Step 2 Setting Output Relay Mode
The TriCode

TM

receiver is factory set for momentary

relay output “MNT”.

(a) Momentary mode: The output relay will be on for
.5 seconds before turning off.

(b)  Constant pressure mode: Output relay is
continuously on while receiving matching/valid ID
code from transmitter.  The output relay will turn off
immediately once receiver does not receive a
matching/valid ID code from the transmitter (Refer to
figure 3).

NOTE:  If constant pressure mode is desired, open
front cover and move mode jumper from “MNT” to
“CST” (Refer to figure 2).

FRONT VIEW

FIGURE 3

OUTPUT RELAYS & CONFIGURATION SWITCH SETTINGS

Step 3 Setting the Configuration Switch
The TriCode

TM

receiver is factory set for Linear/Delta-

3

TM

.  

Locate the configuration switch and set it to the desired
RF mode of operation (Refer to figures 2 and 3).  Modes
are as follows:

Linear/Delta-3

TM

works with all “Linear/Delta-3

TM

transmitters transmitted at 310 MHz using 8-bits ID
system.

Multi

TM

works with all “Multi-Code

TM

” transmitters

transmitted at 300 MHz using 10-bits ID system.

Stanley

TM

works with all “Stanley

TM

radio” transmitters

transmitted at 310 MHz using 10-bits ID system..