background image

201066 - 6500W OPEN FRAME INvERTER

SPECIFICATIONS

31

SPECIFICATIONS

Generator Specifications

Generator Model

 ...........................................

 201066

Start Type

 ...................................................

Manual

Watts (Starting/Running)

 ..............................

 6500/5250

AC Volts

 .....................................................

120/240

AC Amps @ 120V (Running)

 ...................................

43.8

AC Amps @ 120/240V (Running)

 ..............................

21.9

Volts DC

 ..........................................................

12

DC Amps

 ............................................................

8

Frequency 

 .....................................................

60 Hz

Phase

 .........................................................

Single

Grounding Type

 ..........................

Neutral Bonded to Frame

Weight

 ...........................................

123.2 lb. (55.9 kg)

Length

 ............................................

26.6 in. (67.5 cm)

Width 

 ............................................

25.5 in. (64.8 cm)

Height

 ............................................

24.6 in. (62.5 cm)

Engine Specifications

Model

 .........................................................

R300P

Displacement

 ................................................

301 cc

Type

 ...................................................

4-Stroke OHV

Spark Plug

OEM Type

 .....................................................

F6RTC

Replacement Type

 ...........................

BPR6ES or equivalent

Gap

 ..................................

0.028-0.031 in. (0.7-0.8 mm)

Valve

Intake Clearance

 .................

0.002-0.006 in. (0.05-0.15 mm)

Exhaust Clearance

 ...............

0.002-0.006 in. (0.05-0.15 mm)

 

NOTICE

A technical bulletin regarding valve adjustment procedures is 
available at www.championpowerequipment.com.

Oil Specifications

DO NOT OVERFILL.

Type

 ............................................

*See following chart

Capacity

 ......................................

37.2 fl. oz. (1100 ml)

-20

0

20

40

60

Ambient temperature

Recommended Engine Oil Type

80

100

120

-28.9

°F
°C

-17.8

-6.7

4.4

15.6

26.7

37.8

48.9

10W-30

5W-30 Full Synthetic

10W-40

5W-30

 

NOTICE

Temperature will affect engine oil and engine performance. 
Change the type of engine oil used based on temperature 
shown in the 

“Recommended Engine Oil Type”

 table.

Fuel Specifications

Use unleaded gasoline with a minimum octane rating of 87 and 
an ethanol content of 10% or less by volume. DO NOT USE E15 or 
E85. DO NOT OVERFILL.

Gasoline Capacity

 ..................................

4.3 gal. (16.4 L)

Temperature Specifications

Starting Temperature Range (°F/°C)

 ...........

5 to 104/-15 to 40

 

NOTICE

An important message about temperature:

 Your product 

is designed and rated for continuous operation at ambient 
temperatures up to 104°F (40°C). When needed, it may be 
operated at temperatures ranging from 5°F (-15°C) to 122°F 
(50°C) for short periods of time. If exposed to temperatures 
outside this range during storage, it should be brought back 
within this range before operation. In any event, the product 
must always be operated outdoors, in a well-ventilated area 
and away from doors, windows and vents.

Summary of Contents for 201066

Page 1: ...ons and illustrations in this manual are as accurate as known at the time of publication but are subject to change without notice This product meets the requirements of the PGMA Portable Generator Man...

Page 2: ...all carbon monoxide risks you ll be better prepared to protect your family from this colorless oderless threat CARBON MONOXIDE SAFETY THE BIG PICTURE KNOW THE SYMPTOMS Headache Nausea Shortness of br...

Page 3: ...o Economy Mode 24 12V DC Regulated Automotive Style Outlet 24 Parallel Operation 25 Stopping the Engine 25 Moving the Generator 25 Operation at High Altitude 26 Maintenance 26 Cleaning the Generator 2...

Page 4: ...fort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this doc...

Page 5: ...g parts can entangle hands feet hair clothing and or accessories Traumatic amputation or severe laceration can result Keep hands and feet away from rotating parts Tie up long hair and remove jewelry D...

Page 6: ...nce is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and turned on CAUTION Exceeding the generator s running capacity can damage the g...

Page 7: ...into the generator at the gas station Always use an approved container to transfer the fuel to the generator DO NOT overfill the gasoline tank Always keep gasoline away from sparks open flames pilot...

Page 8: ...eado o d bil Aller l air frais et obtenir de l aide m dicale si malade tourdi ou faible ACTION LABEL ETIQUETA DE ACCI N TIQUETTE D ACTION Colors APN 3429 L SF Rev A Size 225 x 85 mm Artwork Notes 2mm...

Page 9: ...fore operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Improper connections to a building can allow current to backfeed into utility...

Page 10: ...ge of available power from generator being used RV Ready Receptacle Choke Pull choke knob to CHOKE position Run Push choke knob to RUN position Locking Receptacle SYMBOL MEANING 12V Direct Current Cir...

Page 11: ...dy them and learn their meaning Proper interpretation of these symbols will allow you to more safely operate the product Starting the Engine DANGER Move generator outside and far away from windows doo...

Page 12: ...ngine by filtering dust and debris from the intake air 4 Recoil Starter Used to manually start the engine 5 Never Flat Wheels 8 in 20 3 cm 6 Control Panel See Control Panel section 7 Quick Drain Tube...

Page 13: ...ntrol 8 Circuit Breakers Push Reset Protects the generator against electrical overloads RECEPTACLES A t 120V AC 30A RV NEMA TT 30R May be used to supply electrical power for operation of 120 Volt AC 3...

Page 14: ...ion Example 6 hours Total Run Time Total run time of the generator since first operation Example 16 hours Power Meter Power Output percentage Example 100 Output Intelligauge with Power Meter and CO Sh...

Page 15: ...cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radi...

Page 16: ...ty 1 BEFORE filling the engine with oil or gasoline tip the generator onto its recoil end Tip onto the flattened cardboard box the generator came in or other protective surface so as to not scratch th...

Page 17: ...If running generator in extreme temperatures refer to the Recommended Engine Oil Type chart 20 0 20 40 60 Ambient temperature Recommended Engine Oil Type 80 100 120 28 9 F C 17 8 6 7 4 4 15 6 26 7 37...

Page 18: ...lean fresh regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10 or less by volume y b c DO NOT mix oil with gasoline 1 Remove the gasoline cap 2 Slowly add gasolin...

Page 19: ...your Specifications section for specified type of grounding OPERATION CO Shield Carbon Monoxide CO Detection and Auto shutoff System CO Shield technology monitors the accumulation of carbon monoxide...

Page 20: ...after it was manually shut off This does not occur if generator shut off from a high CO event If CO Shield system experiences a fault and no longer provides protection the generator is shutoff automat...

Page 21: ...erly cool before transport or for storage purposes Failure to follow proper safety precautions may result in personal injury damage to the generator and void the manufacturer s warranty WARNING During...

Page 22: ...hree attempts Too much choke leads to spark plug fouling and engine flooding This will cause the engine not to start NOTICE For gasoline starting in cold ambient temperature 59 F 15 C Keep the choke i...

Page 23: ...entify the highest starting wattage of all devices identified in step 1 Add this number to the number calculated in step 2 Starting wattage is the surge of power needed to start some electric driven e...

Page 24: ...times of reduced electrical output Eco Mode allows the engine speed to idle during periods of non use The engine speed returns to normal when an electrical load is connected When the economy switch is...

Page 25: ...s plugged in or turned on 2 Let the generator run at no load for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the fuel valve to the OFF position 4 Press the en...

Page 26: ...tion at lower elevations the originally supplied standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fue...

Page 27: ...DO NOT screw in the dipstick while checking Cleaning and Adjusting the Spark Plug 1 Remove the spark plug cable from the spark plug 2 Use a spark plug socket tool not included or a 13 16 in 21 mm sock...

Page 28: ...e Governor WARNING Tampering with the factory set governor will void your warranty The air fuel mixture is not adjustable Tampering with the governor can damage your generator and your electrical devi...

Page 29: ...l and appropriate hose if necessary under the carburetor drain bolt to avoid spillage 5d When gasoline stops flowing from the carburetor replace and tighten the carburetor drain bolt and be sure to pr...

Page 30: ...g stored follow the below steps when removing from storage 1 Be sure the engine switch is in the OFF position 2 Add gasoline to the generator according to Add Fuel 3 Turn the fuel valve to the ON posi...

Page 31: ...20 40 60 Ambient temperature Recommended Engine Oil Type 80 100 120 28 9 F C 17 8 6 7 4 4 15 6 26 7 37 8 48 9 10W 30 5W 30 Full Synthetic 10W 40 5W 30 NOTICE Temperature will affect engine oil and eng...

Page 32: ...when CO Shield shutoffs occur due to accumulating carbon monoxide CO and if the red LED light blinks on the panel Move generator to an open outdoor area Point exhaust away from people and buildings Mo...

Page 33: ...ipped when CO Shield shutoffs occur due to system fault and if the yellow LED light blinks on the panel Start by confirming yellow LED light blinks when if generator shuts off If CO Shield continues t...

Page 34: ...n wrong position Move choke until it stops under RUN position or push in completely Repeated circuit breaker tripping Overload Review load and adjust See Connecting Electrical Loads Faulty power cords...

Page 35: ...or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other Exclusi...

Page 36: ...condition exits CPE will repair your small off road engine SORE and equipment at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE This Emissions Control System is w...

Page 37: ...shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replace...

Page 38: ...Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other p...

Reviews: