100415 - 3550W WIRELESS REMOTE START GENERATOR
OPERATION
18
7. Test start and stop features.
NOTICE
Only two remote controls can be synced with one generator
at a time.
NOTICE
Changing a remote control battery may not require the user
to reset the remote control.
Starting the Engine
1. Make certain the generator is on a flat, level surface.
2. Turn the gasoline fuel valve to the “ON” position.
Wireless Remote Start
Wireless remote starting is only possible within 80 feet of the
generator.
DO NOT attempt to adjust the choke. The remote system will
automatically close and open the choke.
1. Push the battery switch to the “ON” position.
2. Push the ignition switch to the “ON” position.
3. Press and release the “START” button on the remote
control. DO NOT hold the button down, only press the
button once. The engine will attempt to start six times.
Electric Start
DO NOT attempt to adjust the choke. The remote system will
automatically close and open the choke.
1. Push the battery switch to the “ON” position.
2. Push the ignition switch to the “ON” position.
3. Press and hold the ignition switch to the “START” position.
Release as the engine begins to start. If the engine fails
to start within five seconds, release the switch and wait
at least ten seconds before attempting to start the engine
again.
CAUTION
If the ignition switch is held down in the “START” position
longer than 5 seconds it could damage the starter.
Manual Start
1. Disconnect all electrical loads from the generator. Never
start or stop the generator manually with electrical devices
plugged in or turned on.
2. Move the choke to the “CHOKE” position.
3. For restarting a warm engine, move the choke to 75% of
the “CHOKE” position.
4. Push the ignition switch to the “ON” position.
5. Pull the starter cord slowly until resistance is felt and then
pull rapidly
6. Do not over-choke. As soon as engine starts, move the
choke to the “RUN” position over a 2-5 second duration.
NOTICE
Keep choke in “CHOKE” position for only 1 pull of the recoil
starter. After first pull, move choke to the “RUN” position for
up to the next 3 pulls of the recoil starter. Too much choke
leads to spark plug fouling/engine flooding due to the lack of
incoming air. This will cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient
> 30°C (86°F):
Keep the choke in 75% of the “CHOKE”
position for only 1 pull of the recoil starter. After first pull,
move choke to the “RUN” position for up to 3 more pulls
of the recoil starter. Too much choke leads to spark plug
fouling/engine flooding due to the lack of incoming air. This
will cause the engine not to start.
NOTICE
For gas starting in cold ambient <15°C (59°F):
the choke
must be in 100% of the “CHOKE” position for recoil start
procedures. Do not over-choke. As soon as engine starts,
gradually move the choke lever to the “RUN” position over a
2-5 second duration.
NOTICE
For Wireless and Electric Start only:
A safety feature
is provided which delays the electrical power availability
during starting mode. The delay lasts for approximately 15
seconds. The delay is provided to prevent damage to the
generator if electrical loads are inadvertently turned on
during engine startup.