background image

1

CONTR

OLLER BO

ARD

GL

MODELS SW490 1/2 HP & 3/4 HP ARE FOR VEHICULAR 
PASSAGE GATES ONLY AND ARE NOT INTENDED FOR 
PEDESTRIAN PASSAGE GATE USE.

For use with SW490 1/2 HP & 3/4 HP Gate Operator's ONLY.

Refer to owner's manual for complete installation instructions.

ADDENDUM

Models SW490 1/2 HP & 3/4 HP

Summary of Contents for LiftMaster Professional SW490

Page 1: ...4 HP ARE FOR VEHICULAR PASSAGE GATES ONLY AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE For use with SW490 1 2 HP 3 4 HP Gate Operator s ONLY Refer to owner s manual for complete installation instructions ADDENDUM Models SW490 1 2 HP 3 4 HP ...

Page 2: ...r 115 230V TEFC 3PH 1 2 HP 20 3075B 4T Motor 230 460V TEFC 3PH 3 4 HP 20 3050B 5T Motor 575V TEFC 3PH 1 2 HP INDIVIDUAL PARTS 10 18458 Side Plate Cover 10 2013 Mounting Bracket 73 18457 Frame Assembly 10 G0326 Switch Box Cover 23 3001 On Off Switch 20A 23 3005 On Off Switch 3PH 76 G0564 Alarm assembly K001A5566 Control Board GL 12 2002 Bearing 1 1 2 x1 3 4 NOTE All parts are specific to model of g...

Page 3: ...9024 Master Link 50 G232016 Limit Switch 32 2001 Gear Reducer 75 G0400 Single Swing Collar 75 G0401 Double Swing Collar K74 18382 Hall Effect Sensor Assembly 80 207 19 Key 1 4x1 4x1 1 2 80 207 23 Key 3 16x1 3 8 80 207 25 Key 3 8x3 8x2 1 4 03 8024 K Mini Contactor 24V 24 115 1 Relay 115 Vac 24 230 5 Relay 208 230V 21 3260 1 Transformer 60V VARIABLE PARTS OVERLOAD 25 2006 6 Amp Overload Fuse 25 2010...

Page 4: ... NOTE 5 115 ONLY SEE NOTE 5 SEE NOTE 2 SEE NOTE 1 PRIMARY 230V ONLY J2 PLUG J2 PLUG 24 Vdc SOFT OPEN B LIMIT A LIMIT CONTACTOR B CONTACTOR A RPM SENSOR RPM IN RPM GND RPM SUPPLY RADIO COMMAND SHADOW CLOSE STOP SOFT OPEN HARD OPEN INT LOOP OBS OPEN OBS CLOSE DC GND LOCK 1 LOCK 2 ALARM 1 ALARM 1 ALARM ASSY 76 G0564 24 Vac RADIO SIGNAL DUAL GATE B NC 24 Vac COMMON B LEGEND TERMINAL BLOCK J1 TERMINAL ...

Page 5: ... PHASE ONLY 845 Larch Avenue Elmhurst IL 60125 Note 1 24V Sec R R2 2 R R4 4 R R3 3 R R1 1 R R2 2 R R3 3 R R4 4 J4 1 2 24 Vac IN 24 Vac COMMON 24 Vdc SOFT OPEN B LIMIT A LIMIT CONTACTOR B CONTACTOR A RPM IN RPM GND RPM SUPPLY RADIO COMMAND SHADOW CLOSE STOP SOFT OPEN HARD OPEN INT LOOP OBS OPEN NC OBS CLOSE DC GND LOCK 1 LOCK 2 ALARM 1 ALARM 1 24 Vac COMMON GL CONTROL BOARD ALARM ASSY 76 G0564 ALAR...

Page 6: ...bove limitation may not apply to you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT OR REPLACEMENT OF BATTERIES THIS LIMIT...

Reviews: