100806 - 7500W ELEcTRic START GENERATOR
OPERATiON
21
Manual Start
1. Push the ignition switch to the “ON” position.
2. Move the choke to the “CHOKE” position.
3. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
4. Do not over-choke. As soon as engine starts, move the choke
to the “RUN” position over a 2-5 second duration.
NOTicE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
battery
NOTicE
The supplied 12V battery does re-charge while the engine
is running and the battery switch is turned ON, but it is also
recommended that the battery be fully charged at least once
per month or maintained with a trickle charger or battery
maintainer (not included).
connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC
single phase, 60 Hz electrical loads.
–
DO NOT connect 3-phase loads to the generator.
–
DO NOT overload the generator.
–
Use only a high quality, insulated, compatible (3-wire or
4-wire) grounded cord set rated equal to or greater (volts and
amps) than the receptacle plugging into.