Champion Power Equipment 71307 Owner'S Manual And Operating Instructions Download Page 16

Operation 

12 

 

Rev 71307-20100513 E

 

Stopping the Engine 

1.

 

Turn off and unplug all electrical loads. 
Never start or stop the generator with 

electrical devices plugged in or turned 

on. 

2.

 

Let the generator run at no-load for 

several minutes to stabilize internal 
temperatures of the engine and 

generator. 

3.

 

Turn the fuel valve to the “Off” position. 

4.

 

Close the OPD valve on the LPG 

cylinder. 

Do Not Overload Generator

 

Capacity

 

Follow these simple steps to calculate the 

running and starting watts necessary for 
your purposes.  

1.

 

Select the electrical devices you plan on 

running at the same time. 

2.

 

Total the running watts of these items. 

This is the amount of power you need to 

keep your items running. 

3.

 

Identify the highest starting wattage of 

all devices identified in step 1. Add this 
number to the number calculated in step 

2. Surge wattage is the extra burst of 

power needed to start some electric 
driven equipment. Following the steps 

listed under “Power Management” will 

guarantee that only one device will be 
starting at a time. 

Power Management 

Use the following formula to convert voltage 
and amperage to watts: 

 

Volts x Amps = Watts 

 

To prolong the life of your generator and 
attached devices, follow these steps to add 

electrical load: 

1.

 

Start the generator with no electrical 
load attached. 

2.

 

Allow the engine to run for several 

minutes to stabilize. 

3.

 

Plug in and turn on the first item. It is 

best to attach the item with the largest 
load first. 

4.

 

Allow the engine to stabilize. 

5.

 

Plug in and turn on the next item. 

6.

 

Allow the engine to stabilize. 

7.

 

Repeat steps 5-6 for each additional 

item. 

  NOTE 

Never exceed the generator capacity when 
adding loads.  
 

Summary of Contents for 71307

Page 1: ...om 10006 Santa Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 5000 Peak Watts 4600 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in t...

Page 2: ......

Page 3: ...agement 12 Wattage Reference Chart 13 Maintenance 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenanc...

Page 4: ......

Page 5: ...ment Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please v...

Page 6: ...mminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or seri...

Page 7: ...ating parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produc...

Page 8: ...towards the engine faster than you can let go Unintentional startup can result in entanglement traumatic amputation or laceration Broken bones fractures bruises or sprains could result When starting...

Page 9: ...fuel to the engine 2 Choke Lever Used to start the engine 3 Air Cleaner Protects the engine by filtering dust and debris from the intake air 4 Recoil Starter Used to start the engine 5 Gas Hose and Re...

Page 10: ...to reset circuit breaker 6 120 240 V 30 A Twist Lock Protected by a 20 A flip to reset circuit breaker on each 120 Volt leg of the receptacle This receptacle powers 240 Volt AC single phase loads req...

Page 11: ...it Axle 1 piece 10 Solid Wheel 2 pieces Support Leg 1 piece Vibration Mounts 2 pieces Bolt Kit Wheel Retaining Pins 2 pieces Flat Washers 2 pieces Cap Screws and Nuts 6 sets Oil Funnel 1 piece Spark P...

Page 12: ...to install the wheels not included 12 mm wrench Socket wrench with a 12 mm socket Pliers 1 Before adding oil to the engine tip the generator slowly so that the engine side is up 2 Slide the axle throu...

Page 13: ...l Damage to the generator as a result of failure to follow these instructions will void your warranty 1 Place the generator on a flat level surface 2 Remove oil fill cap dipstick to add oil 3 Add 1 16...

Page 14: ...ep the cylinder in a vertical position with the valve on top and installed at ground level on a flat surface Cylinders must not be installed near any heat source and should not be exposed to sun rain...

Page 15: ...They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power Supply UPS device Most UPS devices come with a rechargeable battery between the...

Page 16: ...ing wattage of all devices identified in step 1 Add this number to the number calculated in step 2 Surge wattage is the extra burst of power needed to start some electric driven equipment Following th...

Page 17: ...000 Water Heater 4000 Security System 180 AM FM Radio 300 Garage Door Opener 1 2 HP 500 600 Battery Charger 12V DC 110 Heating Cooling Air Conditioner 12000 BTU 1700 2500 Fan 300 600 Furnace Fan 1 3 H...

Page 18: ...e oil fill cap dipstick 6 Dispose of used oil at an approved waste management facility Spark Plugs 1 Remove the spark plug cable from the spark plug 2 Use the spark plug tool that shipped with your ge...

Page 19: ...adverse conditions Contact our help line at 1 877 338 0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours or daily...

Page 20: ...uctions in the Maintenance section 3 Change the oil 4 Remove the spark plug and pour about ounce of oil into the cylinder Crank the engine slowly to distribute the oil and lubricate the cylinder 5 Rea...

Page 21: ...cm Length 28 3 inches 72 cm Fuel Use only an approved LPG cylinder equipped with an OPD valve Flow rate 2 0 kg hr Outlet pressure 2 8 kpa 0 5 kpa Oil Oil capacity is 1 16 qt 1 1 L Spark Plugs Your ge...

Page 22: ...Specifications 18 Rev 71307 20100513 E Parts Diagram...

Page 23: ...over 1 23 GB16674 M5 16 Flange Bolt M5 16 6 24 ST02FD 02100010 Terminal 1 25 ST05FD 1152030 CPE AVR 1 26 ST05FD 1152035 Brush assembly 1 27 ST05FD 1152002 End cover 1 28 ST05FD 1152004 4 Flange bolt M...

Page 24: ...ner seal 1 77 GB6177 M5 Nut M5 8 78 ST188FD 1090003 Separator 1 79 ST188FD 1090004 Element 1 80 ST188FD 1090200 G Air cleaner cover comp 1 81 GB93 6 Spring washer 6 4 82 GB97 1 5 Washer 5 6 83 GB848 8...

Page 25: ...50002 C7 Battery black wire 1 115 ST05FD 03011112 Jacket 3 116 GB62 M6 Nut M6 2 117 ST05FD 03021111 Battery setting plate 1 118 FM12180 Battery12V18AH 1 119 ST05FD 03021104 Bolt M6 2 120 ST05FD 030211...

Page 26: ...Specifications 22 Rev 71307 20100513 E Wiring Diagram...

Page 27: ...pply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cabl...

Page 28: ...t apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected...

Page 29: ...o you including diagnosis parts and labor MANUFACTURER S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If duri...

Page 30: ...is scheduled only for regular inspection as specified in the Owners Manual shall be warranted for the ECS Warranty Period A statement in such written instructions to the effect of repair or replace a...

Page 31: ...Fittings Clamps Pressure Relief Valves Control Valves Control Solenoids Electronic Controls Vacuum Control Diaphragms Control Cables Control Linkages Purge Valves Carburetor Purge Port Connector TO OB...

Reviews: