background image

INSTALLATION INSTRUCTIONS

APPLICATION REQUIREMENTS:

Replacement of Limit Switch and/or its components for a Model LGO Operator.

LGO Limit Switch Assy

Replacement Kit 

K74-16420

WARNING

DISCONNECT POWER AT THE FUSE BOX BEFORE

PROCEEDING. IF NECESSARY REMOVE THE OPER-

ATOR FROM ITS MOUNTED POSITION.

OPERATOR MUST BE PROPERLY GROUNDED AND

CONNECTED IN ACCORDANCE WITH LOCAL ELEC-

TRICAL CODES. NOTE: THE OPERATOR SHOULD

BE ON A SEPARATE FUSED LINE OF ADEQUATE

CAPACITY.

ALL ELECTRICAL CONNECTIONS MUST BE MADE

BY A QUALIFIED INDIVIDUAL.

NOTE:  Refer  to  the  Ownerʼs  Manual  supplied  with  the

operator for all mounting and wiring instructions.

REMOVE EXISTING LIMIT SWITCH ASSEMBLY:

Disconnect the wire connections to the limit switches.

Remove the six screws from the nut plates. Remove the limit

switches, internal grip washers and standoffs from the elec-

trical box and discard.

Remove the two 1” screws from the locknuts. Remove the

depress plate and depress plate springs and discard. 

INSTALLING NEW LIMIT ASSEMBLY:

To install the new limit assembly, follow the steps outlined

above in the reverse order.  Reconnect the wires to the new

limit switches. 

NOTE:

Other components not

shown in box for easier viewing.

NC

NO

OPEN

LIMIT

C

NC

NO

CLOSE

LIMIT

C

WIRE CONNECTIONS

(GY)

(YE)

(BR)

(YE)

(GY)

(BR)

Refer to the illustration below and for complete wiring dia-

gram see reverse side.

LGO LIMIT SWITCH ASSY

repLACeMenT KIT

K74-16420

For more information, please visit www.devancocanada.com or call toll free at 855-931-3334