Page 18
Wiring a RF Module / Card Reader / Keypad
Wiring a Radio Frequency Module
An optional
radio frequency module
and a remote antenna can be installed if
the residents will access a
controlled area with a transmitter.
Refer to instructions supplied with the optional
RF Module
for more
information.
Wiegand Card Reader/Keypad
Wiegand card readers and keypads can be connected to either of
2 optional Wiegand modules
that can be placed
in the unit.
Each Wiegand module supports two card readers/keypads.
Some Wiegand card reader/keypads have
a sixth blue wire. DO NOT connect this blue wire to the unit. Insulate this wire from the unit to prevent a short
(Refer to instructions supplied with your Wiegand device for more information).
RG-6
Coaxial
Connector
RG-6 Coaxial Cable
100 Feet Maximum
Remote Antenna
Avoid any metallic
surface around the
antenna.
RF Module(s) will fit in positions
J400
(
Device 1)
and/or
J407
(
Device 3)
(4 Mounting Screws per Board are Required)
1 RF Module Kit
Part # RFMODKT
(390 MHz)
or
Part # RFMODKT3
(315 MHz)
J407 Position
J400 Position
Card Reader is Wired to
Device 1
P12V
P5V
DATA 0
DATA 1
LED
COM
P12V
P5V
DATA 0
DATA 1
LED
COM
J1
J2
J1
J2
Device 1
Device 3
Device 2
Device 4
Red Power
Green
White
Brown
Black
Shield
(Attach to the
unit ground only).
Blue
(Insulate this wire).
Use 18-24
AWG
1 Wiegand Module Kit
Part # WOMODKT
P12V
P5V
DATA 0
DATA 1
LED
COM
P12V
P5V
DATA 0
DATA 1
LED
COM
Wiegand Modules will fit in
J400
as
Device 1
(J1) and
2
(J2)
and/or
J407
as
Device 3
(J1) and
4
(J2)
(4 Mounting Screws per Board are Required)
NOTE:
The remote can control 1-4 doors.