Initial System Setup
Page 5 of 8
Doc 6001050, Rev E
Initial System Setup
Setting the Entry Code Length
If you decide to change the entry code length
after
the initial programming, you will need to delete all of the
entry codes before changing the code length. Once you change the entry code length, the old codes will no
longer be valid and cannot be deleted
.
Factory Setting:
4 digits
1.
2. New Entry Code Length (4 or 5)
3.
Example:
8 + 5 + #
Changes entry code length to “5” maximum digits.
Setting the Relay Activation Time
This tells the system how long to activate the relay that unlocks/opens your door or gate.
Factory Setting:
10 seconds
1.
for the Main Relay OR
for the Auxiliary Relay
2. Number of Seconds (2-255)
3.
Example:
1 + 15 + #
Sets the main relay’s activation time to “15” seconds.
Note:
If this relay activates a gate operator with a momentary contact closure, set the relay activation
time for a short period (for example, 2 seconds). A longer activation time might cause the gate to
repeatedly open and close until the activation period has expired.
Setting the Maximum Number of Keypad Errors (Strikes and Out)
This feature prohibits unauthorized persons from guessing an entry code. Anyone entering an entry code will
have a set number of times to correctly enter his/her code. Each time the code is entered erroneously, it is a
“strike”. After
x
number of “strikes”, the system will disallow keypad entries at the unit for 3 minutes.
Factory Setting:
5
1.
2. Maximum Number of Errors Allowed (0-10; 0 = Disable)
3.
Example:
3 + 3 + #
Changes the maximum number of keypad errors to “3”.