Winter Shut Down

Drain water. 

 Always drain all of the water out of the cooler and

water supply line when not in use for prolonged periods, and par-
ticularly at the end of the season.  Keep the water line disconnected
from both the unit and water supply so that it does not freeze.

Cover unit. 

 To protect the life of the finish, a cover for the unit is

suggested in extended periods of non use.

Cover grill.

  To help keep out cold air you can use the optional

plastic grill cover.  This cover may be purchased from your local
distributor.  To install the cover, line up the grill cover with the grill
so that the tabs on the cover will slide over the center section of the
grill.  Slide the grill cover onto the grill.  The tabs will snap into
place.  To remove, just pull the grill cover straight forward away
from the grill.

Unplug unit from power supply during extended periods of
non-use.

By following the operating, installation, and maintenance suggestions
as outlined, you can get many years of efficient and satisfactory
service from your cooler.  In the event additional information is desired,
your dealer will be more than glad to assist you in every possible
way.

Vertical Duct Conversion

This window unit can be reconfigured to a vertical tunnel configura-
tion for installation into smaller width openings.  Follow the
subsequent steps if this is desired.

1. Remove the 9 screws

from the sides and bot-
tom of the tunnel.

2. Remove the top 4

middle screws of the
top pan while holding
the tunnel in place (Fig
10).  Be careful not to
drop the tunnel or
damage to the electric
cords could occur.  You
may need to loosen
other screws in the top
pan to make it easier to remove the tunnel.

3. Rotate the tunnel 90 degrees counter-clockwise (Fig 11).  Be

careful as you rotate the tunnel that you don’t damage or discon-

Fig. 11

Fig. 12

Line up to the two

middle holes

nect the cords which are still con-
nected to the controls and the
front panel.

4. Insert the flange of the tunnel

between the front panel and the
top pan.  Line up the two larger
holes in the tunnel with the cen-
ter two holes of the top pan.  (Fig
12).

5. Using the screws taken from the

top pan, secure the tunnel to the
unit.  Do not tighten the screws,
leave them loose until the
rest of the tunnel has been
secured.

6. Line up the three holes at

the bottom of the tunnel
with the holes in the front
panel.  Using the screws
taken from the bottom of
the tunnel previously, se-
cure the tunnel to the front
panel.

7. Make sure all the screws

removed from the top pan
are in place and tighten all
screws.

8. Remove the three screws (2 in

model (R)WC35) from each side
of the front panel as shown in fig-

ure 13.  

CAUTION

: Make

sure that you do not remove the
bottom most screw.  It holds the
blower housing in place.

9. In the installation kit there are two

strips of metal that will cover the
gap in the front panel.  Line up the
holes in the metal strips to the
holes in the front panel and secure
them with the screws previously removed in step 8.  (See Fig.
13)  Install the metal strips so that there is no gap between the
top pan and the metal strip.  If there is a gap, turn the metal strip
around.

NOTE:  When mounting a cooler with this type of vertical
tunnel configuration, the unit should be supported by a flat
support or stand.  The installation method mentioned in the
owner’s manual using chains and legs should not be used.  The
filler panels in the installation kit may be used to seal off the
window above the cooler duct.

Fig. 10

Remove top
screws last. Do
Not Drop Tunnel

Wiring Diagrams

Hi
Low
Gnd
Com.

Black
Red
Green
White

Plug

Switch

Blower Motor

Pump

Motor

Manual Control

Hi
Low
Gnd
Com.

Black
Red
Green
White

Ground
Wire

Blower Motor

Pump

Motor

LockPlate

w/ Grommet

Remote Control

Control

Ground

Screw

Fig. 13

Do Not Remove
Bottom Screw

Metal
Strip

Summary of Contents for RWC35

Page 1: ...e cooler continually brings in fresh air while exhausting old air You are completely replacing the air every 2 to 4 minutes by opening windows or doors or a combination of both The air is always fresh...

Page 2: ...ff Pressing it again while in the off state will return the fan and pump to their previous operating settings When first plugging in the cooler or after power has been interrupted pressing the On Off...

Page 3: ...to retain water Overflow pipe may be removed to drain pan when necessary A garden hose may be screwed on the drain nipple to drain water away from your unit Maintenance WARNING Before doing any maint...

Page 4: ...ge or discon Fig 11 Fig 12 Line up to the two middle holes nect the cords which are still con nected to the controls and the front panel 4 Insert the flange of the tunnel between the front panel and t...

Page 5: ...chaser only Problem Possible Cause Remedy Failure to start or no air delivery Inadequate air delivery with cooler running Inadequate cooling 1 No electrical power to unit Fuse blown Circuit breaker tr...

Page 6: ...s Especificaciones Generales Model No Modelo Weight lbs Peso libras Cabinet Dimensions in Dimensiones De La Caja pulgadas Window Opening Req d in Abertura Requerida pulgadas Dry Seco Operating Lleno H...

Page 7: ...Flow Assembly Montaje De Desag e 3OA 1 3OA 1 3OA 1 36 House Leg Collar Collar De La Pata 3HL 1 3HL 1 3HL 1 37 House Leg Pata 310811 310811 310811 38 Retainers Window Panels Guarda De Retenci n Para Lo...

Page 8: ...a Las Unidades De ControlADistancia Estas unidades pueden ser controladas con los tres botones en la rejilla por delante del enfriador o con el mando a distancia El Bot n PUMP Al presionar este bot n...

Page 9: ...as NOTA Si instale la unidad sin el uso del equipo de instala ci n omite las direcciones siguientes y las de la figura 3 Quite los tornillos de la esquina de la bandeja A fig 2 Coloque la m nsula en l...

Page 10: ...rejilla Para ayudar a guardar el aire fr o de entrar en la casa usted puede utilizar la cubierta pl stica opcional Se puede comprar la cubierta de su distribuidor local Al instalar la cubierta alinee...

Page 11: ...l conducto a la unidad No apriete los tornillos D jenlos flojos hasta que el resto del conducto se ha asegurado Fig 10 Quite Los Tornillos Superiores Al ltima Vez No Deja Caer El Conducto 6 Alinee los...

Page 12: ...ctivado Cable el ctrico da ado 2 Correa muy floja o apretada 3 Motor recalentado Correa muy apretada Cojinetes de la rueda est n secos 4 Motor parado 1 Insuficiente abertura para que salga el aire 2 P...

Reviews: