmounted) 

(standard with booster)
Vent fan control
Water hammer kit
Drain temp kit
Vertical clearance through machine: 24”  

(instead of standard 20”) for large ware

Summary of Contents for Model 100 HDPW

Page 1: ...dard Features ENERGY STAR Qualified Dual pawl cradle drive system One piece cast stainless steel upper lower spray arm assemblies for ease of cleaning Internal removable scrap baskets with two piece scrap screens Standard vertical opening accommodates 18 x 26 sheet pans Wide 26 leakproof doors internally fitted for ease of cleaning Anti jam conveyor drive system Energy Sentinel Idle pump shut off ...

Page 2: ...Easily removable spray arm assembly for ease of cleaning Stainless steel pump housing and impeller Larger tanks hold more water for better washing results INTEGRATED BOOSTER HEATER As well as the E Series performs we created a way to make it perform even better The electric booster heater may be optional but it is an exceptional value engineered within the E Series footprint to offer a variety of ...

Page 3: ...ter coil Blower dryer with 60 hood table legs and cradle assembly Booster Heaters stainless steel completely interplumbed controls are interwired Steam 40 F 70 F rise Electric 15 kW 40 F rise only built in 3 phase only Electric 24 kW 70 F max rise 3 phase only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motoriz...

Page 4: ...ght 58 1 2 Machine Height 26 Door 26 Door 8 8 64 36 8 1 2 3 5 13 7 1 2 7 1 2 100 116 RINSE WASH 2HP 1 6 HP 2HP 1HP 5 Cowl Cowl BSTR 1B 6 1A 2 4A 4B 6B 5 16 70 1 2 12 1 2 14 1 2 8 10 13 17 30 7 1 2 25 17 2 Front View Without Booster Front View With Booster end View Suggested Table Construction Plan View 2 1 4 1 3 4 1 1 2 Can be up to 10 for Extended Vent Cowls 5 8 21 8 26 Door PRE WASH 2 1A 6A 6B 3...

Page 5: ...eight 58 1 2 Machine Height 26 Door 26 Door 8 8 64 36 8 1 2 3 5 13 7 1 2 7 1 2 100 116 RINSE WASH 2HP 1 6 HP 2HP 1HP 5 Cowl Cowl BSTR 1B 6 1A 2 4A 4B 6B 5 16 70 1 2 12 1 2 14 1 2 8 10 13 17 30 7 1 2 25 17 2 Front View With Booster Front View Without Booster end View Suggested Table Construction Plan View 2 1 4 1 3 4 1 1 2 Can be up to 10 for Extended Vent Cowls 5 8 21 8 26 Door PRE WASH 2 1A 6A 6B...

Page 6: ... supplied for 70 F rise 24 Steam booster lbs hr required for 40 F rise 120 Steam booster lbs hr required for 70 F rise 205 Venting Load end minimum CFM 200 Unload end minimum CFM 400 Standard 20 x 20 rack complement Peg 2 Flat 1 Venting Notes Fabricated duct size 3 7 8 x 15 7 8 Outside dimensions Plumbing Notes Because of the variation in house supplied steam and water pressures steam and water pr...