background image

The Chamberlain Group, Inc.

845 Larch Avenue

Elmhurst, Illinois 60126-1196

www.liftmaster.com

  Please read this manual and the enclosed safety materials carefully!

  Fasten the manual near the garage door after installation.

   The door WILL NOT CLOSE unless the Protector System

®

 and cable tension monitor are 

connected and properly aligned.

  Periodic checks of the garage door opener are required to ensure safe operation.

  The model number label is located behind the hinged door of your opener.

  DO NOT exceed 10 complete cycles of door operation per hour.

This product is intended for installation only by trained garage door technicians. This 
product may require adjustments to door springs and or track configurations. This product 
is not intended for use on low headroom tracks or garage doors utilizing extension springs.

For Residential and Light Duty Commercial Use

Install On Sectional Doors With Torsion 

Assemblies Only

®

C

o

m

pa

tibl

e with

Se

e Page 14 fo

r D

e

ta

il

s

Model 3800PLD

GARAGE DOOR OPENER

Summary of Contents for LiftMaster Elite Security+ 3800PLD

Page 1: ...afe operation The model number label is located behind the hinged door of your opener DO NOT exceed 10 complete cycles of door operation per hour This product is intended for installation only by trai...

Page 2: ...r Opener 26 Troubleshooting 26 27 Smart Control Panel Messages 28 Diagnostic Chart 29 PROGRAMMING 30 32 To Add or Reprogram a Hand Held Remote Control Model 895MAX 30 To Erase All Codes From Garage Do...

Page 3: ...ust extend at least 1 5 inches 2 5 12 cm past the bearing plate An electric outlet is required within 6 feet 1 8 m of the installation area If outlet does not exist contact a quali ed electrician Depe...

Page 4: ...s of door operation per hour To prevent possible SERIOUS INJURY or DEATH ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door may NO...

Page 5: ...ing Sensor Bracket 2 The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Safety Labels and Literature Hardware Acces...

Page 6: ...the collar is seated all the way on motor shaft until stop is reached Position the collar so the screws are facing out and are accessible when attached to the torsion bar Tighten the screws on both si...

Page 7: ...vehicles to avoid accidental release 6 NEVER connect door operator to power source until instructed to do so 7 NEVER wear watches rings or loose clothing while installing or servicing the garage door...

Page 8: ...e garage door opener back onto the torsion bar until pilot holes align with bracket Securely tighten collar screws to the torsion bar to 12 14 ft lbs of torque Securely tighten both set screws NOTE Yo...

Page 9: ...nsure rail surface is clean and attach lock template to track Drill holes as marked on the template Fasten power door lock to the outside of the garage door track with hardware provided Run bell wire...

Page 10: ...he wall anchors 2 and the 8 hex screws 2 provided in the hardware bag Attach the cable tension monitor to the wall using the hardware provided Make sure that the roller is on top of the cable Run bell...

Page 11: ...in place For standard installations ONLY Run bell wire up wall and across ceiling to the garage door opener Use insulated staples to secure wire in several places DO NOT pierce wire with a staple crea...

Page 12: ...the hinge and pressing up on the other end to latch into place Plug in the light to outlet NOTE Light will not operate until the garage door opener is activated Install Remote Light 1 1 1 2 2 3 3 4 4...

Page 13: ...parts 9 Reinstall the cover To avoid installation difficulties do not run the garage door opener at this time To avoid installation difficulties do not run the garage door opener at this time To redu...

Page 14: ...iling joist or wall stud 2 Attach the SPS to the support with the 1 1 2 inch lag screws 2 provided There are mounting holes on either side of the SPS 3 Connect the SPS cord into the connector on the b...

Page 15: ...gned to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such as th...

Page 16: ...ed arms facing the door Be sure there is enough clearance for the sensor beam to be unobstructed 2 If additional depth is needed an extension bracket see Accessories or wood blocks can be used 3 Use b...

Page 17: ...hite to white and white black to grey 3 4 5 7 16 11 mm HARDWARE WHT BLK Bell wire WHT Staple 1 Slide a 1 4 20x1 2 carriage bolt head into the slot on each sensor Use wing nuts to fasten safety reversi...

Page 18: ...he door is closing the door will reverse If the door is already open it will not close The remote lights will blink 10 times If bulbs are not installed 10 clicks can be heard See page 15 ALIGNING THE...

Page 19: ...he door you may toggle the door back and forth using the black and purple buttons to reach the desired closed position Push the door control or programmed remote control This sets the DOWN close limit...

Page 20: ...n and close the door fully inspect the door to ensure that it is balanced properly and is not sticking or binding If the door is not stopping exactly where you would like it repeat Program the Travel...

Page 21: ...rotector System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button to close the door The door will not move more...

Page 22: ...door to the garage door opener pull the emergency release handle straight down a second time until a click noise is heard from the garage door opener The door will reconnect on the next UP or DOWN ope...

Page 23: ...and one Security Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your garage door opener with any...

Page 24: ...c Light Feature The garage door opener light will turn on automatically when a person enters the garage When a person walks in front of the door control the light will come on for ve minutes then shut...

Page 25: ...ontrols gate operators or access control systems Press and hold the button down until the door or gate starts to move The remote control will operate from up to 3 car lengths away on typical installat...

Page 26: ...connection at the door control a short under the staples or a broken wire Are the wiring connections correct Review Installation Step 5 page 11 The door operates from the Door Control but not from th...

Page 27: ...Open and close the door manually A properly balanced door will stay in any point of travel while being supported entirely by its springs If it does not disconnect the garage door opener and call a tr...

Page 28: ...message will appear when the learn button has been pressed a second time on the door control or anytime on the garage door opener The garage door opener is ready to program another remote control by s...

Page 29: ...nd secure brackets Verify door track is rmly secured to wall and does not move SYMPTOM Door travels 2 3 inches and stops Reprogram limits and forces See Adjustment section If the motor unit continues...

Page 30: ...e remote control turn on Press and release the Learn button on the garage door opener The Learn LED will light Within 30 seconds Press and release the Prog Learn button on the Smart Control Panel twic...

Page 31: ...en press ENTER The door should move To set a temporary PIN You may authorize access by visitors or service people with a temporary 4 digit PIN After a programmed number of hours or number of accesses...

Page 32: ...the garage door opener using the hand held remote door control or keyless entry The code has been learned when the remote light comes on Your garage door opener remote light has already been programme...

Page 33: ...41A6104 Cable tension monitor 8 41C0902 Mounting bracket 9 41A5034 Safety sensor kit receiving and sending eyes with 3 feet 9 m 2 conductor bell wire attached KEY PART NO NO DESCRIPTION 10 41A6388 Col...

Page 34: ...pener Assembly Parts 3 2 6 5 4 1 KEY PART NO NO DESCRIPTION 1 41DJ001 Logic board complete with plate 2 41A6408 Travel Module 3 41C168 Transformer KEY PART NO NO DESCRIPTION 4 41A6095 Motor with brack...

Page 35: ...closed Monitors up to 4 garage doors by adding additional sensor modules 915LM Garage Door Monitor Sensor Additional accessory sensor for homes with multiple garage doors 916LM EverCharge Standby Pow...

Page 36: ...confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replace...

Reviews: