![Chamberlain LiftMaster CPT1 Installation And Operation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/chamberlain/liftmaster-cpt1/liftmaster-cpt1_installation-and-operation-instructions-manual_2587777004.webp)
Doc 6001535, Rev G
Page 4 of 6
Installation and Wiring
PARTS SUPPLIED
Wiegand Receiver
Antenna
Installation and Operation Instructions
PARTS
NOT
SUPPLIED
# 6 Mounting Hardware
5-conductor shielded cable; 22 AWG wire
Extension Kit (Optional)
STEP 1: MOUNT THE RECEIVER
Mount receiver to surface using #6 hardware (not
supplied). Refer to Figure 8 for receiver mounting
hole locations.
NOTE:
Mount receiver with 18” of space above
the receiver for the antenna. Also, receivers
should be installed at least 5 feet apart to
avoid “cross-talk”.
STEP 2: CONNECT THE ANTENNA
Screw on antenna clockwise and slide rubber boot
down to meet o-ring (see Figure 7).
CAUTION
The outside of the antenna connector is not
ground. If using an extension kit, do not allow it
to contact a metal object.
1535F5
Figure 7: Antenna Attachment
STEP 3: CONNECT SIGNAL/POWER WIRES
Remove the terminal block from J2 on the circuit
board. Connect wires from the CPWR 6-pin
connector to the access control system. Refer to
Figure 8. Then re-insert the terminal block onto J2.
Wire the CPWR to the access control systems’
card reader
port. Refer to the access control
system’s installation instructions for appropriate
wiring detail. A
typical
wire connection might
resemble the following:
CABLE SIGNALS
WIRE COLOR
LED BROWN
DATA 1
WHITE
DATA 0
GREEN
+12VDC RED
COMMON (GND)
BLACK
SHIELD SHIELD
NOTE:
At power up, the CPWR will perform a
system check and produce a series of LED
flash sequences. This is normal.
Mounting Holes
(4 Corners)
J2
To Access Control
Circuit Board (Reader Port)
1535F4
Figure 8: Signal and Power Connections