background image

REMOVE AC AND DC POWER

1. Disconnect AC power to the operator.

2. Open operator cover.

3. Remove DC power by disconnecting the battery connection.

REMOVE EXISTING BOARD

1. Match replacement logic board dip switch settings to the

current logic board. Refer to page 7, if needed.

2. Reference page 2 for mechanical assembly details. Remove all

the ends of the wires connected to the existing board and
neatly lay them over the side of the electrical box. Leave
jumper wires located on the board connected until new logic
board wiring.

3. Remove the nylon nuts (7) holding the logic board to the

electrical box and hold for reassembly of new board.

4. Remove the screw holding the heat sink to the electrical box

and hold for reassembly of new board.

5. Remove logic board from the box, leaving the existing

standoffs in place.

INSTALL NEW BOARD

1. Install the new logic board in the electrical box using the old

standoffs. Be sure to install in the same configuration as it was
removed.

2. Secure logic board in place with the nylon nuts (7) removed in

step 3.

3. Secure the heat sink to the electrical box with the screw

removed in step 4.

NOTE:

For any additional help, refer to assembly drawing on 

page 2.

HOW TO ORDER REPAIR PARTS

OUR LARGE SERVICE ORGANIZATION SPANS AMERICA

Installation and service information

are available 6 days a week

Call our TOLL FREE number:

1-800-528-2806

Monday through Friday 5 a.m. to 6 p.m. (MST)

Saturday 7 a.m. to 7:30 p.m. (MST)

www.liftmaster.com

MODEL K79-13493-2

Logic Board

Replacement Kit

APPLICATION REQUIREMENTS:

Model FDCL operator with charge circuit board incorporating
firmware versions 06-FDCL-500.

FUNCTION:

Replacement of the logic board in an FDCL.

I N S T A L L A T I O N   I N S T R U C T I O N S

To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire, BEFORE proceeding:
• Disconnect AC power at the fuse box.
• Disconnect DC power at the battery connection.

WARNING

CAUTION

WARNING

WARNING

LOGIC BOARD WIRING

1 PHASE OPERATORS

Follow wiring directions on page 3, for additional help refer to the
wiring diagram on page 4.

3 PHASE OPERATORS

Follow wiring directions on page 5, for additional help refer to the
wiring diagram on page 6.

PROGRAM SETTINGS

Follow instructions on page 7 for optional control settings.

CONTROL CONNECTIONS

Follow instructions on page 8 for optional control settings.

1

Summary of Contents for LiftMaster PROFESSIONAL K79-13493-2

Page 1: ...to the electrical box with the screw removed in step 4 NOTE For any additional help refer to assembly drawing on page 2 HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA Installa...

Page 2: ...2 LO G I C B O A R D R E P L A C E M E N T A S S E M B LY Existing Screws New Logic Board Existing Nylon Nuts Existing Standoff...

Page 3: ...lack wire that runs from the battery negative terminal to J14 MOTOR NOTE Steps 1 and 2 affect motor run direction 1 Reconnect the original grey wire from the motor to pin where it was removed from eit...

Page 4: ...DARY PRIMARY INTERNAL THERMAL SENSOR ELECTRONIC FUSELINK ALARM INPUT 2 FACTORY JUMPER SUPPLIED YE RD BL WH BK RD BK RD WH WH BL YE BK BK YE GY PU BL BK BK WH BK BR BR BK BR BR RD BK BK BK RD WH BK RD...

Page 5: ...ICATORS 1 Reconnect the original white black wire to J2 terminal block 1 2 Reconnect the original white wire to J2 terminal block 2 3 Reconnect the low battery indicator original white wire to J2 term...

Page 6: ...CATOR REVERSING EDGE 230 460 V 3PH POWER IN GND ALARM INPUT 1 DRY CONTACT ONLY DO NOT INDUCE VOLTAGE OPEN CLOSE STOP KEY TEST COM NO SECONDARY PRIMARY INTERNAL THERMAL SENSOR ELECTRONIC FUSELINK ALARM...

Page 7: ...standard B2 wiring momentary contact to open close and stop When Fire Door Mode Type II is selected the control station is in revised C2 wiring momentary contact to open and stop constant pressure to...

Page 8: ...UTTON STATION AND SYSTEM TEST STROBE LIGHT WIRING ALARM SYSTEM NO OR NC CONTACTS 5 6 Sensing Device 11 12 NC Contacts 11 12 NO Contacts J2 J2 J2 J2 J2 Must set DIP switch 3 S1 3 to ON Must set DIP swi...