Chamberlain Whisper Drive Security+ HD600 Owner'S Manual Download Page 32

32

CARE OF YOUR OPENER

LIMIT AND FORCE ADJUSTMENTS:

Weather conditions may
cause some minor changes
in door operation requiring
some re-adjustments,
particularly during the first
year of operation.

Pages 27 and 28 refer to the
limit and force adjustments.
Only a screwdriver is
required. Follow the
instructions carefully.

Repeat the safety reverse test (Adjustment
Step 3, page 29) after any adjustment of limits or
force.

FORCE CONTROLS

1

3

9

7

5

1

3

9

7

5

LIMIT CONTROLS

KG

KG

THE REMOTE CONTROL BATTERY

The lithium battery should produce power for up to 
5 years.

To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.

WARNING

CAUTION

WARNING

WARNING

MAINTENANCE SCHEDULE

Once a Month

• Manually operate door. If it is unbalanced or

binding, call a trained door systems technician.

• Check to be sure door opens & closes fully. Adjust

limits and/or force if necessary. (See pages 27
and 28)

• Repeat the safety reverse test. Make any

necessary adjustments. (See Adjustment Step 3)

Once a Year

• Oil door rollers, bearings and hinges. The opener

does not require additional lubrication. Do not
grease the door tracks.

To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• Do NOT recharge, disassemble, heat above 100°C 

(212°F) or incinerate.

WARNING

CAUTION

WARNING

WARNING

To replace battery, use the visor 
clip or screwdriver blade to pry 
open the case as shown. Insert 
battery positive side up (+). 

Dispose of old battery properly. 

Replace the battery with only 
3

V

2032 coin cell batteries.

Battery 
positive 
side up (+)

NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or
modifications of this receiver and/or transmitter are prohibited, except for changing the
code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.

Summary of Contents for Whisper Drive Security+ HD600

Page 1: ...s Manual Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless The Protector System is connected...

Page 2: ...1 Assemble the rail and install the trolley 8 Fasten the rail to the motor unit and Install the idler pulley 9 Install the belt and attach the belt cap retainer 10 Set the tension 11 Installation 11 2...

Page 3: ...arage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift the door...

Page 4: ...port bracket and additional fastening hardware may be required Installation Step 10 Depending upon garage construction extension brackets or wood blocks may be needed to install sensors Installation S...

Page 5: ...nsor Access Door FINISHED CEILING Support bracket fastening hardware is required See page 16 Safety Reversing Sensor Header Wall Gap between floor and bottom of door must not exceed 1 4 6 mm Wall moun...

Page 6: ...Sensor Bracket 2 Motor Unit with 2 Light Lenses U Bracket Trolley Remote Light Control Rail Center Back Sections Rail Front header Section Idler Pulley 2 Conductor Bell Wire White White Red Your gara...

Page 7: ...30 Drywall Anchors 2 Clevis Pin 5 16 x1 1 Rope Lock Washer 5 16 7 Lag Screw 5 16 9x1 5 8 2 Hex Bolt 5 16 18x7 8 4 Clevis Pin 5 16 x1 1 4 1 Lag Screw 5 16 18x1 7 8 2 Screw 6ABx1 1 4 2 Screw 6 32x1 2 Cl...

Page 8: ...posite edge about 4 3 4 12 cm from the far end 1 Remove the straight door arm and hanging bracket packaged inside the front rail and set aside for Installation Step 5 and 12 NOTE To prevent INJURY whi...

Page 9: ...he window Keep the ribbed side toward the rail and allow it to hang until Assembly Step 5 Remove the tape from the idler pulley The inside center should be pre greased If dry regrease to ensure proper...

Page 10: ...he trolley threaded shaft is facing the rail Connect the trolley threaded shaft with the master link as illustrated Push pins of master link bar through holes in end of belt and trolley threaded shaft...

Page 11: ...in SEVERE INJURY or DEATH 3 All repairs to cables spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener 4 Disable all locks and remove all ro...

Page 12: ...f the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation To prevent possible SERIOUS INJUR...

Page 13: ...nting toward the ceiling Mark the vertical set of bracket holes Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided Lag Screw 5 16 9x1 5 8 HARDWAR...

Page 14: ...If the door spring is in the way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header brack...

Page 15: ...or setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place...

Page 16: ...th the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to opener at...

Page 17: ...ontrol by color white wire to WHT and white red wire to the RED Figure 3 2 Remove cover by gently prying at slot in top of the cover with a small flat head screwdriver Fasten with 6ABx1 1 4 self tappi...

Page 18: ...nutes when power is connected Then the lights will turn OFF Reverse the procedure to close the lens Use A19 standard neck garage door opener bulbs for replacement NOTE Use only standard light bulbs Th...

Page 19: ...he black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the...

Page 20: ...ove the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of...

Page 21: ...ging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket against th...

Page 22: ...ed alignment is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust sensor until it receives the sende...

Page 23: ...ollows depending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the doo...

Page 24: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Page 25: ...are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that l...

Page 26: ...5 16 18 Lock Washers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully clos...

Page 27: ...d in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close compl...

Page 28: ...ke small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close t...

Page 29: ...un the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the...

Page 30: ...wer is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door With a Motion Detecting Door Control this feature may be turned off as follows...

Page 31: ...nd the Keyless Entry Accessories To activate press and hold the Lock button for 2 seconds The push bar light will flash as long as the Lock feature is on To turn off press and hold the Lock button aga...

Page 32: ...Repeat the safety reverse test Make any necessary adjustments See Adjustment Step 3 Once a Year Oil door rollers bearings and hinges The opener does not require additional lubrication Do not grease th...

Page 33: ...after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment S...

Page 34: ...touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with j...

Page 35: ...actory to operate with your hand held remote control The door will open and close when you press the large push button Below are instructions for programming your opener to operate with additional Sec...

Page 36: ...e when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service people with a temporary 4 digi...

Page 37: ...remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell wire white and white red 7 41A5047 1...

Page 38: ...t socket 7 108D79 Lens 8 30B532 Capacitor 1 2 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w screws 11 41A4842 Universal replacement motor bracket assembly Complete with Motor worm bracket...

Page 39: ...ring the garage Sensor can be easily deactivated when desired 3 Button Mini Remote Control with SECURITY With key ring and fastening strip 956D 940D 10 Foot 3 m Rail Extension To allow a 10 foot 3 m d...

Page 40: ...ler for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and retur...

Reviews: