Table Of Contents

Safety Instructions ......................................................................... 1
Operation ........................................................................................ 1
Installation Instructions .................................................................. 2
Maintenance Section .................................................................... 2-3
Electrical Wiring Diagrams .............................................................. 3
Troubleshooting .............................................................................. 4

Warranty ......................................................................................... 4
General Specifications

 (Especificaciones Generales) .....................

5

Motor Specifications 

(Especificaciones Del Motor) .......................

5

Parts List - Blower Section 

 (Lista De Piezas) ............................

6-7

Parts List - Wet Section 

(Lista De Piezas) ..................................

8-9

Spanish

 (Instrucciones en Español) ...........................................

9-12

Read And Save These Instructions

Safety Rules

1. Read instructions carefully.
2. Disconnect all electrical service that will be used for the unit before

you begin the installation.

3. Electrical hook up should be done by a qualified electrician, so that

all electrical wiring will conform to your local standards.

4. For a maximum safety precaution, make sure cooler cabinet is

properly grounded to a suitable ground connection.

5. Cooler must be connected to proper line current, voltage and cycle,

as stamped on cooler motor and pump motor specification plate.

Operation

To eliminate delivery of hot air when starting cooler, Start the pump
without the blower for the first few minutes, then turn on the blower
motor.

These coolers may be used without water for ventilation purposes.
When outside air is cool (for example, at night) or when humidity is
high the water pump can be turned off.

6. This unit must be installed at a height of 10 feet or greater from the

floor.

7. Always 

Disconnect Power 

before performing any maintenance.

Summary of Contents for FAD242 Series

Page 1: ...ve These Instructions Safety Rules 1 Read instructions carefully 2 Disconnect all electrical service that will be used for the unit before you begin the installation 3 Electrical hook up should be don...

Page 2: ...he water supply line to any soft water applications Install float valve and fill pan Refer to Fig 3 Remove items 1 2 3 and 4 Insert float body 5 through hole in back post panel as shown Install washer...

Page 3: ...eaning pumps Cleaning the pumps is necessary once a year at start up For your safety discon nect from power source and unplug pump Remove the pump from the mount bracket Remove the base of the pump Fi...

Page 4: ...te air delivery with cooler running Motor cycles on and off Musty or unpleasant odor Noisy Inadequate cooling Excessive humidity in building Limited Warranty This warranty is extended to the original...

Page 5: ...0318 110227 4L580 FAD248B212 110483 2 1 208 230 5 8 110318 110227 4L580 FAD248B232 110464 1 2 3 208 230 5 8 110318 110227 4L580 FAD248B234 110464 1 2 3 460 5 8 110318 110227 4L580 NOTE All motors are...

Page 6: ...6 110497 Replacement Parts Drawing Dibujo De Piezas De Repuesto FAD242B FAD248B 1 2 3R 3L 4 17 18 19 20 20 19 18 19 18 5 6 7R 7L 8R 8L 9 10 11 12 13 13 15 14 16 23 21 24 25 26 27 28 22...

Page 7: ...l Frente 318117 024 318117 030 18 Connect Bracket Abrazadera Del Conectar 214120 001 214120 001 19 Lift Bracket Soporte De Levantamiento 212101 001 212101 001 20 Inspection Panel Panel De Inspecci n 2...

Page 8: ...8 110497 Replacement Parts Drawing Dibujo De Piezas De Repuesto FAD242W8 FAD248W8 15 20 3 7 8 11 9 10 13R 14R 17 19 6 5 18 2 16 12 21 4 1...

Page 9: ...Water Reservoir Bandeja Acumuladora De Agua 281036 281036 9 Perforated Panel Parrilla Perforada 218121 004 218121 005 10 Evaporative Media Medio Evaporativo 110115 110116 11 Media Shield Pantalla Pro...

Page 10: ...er acceso al cableado fig 1 Conecte el cableado en la caja al suministro el ctrico seg n las diagramas el ctricas ADVERTENCIA Compruebe que la caja del enfriador tenga la debida conexi n a tierra para...

Page 11: ...Negro Rojo Verde Verde Caja De Empalme Recept culo GFCI Caja Del Enfriador Desconector Requerido Situado Dentro De La Vista Del Enfriador 240V 60 Hz Trif sico O 460V Tierra 120V 60Hz 1 Fase Circuito...

Page 12: ...e Aver as No arranca o no sale aire Sale poco aire cuando la unidad est funcionando Motor se apaga y se enciende Enfriamiento inadecuado Hace Ruido Demasiada humedad en la casa Olor a encerrado olor d...

Reviews: