Chamberlain LiftMaster CB202EV Instruction Download Page 16

FAQs

Pressing P1, P2 and P3 does not show any reaction

The gate opener doesn’t respond at all; no LED is
on.

Immediately after the gate has started moving, it
stops and reverses.

Gate can only be opened


Timer to close” doesn’t work.

The control board does not work any more using
the transmitter, only with the switch and even then
only as long as a button is pressed and kept
pressed.

The gate opener doesn’t respond at all, although
the controller has been connected (LEDs are on).

Control board does not work with transmitter

Control board does not work

Gate doesn’t open completely

Travel distance can’t be programmed

The operator sometimes movess slowly

Limit switches OPEN and CLOSED nicht correctly
indicated

Gate opens instead of closing automatically
(Timer to close activated)

The remote control’s range is too short.

The gate must follow a slope.

Possibly power failure.

Obstacle in area of gate.
Gate rough running (consult dealer)

photocell blocks

Photocell, a safety edge or the emergency
stop disables the control board
Only one photocell was connected for OPEN

1. Remote control not programmed.
2. LEDs indicate a fault.
3. Photocell connected incorrectly.
4. Motor terminal possibly not connected
properly.

1. transmitter not programmed
2. photocells block
3. DIP “RADIO PROGRAM” is on

travel distance not programmed

Gate heavy / rough running

1. DIP setting not correct
2. see Diagnostic LED
3. interferences in wiring of photocells, switch
or safety edge
4. Gate moves for 1 second only and stops
without reversal during programming
5. Magnetic limit switch

Powerfailure

incorrect programming

incorrect programming

DIP “RADIO PROGRAM” must be off

1. Check conductor and zero conductor.
2. Check house fusing.

Check gate area for objects
check photocells
reprogram travel distance

Function and connection must be
checked

Only works if the 2-cable photocell 771E(ML)
or 772E(ML) installed.

At least 1 pair of photocells active in
OPEN or CLOSED must be connected

1. Programming remote control.
2. Find and rectify fault(s) (see description of
diagnostic LEDs).
3. Check photocell connection / programming.
4. Check terminals and connections.

1.Program transmitter
2.Check photocells, check diagnostic LEDs
3. DIP “RADIO PROGRAM” must be off.

Program travel distance. See initial
operation / diagnosis LED

re-program travel distance
consult dealer/specialist

1: follow the instruction of “Initial Operation”
closely
3: remove for checking, then re-program
travel distance
4: check RPM sensor/Encoder on control
board
5: install magnetic limit switch properly

Common procedure. After powerfailure the
operator performs a selftest. Depending on
the operator model this can take a few
seconds or a complete cycle. Do not interrupt
this test via remote control or switch,
otherwise the limits may change. If this is the
case reprogram travel distance using P1.

During programming the limit switch OPEN
must be reached using P1, then limit switch
CLOSED. Switching motor cables is not
required.

repeat programming as described in these
instructions

 

       14/14 en

The installation of an external antenna is recommended as the controller with the short cable
antenna is located either behind the post or near ground level in most cases. The optimum
location of the antenna is as high as possible in all cases. An appropriate antenna with
installation kit can be obtained as an accessory.

Not recommended! Change gate! The gate can move in an uncontrolled (dangerous) manner if
the gate opener has been released. A stronger force is needed in the upwards direction of the
slope and then, in the opposite direction, the gate opener’s force is too strong.

Summary of Contents for LiftMaster CB202EV

Page 1: ... RADIO MODULE RADIO MODULE CB202EV Instruction ...

Page 2: ...F PUSH BUTTONS P1 P2 P3 RESET 5 RADIO TRANSMITTERS 6 FLASHING LAMP 6 KEYSWITCH 6 STOP SWITCH 6 SAFETY EDGE 6 CONTACT EDGE 6 SAFETY ACCESSORY KIT myQ DOOR MONITOR 6 PHOTOCELLS 7 RADIO AND RADIO PROGRAMMING 7 PROGRAM INTERNET GATEWAY DOOR MONITOR 8 LOOP DETECTOR 9 DIP SWITCH SETTINGS 9 INITIAL OPERATION BASIC SETTING 10 12 TIMER TO CLOSE AUTO CLOSE 12 FORCE TORQUE OF MOTOR 12 DISPOSAL 12 BATTERY DIS...

Page 3: ...with your gate manufacturer for an opener installation reinforcement kit Activate opener only when the gate is in full view free of obstructions Do not allow children to play near the gate Humidity and water destroy the control board Make sure under all circumstances that water humidity or dammed up water cannot penetrate the control board covering Frequently examine the installation for imba lanc...

Page 4: ...st be mounted at a height of up to 2 5m INSTALLATION OF CONTROL BOARD The CB202EV control board was designed for installation in a special covering under the housing of the sliding gate drive The installation of the control board is allowed only after the completion of the mechanical installation All work on the control board must be performed after disconnecting it from the mains Turn on the powe...

Page 5: ...nd armoured or suitably protected You may also consult your local electrician Terminals The terminal blocks on the controller can be removed pull to facilitate a convenient wiring and are pushed back only while installing the controller Even if a terminal strip is not in use it must be pushed back The wiring is done as described in the wiring diagram Plugs available on the motor and the transforme...

Page 6: ...d functions required for safe operation The electronics provides an ideal and matching closing force When installed and adjusted correctly the gate can be stopped manually During operation the gate can be stopped via remote control push button or key switch The gate requires a firm stop for OPEN and CLOSED position Humidity and water destroy the control board Make sure under all circumstances that...

Page 7: ...ic also refer to page 13 LEARN yellow Programming indicator ON flashing programming is active OFF off CH1 red Remote control programming for complete opening ON New remote can be programmed OFF off CH2 red Remote control programming for partial opening Refer to CH1 DESCRIPTION OF PUSH BUTTONS P1 P2 P3 RESET P1 P2 P3 P1 P1 P1 P2 P2 P3 P3 DIP RADIO PROGRAM P1 DIP RADIO PROGRAM P2 RESET Limit setting...

Page 8: ...rking according to the 8 2 kilo ohm principle can be connected to the control board Terminals Stop 8 2 kOhm i e a 8 2 kilo ohm test resistor is attached to the end of the safety edge It ensures that the electric circuit is monitored permanently The control board is supplied with an 8 2 kilo ohm resistor installed Several safety PHOTOCELLS OPTIONAL MODELS 771E 772E The use of photocells is recommen...

Page 9: ...te to open Connection between 2 COM adjustable DIP PHO 2 MODE is off active when gate is closing DIP PHO 2 MODE is on active when gate is opening RADIO AND RADIO PROGRAMMING PROGRAM DELETE REMOTE CONTROLS The receiver has two channels CH1 and CH2 The respective LEDs CH1 and CH2 are assigned to these two channels Receiving a signal from a programmed remote control button CH1 fully opens the gate Re...

Page 10: ...hing the LEDs will blink 3 times and go out 7 The App will tell you if programming was successful and will prompt you to assign a name to the gate PROGRAM DOOR MONITOR Using the RESET Button on the control board 1 Connect power to the door monitor Position the door monitor in a convenient visible place inside the house If this place is too far from the gate opener the connection may not be possibl...

Page 11: ...topped When used for a safety edge the gate reverses for aproximately 20 cm OFF Factory setting is 8 2KOhm Safety edge or 8 2kOhm resistor is required ON Emergency stop required In this case the resistor must be removed and replaced by the switch or a switch circuit OPEN PED Defines if a key switch opens the gate completely or partially Note If the DIP OPEN PED is on and timer to close is activate...

Page 12: ...E and engage gate opener 2 Press buttons P1 P2 and P3 at the same time for about 2 3 sec LED LEARN starts to flash 3 Now watch the gate The gate can be moved in both directions using the button P1 Press the button P1 several times 1 2 seconds each time to understand the function of the button If none of the buttons are pressed for about 15 seconds the control switches back to normal operation Repe...

Page 13: ...rnative PROGRAMMING THE DISTANCE ADVANCED INDIVIDUAL Note The button P1 must be pressed several times in this program With each press of the button the position at which the soft stop slow speed starts is saved Long or short soft stop settings are possible 1 Gate is closed gate position is Close Limit LED CLOSE LIM glows 2 Press P1 and P2 simultaneously for a longer time about 5 6 seconds until th...

Page 14: ...ly while programming the travel distance Thrust can only be modified by programming the travel distance again If gate movement is impeded by weather or changes to the installation rust or inappropriate lubrication it may have to be repaired The control board complies with the latest EU guidelines One of these guidelines specifies that the closing forces at the gate edge must not exceed 400N 40 kg ...

Page 15: ...damaged wire in powercable C Back up battery optional accessory empty EEPROM Fault Power up failed Defect on relay or major electrical component A Overload B Bad wiring wrong C water in photocells bad installation D a photocell was connected before but not removed disconnected Remedy Check terminals precisely Consider wire lengths Progamming travel distance failed because the gate never reached th...

Page 16: ...g Check gate area for objects check photocells reprogram travel distance Function and connection must be checked Only works if the 2 cable photocell 771E ML or 772E ML installed At least 1 pair of photocells active in OPEN or CLOSED must be connected 1 Programming remote control 2 Find and rectify fault s see description of diagnostic LEDs 3 Check photocell connection programming 4 Check terminals...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ... EG und der EG Niederspannungs Richtlinie 2006 95 EG Insbesondere wurden folgende harmonisierte Normen angewandt DIN EN 12453 Nutzungssicherheit kraftbetätigter Tore Anforderungen DIN EN 12604 Tore mechanische Aspekte Anforderungen EN 61000 6 3 Elektromagnetische Verträglichkeit EMV Teil 6 3 Fachgrundnormen Störaussendung Wohnbereich Geschäfts und Gewerbebereiche sowie Kleinbetriebe EN 60335 1 Sic...

Reviews: