Step 2 Setting Output Relay Mode
The TriCode
TM
receiver is factory set for momentary
relay output “MNT”.
(a) Momentary mode: The output relay will be on for
.5 seconds before turning off.
(b) Constant pressure mode: Output relay is
continuously on while receiving matching/valid ID
code from transmitter. The output relay will turn off
immediately once receiver does not receive a
matching/valid ID code from the transmitter (Refer to
figure 3).
NOTE: If constant pressure mode is desired, open
front cover and move mode jumper from “MNT” to
“CST” (Refer to figure 2).
FRONT VIEW
FIGURE 3
OUTPUT RELAYS & CONFIGURATION SWITCH SETTINGS
Step 3 Setting the Configuration Switch
The TriCode
TM
receiver is factory set for Linear/Delta-
3
TM
.
Locate the configuration switch and set it to the desired
RF mode of operation (Refer to figures 2 and 3). Modes
are as follows:
Linear/Delta-3
TM
: works with all “Linear/Delta-3
TM
”
transmitters transmitted at 310 MHz using 8-bits ID
system.
Multi
TM
: works with all “Multi-Code
TM
” transmitters
transmitted at 300 MHz using 10-bits ID system.
Stanley
TM
: works with all “Stanley
TM
radio” transmitters
transmitted at 310 MHz using 10-bits ID system..