background image

114A2910B-GB

9-GB

Program your Keyless Entry

Activate the opener only when door is in full view,
free of obstruction and properly adjusted. No one
should enter or leave garage while door is in
motion. Do not allow children to operate push
button(s) or remote(s). Do not allow children to
play near the door.
NOTE: 
Your new Keyless Entry must be programmed
to operate your garage door opener.
Program the Receiver to Match Additional Remote
Control Code
Using the orange “LEARN” Button:
1. Press and release the orange “learn” button (1) on

opener. The learn indicator light will glow steadily
for 30 seconds.

2. Within 30 seconds, enter a four digit personal

identification number (PIN) of your choice on the
keypad (2), then press and hold the ENTER
button.

3. Release the button when the opener light blinks

(3). It has learned the code. If the light bulb is not
installed, two clicks will be heard.

Using the Multi-Function Door Control:
NOTE: 
This method requires two people if the
Keyless Entry is already mounted outside the garage.
4. Enter a four digit personal identification number

(PIN) of your choice on the keypad, then press
and hold ENTER.

5. While holding the ENTER button, press and hold

the LIGHT button on the Multi-Function Door
Control.

6. Continue holding the ENTER and LIGHT buttons

while you press the push bar on the Multi-Function
Door Control (all three buttons are held).

7. Release buttons when the opener light blinks. It

has learned the code. If the light bulb is not
installed, two clicks will be heard.

1

2

3

4

LOCK

LIGHT

5

LOCK

LIGHT

6

LOCK

LIGHT

1

3

2

60 s

120 s

180 s

O

24

Using the Wall-Mounted Door Control

THE MULTI-FUNCTION DOOR CONTROL
Press the push bar (1) to open or close the door.
Press again to stop the door.
Light feature
Press the light button to turn the opener light on or off.
It will not control the opener lights when the door is in
motion. If you turn it on and then activate the opener,
the light will remain on for 2 1/2 minutes. Press again
to turn it off sooner. The 2 1/2 minute interval can be
changed to 1-1/2, 3-1/2  or 4-1/2 minutes as follows:
Press and hold the Lock button until the light
blinks(about 10 seconds). A single blink indicates that
the timer is reset to 1-1/2 minutes. Repeat the
procedure and the light will blink twice, resetting the
timer to 2-1/2 minutes. Repeat again for 3-1/2 minute
interval, etc., up to a maximum of four blinks and
4-1/2 minutes.
Lock feature
Designed to prevent operation of the door from hand-
held remote controls. However, the door will open and
close from the Door Control, the Outside Keylock and
the Keyless Entry Accessories.
To activate, press and hold the Lock button (3) for 2
seconds. The push bar light will flash as long as the
Lock feature is on.

To turn off, press and hold the Lock button again for
2 seconds. The push bar light will stop flashing. The
Lock feature will also turn off whenever the “LEARN”
button on the opener panel is activated.

25

1

LOCK

LIGHT

2

114A2910B-GB

10-GB

Setting the Limits

Travel limits regulate the points at which the door
will stop when moving up or down. Follow the
steps below to set the limits.
To program the travel limits:
1. Press and hold the black button (1) until the yellow

indicator light (3) starts flashing slowly and then
release.

2. Push and hold the black button (1) until the door

reaches the desired open position. Adjust the
position of the door by using the black (1) and
orange (2) buttons. Black moves the door UP,
orange moves the door DOWN.

3. Push the programmed remote control (4) or push

bar on the door control that was shipped with your
opener. This sets the full UP (open) position. The
door will travel to the floor and reverse back to the
UP (open) position. The opener has learned its
travel limits.

Check to be sure the door is high enough for your
vehicle. Adjust if necessary.
4. The indicator light (3) will stop flashing when the

limits have been learned. 

NOTE: If the door reverses before it reaches the floor

proceed to #15 of the Having a Problem? section and
follow the instructions for setting the limits manually.
The force MUST be learned in order to properly
complete the setting of the limits.

4

1

2

3

LiftM

ast

er

LiftMaste

r

2

3

1

1

3

2

60 s

120 s

180 s

O

26

ADJUSTMENT SECTION

Setting the Force

The force, as measured on the closing edge of the
door, should not exceed 400N (40kg). If the
closing force is measured to more than 400N, the
Protector System must be installed See step 29.
The force setting regulates the amount of power
required to open and close the door.
1. Locate the orange button (2).
2. Push the orange button (2) twice to enter unit into

Force Adjustment Mode. The LED (3) (indicator
light) will flash quickly.

3. Push the programmed remote control (4) or push

bar on the door control that was shipped with your
opener. The door will travel to the DOWN (close)
position. Push the remote control (4) again, the
door will travel to the UP (open) position. 

The LED (3) (indicator light) will stop flashing when
the force has been learned.
The door must travel through a complete cycle, UP
and DOWN, in order for the force to be set properly. If

the unit cannot open and close your door fully, inspect
your door to insure that it is balanced properly and is
not sticking or binding.

(2x)

4

LiftM

ast

er

LiftMaste

r

3

2

2

3

1

3

2

60 s

120 s

180 s

O

27

Test the Safety Reverse System

The safety reverse system test is important.
Garage door must reverse on contact with a
40mm obstacle laid flat on the floor. Failure to
properly adjust opener may result in serious
personal injury from a closing garage door.
Repeat test once a month and adjust as needed.
Procedure: Place a 40mm obstacle (1) laid flat on the
floor under the garage door. Operate the door in the
down direction. The door must reverse on the
obstruction. If the door stops on the obstruction,
remove obstruction and repeat Setting the Limits step
26. 
Repeat test.
When the door reverses on the 40mm obstacle,
remove the obstruction and run the opener through a
complete travel cycle. Door must not reverse in
closed position. If it does, repeat Setting the Limits

and Force steps 26 and 27 and repeat safety reverse
test.
Place 20kg at the center of the door and ensure that
the door will not move up more than 500mm.

1

28

Summary of Contents for LiftMaster 1000A

Page 1: ...uktioner Model LiftMaster 1000A 800A 600A Garageportsåbner Instrucciones Abridor de la puerta de garage Modelo LiftMaster 1000A 800A 600A O ËÁ Â MË ÓÈÛÌfi AÓÔ ÁÌ ÙÔ Î Ú fi ÔÚÙ MÔÓÙ ÏÔ LiftMaster 1000A 800A 600A F D GB DK GR E TÜV Rheinland geprüfte Sicherheit INT Int Service 49 6838 907 172 für Service 06838 907 172 for service 44 0845 602 4285 D GB F NL pour service 03 87 95 39 28 voor service 020 ...

Page 2: ...reminder of safe operating procedures Disengage all existing garage door locks to avoid damage to garage door Install the lighted door control button or any additional push buttons in a location where the garage door is visible at a height of at least 1 5m and out of the reach of children Do not allow children to operate push button s or remote control s Serious personal injury from a closing gara...

Page 3: ...ing to optimum chain tension Chain may slip off sprocket if chain belt is too loose If chain does slip re tighten spring nut by turing nut clockwise 1 2 turn Do NOT overtighten chain belt Fasten Rail to Opener and Install Chain Belt Holding chain 4 and belt 5 out of the way slide rail 1 onto shim 2 until rail is secure Take the chain belt and wrap it around the sprocket 3 Make sure the teeth on th...

Page 4: ... cut rope heat seal cut end with a match or lighter to prevent fraying 2 3 4 NOTICE 2 1 17 114A2910B GB 6 GB 4 2 4 5 5 1 3 Connect Electric Power TO AVOID INSTALLATION DIFFICULTIES DO NOT RUN THE GARAGE DOOR OPENER UNTIL INSTRUCTED TO DO SO Connect the door opener only to an outlet controlled by a double pole switch Fasten Door Bracket If you have a canopy garage door a door arm conversion kit is ...

Page 5: ...ds press and hold the button on the hand held remote that you wish to operate your garage door 2 3 Release the button when the opener light blinks It has learned the code If the light bulb is not installed two clicks will be heard 3 Using the Multi Function Door Control 1 Press and hold the button on the hand held remote that you wish to operate your garage door 4 2 While holding the remote button...

Page 6: ...its regulate the points at which the door will stop when moving up or down Follow the steps below to set the limits To program the travel limits 1 Press and hold the black button 1 until the yellow indicator light 3 starts flashing slowly and then release 2 Push and hold the black button 1 until the door reaches the desired open position Adjust the position of the door by using the black 1 and ora...

Page 7: ...2 30 Accessories 1 Model 94330E Single Function Remote Control 2 Model 94333E 3 Function Remote Control 3 Model 94335E 3 Function Mini Remote Control 4 Model 9747E Keyless Entry System 5 Model 78LM Multi Function Door Control Panel 6 Model 75E Lighted Door Control Button 7 Model 98LM Motion Detector Wall Control 8 Model 760E Outside Keylock 9 Model 1702E Outside Quick Release 10 Model 770E The Pro...

Page 8: ...elease handle Operate door manually If it is unbalanced or binding call for professional garage door service Clear any ice or snow from garage floor area where garage door closes Repeat Setting Limits and Force see adjustment steps 26 and 27 Repeat safety reverse test after adjustment is complete 6 Door reverses for no apparent reason and opener light blinks for 5 seconds after reversing Check The...

Page 9: ...ctive 89 392 EEC B P Kelkhoff Manager Regulatory Affairs Chamberlain GmbH D 66793 Saarwellingen May 2004 Input Voltage 230 240 VAC 50Hz Max Pull Force 600N LM600A 800N LM800A 1000N LM1000A Power 6Nm LM600A 8Nm LM800A 10Nm LM1000A Watts 130W LM600A 165W LM800A 190W LM1000A Standby Power 5 0W LM600A and LM800A 5 5W LM1000A Motor Type DC gearmotor permanent lubrication Drive Mechanism Drive Chain bel...

Reviews: