![Chamberlain MyQ Connectivity SectionalLift CS65MYQ Installation And Operating Instructions Manual Download Page 22](http://html.mh-extra.com/html/chamberlain/myq-connectivity-sectionallift-cs65myq/myq-connectivity-sectionallift-cs65myq_installation-and-operating-instructions-manual_2587346022.webp)
21
Input Voltage..............................220-240 Vac, 50 - 60 Hz.
Max. Pull Force .........................600 N.
Power ........................................150 Watt.
Normal Torque...........................5 Nm.
Max door weight.........................90 kg.
Max lift under spring tension .....20 kg.
Max door area............................Sectional door 12.0 m
2.
Motor
Type...........................................DC gearmotor permanent lubrication.
Noise level.................................54 db at 1 metre.
Drive Mechanism
Drive ..........................................Belt with one-piece trolley on steel rail.
Length of Travel.........................Adjustable to 3.0 m.
LED light ....................................25 Watt equivalent.
Door Linkage .............................Adjustable door arm. Pull cord trolley release.
Safety
Personal ....................................Push button stop in
UP and DOWN
direction. Automatic safety reverse in both
UP and DOWN
direction.
Electronic...................................Automatic force adjustment.
Electrical ....................................Transformer overload protector and low voltage push button wiring.
Limit Device...............................Mechanical Passpoint/RPM sensor.
Limit Adjustment ........................Electronic.
Soft-start/Soft-stop
Dimensions
Length (Overall).........................3.24 m.
Headroom Required.................. 30 mm.
Hanging Weight.........................11 kg.
Receiver
Memory Registers .....................64 handset codes.
4 keypad devices - 1 code each.
Operating
Frequency...................................433.30/433.92/434.54 MHz.
SPECIFICATIONS - SECTIONALLIFT - CS65MYQ
35