background image

Volume crated:  

130 cu. ft.

Shipping weight crated:  

865 lbs.

Dimensions shown in inches

Warning: 

Plumbing and electrical connections 

should be made by qualified personnel who will 

observe all the applicable plumbing, sanitary, 

safety codes and the National Electrical Code.

Note: 

Water Hammer Arrestor (meeting ASSE-

1010 standard or equivalent) to be supplied (by 

others) in common water supply line at service 

connection.

Plumbing Notes:

 Because of the variation 

in house-supplied steam and water pressures, 

steam and water pressure regulating valves 

(PRVs) may be needed. (Water PRV is standard on 

machines with booster.) The  

PRVs can either be purchased from  

Champion or obtained locally.

Venting Notes: 

Fabricated duct size:  

3-7/8” x 15-7/8” (Outside dimensions) 

 Machine only

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1 

162 

200 

200

  240/60/1  

142 

175 

175

  208/60/3  

90 

110 

110

  240/60/3  

80 

100 

100

  480/60/3  

40 

50 

50

  575/60/3  

31 

40 

40

TABle A - MACHINe CoNNeCTIoN

 Machine and steam built-in booster

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/1 

32 

40 

40

  240/60/1  

29 

40 

40 

  208/60/3  

15 

20 

20

  240/60/3  

14 

20 

20

  480/60/3  

15 

15

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com

utilities

 

1

  Electrical

A

  Machine connection (see Table A) 

B

  Booster connection (see Table B)

 

2

  Hot Water

3/4” NPT 180°F/82°C min. hot water 

connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 

connection. (40°F/22°C rise booster) 
3/4” NPT 120°F/49°C min. hot water 

connection. (60°F/34°C rise booster)
3/4” NPT 110°F/49°C min. hot water 

connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.

 

3

  Drain 

1-1/2” NPT machine connection.  

Maximum flow 15 gpm.

 

4

  Steam 

A

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSI. (Steam coil)

B

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSI.  

  (Steam injector)

 

5

  Condensate 

(no back pressure)

1/2” NPT machine return to boiler

  6

  Vents

A

  Load end: 200 CFM @ 1/4” S.P.

B

  Unload end: 400 CFM @ 1/4” S.P.  

  (With blower-dryer increase room    

ventilation by 600 CFM.)

64” Two Tank

High-Temperature

Rack Conveyor Dishwashing Machine

Model 64

SPeCIFICATIoNS

Capacity 

Racks per hr. (NSF rated) 

277

Wash tank (US gal.) 

21

Conveyor speed (ft/min.) 

7.7

Motor Horsepower 

Drive  

1/6

Wash 2

Rinse 2

Water Consumption

US Gal. per hr. (max. use) 

124

US Gal. per rack 

.45

Heating

Tank Heat, electric (kW) 

25

Tank heat, steam  

(lbs/hr. required at  

15 PSI flow pressure) 

75

Electric booster (built-in) 

(kw supplied for 40°F rise) 

15

Electric booster (built-in) 

(kW supplied for 70°F rise) 

24

Steam booster (lbs./hr.  

required for 40°F rise) 

120

Steam booster (lbs./hr.  

required for 70°F rise) 

205

Venting

Load end (minimum CFM) 

200

Unload end (minimum CFM) 

400

Standard 20” x 20”  

rack complement

Peg   

2

Flat   

1

TABle B - BooSTeR CoNNeCTIoN

 40°F/22°C Rise – 15kW 

  Electric built-in booster (booster only)

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/3  

42 

50 

50

  240/60/3 

36 

45 

45

  480/60/3  

18 

25 

25

  575/60/3  

15 

20 

20

 70°F/39°C Rise – 24kW 

  Electric built-in booster (booster only)

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

  208/60/3  

67 

80 

80

  240/60/3 

58 

70 

70

  480/60/3  

29 

35 

35

  575/60/3  

24 

30 

30

Summary of Contents for 64

Page 1: ...800 532 8591 Fax 336 661 1979 www championindustries com Standard Features ENERGY STAR Qualified One piece cast stainless steel upper lower spray arm assemblies for ease of cleaning Internal removable scrap basket and two piece scrap screen Standard vertical opening accommodates 18 x 26 sheet pans Wide 26 leakproof doors internally fitted for ease of cleaning Anti jam conveyor drive system Energy ...

Page 2: ... efficient washing Easily removable spray arm assembly for ease of cleaning Stainless steel pump housing and impeller Larger tanks hold more water for better washing results INTEGRATED BOOSTER HEATER As well as the E Series performs we created a way to make it perform even better The electric booster heater may be optional but it is an exceptional value engineered within the E Series footprint to ...

Page 3: ...oad Racks peg or flat racks specify type Roller conveyor table mobile or stationary Steam pressure regulating valve unmounted Table limit switch unmounted recommended on all rack conveyor installations Vent cowl stainless steel with 7 stack and locking damper Water pressure regulating valve unmounted standard with booster Vent fan control Due to an ongoing value analysis program at Champion specif...

Page 4: ...ration 2 1A 6A 6B 3 5 4B 1B 4A 4 4 12 Plumbing Clearance 8 8 80 64 26 Door 26 Door RINSE BSTR 8 1 2 5 34 Load Height 89 Door Removal 58 1 2 Machine Height 82 Door Open Height 20 3 4 Clear 3 7 5 7 1 2 13 WASH 2HP 1 6 HP 2HP Cowl 6 7 1 2 8 18 10 6 6A 3 2 5 6B 1A 2 2 2 3 8 30 5 8 20 1 8 2 1 2 14 1 2 56 1 2 12 1 2 43 1 4 17 13 30 2 3 5 8 30 5 8 33 4B 4A 25 16 Front View Without Booster Front View With...

Page 5: ...ration BSTR 6A 3 5 6B 1A 2 2 4B 4A Front View Without Booster Front View With Booster End View Suggested Table Construction Plan View 2 1A 6A 6B 3 5 4B 4A 4 4 7 12 Plumbing Clearance 8 8 80 64 26 Door 26 Door RINSE 8 1 2 5 34 Load Height 89 Door Removal 58 1 2 Machine Height 82 Door Open Height 20 3 4 Clear 3 5 7 1 2 13 WASH 2HP 1 6 HP 2HP Cowl Cowl 2 1A 6A 6B 3 5 4B 4A 4 4 12 Plumbing Clearance 8...

Page 6: ...onnection Machine without booster 3 4 NPT 140 F 60 C min hot water connection 40 F 22 C rise booster 3 4 NPT 120 F 49 C min hot water connection 60 F 34 C rise booster 3 4 NPT 110 F 49 C min hot water connection 70 F 39 C rise booster Flow pressure 20 22 psi 3 Drain 1 1 2 NPT machine connection Maximum flow 15 gpm 4 Steam A 3 4 NPT machine connection Flow pressure 15 30 psi Steam coil B 3 4 NPT ma...