GENERAL
Accessories
•
17RS - 17" rack stand (raises working height and adds rack storage)
•
17T - 17" cabinet (raises working height and adds storage)
•
CST - Combination sink/table (scraping and sorting station)
•
101285 - Dish Rack (Peg Rack)
•
101273 - Silverware Rack (Flat Bottom Rack)
Electrical Power Requirements
Booster
Machine
Power Requirement
Model
Voltage
Rise
Full Load Amp
(125% Service Factor)
I-UH
115/50/1
N/A
7
15
(without booster)
I-UH
208/50/1
40
31
39
I-UH
240/50/1
40
34
43
I-UH
208/50/1
70
42
53
I-UH
240/50/1
70
48
60
NOTE:
208-230V/50Hz/1PH electrical supply service must be a 2-wire plus ground for connection
as shown.
—2-Wire Plus Ground Diagram
208-230V
GND
L2
L1
3