![Chamberlain K001A5729 Manual Download Page 57](http://html1.mh-extra.com/html/chamberlain/k001a5729/k001a5729_manual_2587156057.webp)
57
C1
C8
C61
SLOT 1
RADIO
SLS
MR
T
M
ID
TTC
DA
T
A
24V
A
C
14
13
12
11
10
6
7
8
9
5
4
3
2
1
24V
A
C
LMEP:
EDGE:
OPEN
CLOSE
ST
OP
COMMON
RELA
Y
A
RELA
Y
B
SBC
MAS
COMMON
TIMER
DEFEA
T
POWER
TIMER
ENABLE
12
3
FSTS
DIAG
OPTN
PROG
TT
S
E2
D1
C2
B2
CLS
OLS
MID
REV
STD
SLOT 2
MOTOR
DIRECTION
3-PHASE
1-PHASE
Remove Jumper
To Install External
Door Interlock
3-Button Control Station
Maintenance
Alert LED
(RD) (WH)
Open
Close
Stop
Open/Close
Single Button
Sensing
Edge
Refer to the installation manual
for LiftMaster Monitored
Entrapment Protection (LMEP)
device connections
Hoist Interlock
When Present
TMR DEF
SWITCH
MOV
MOV
(YE)
(BL)
(YE)
(OR)
(WH)
(YE)
(PU)
(WH)
(RD)
(GY)
(YE)
(RD)
(WH)
(PU)
(YE)
(OR)
(GY)
(OR) (PU)
(WH)
(WH)
(WH)
(WH)
(WH)
(PU)
(YE)
(WH)
(WH)
(WH)
(WH)
(YE)
115 / 230
VOLT 1PH.
POWER IN
hot
neutral
ground
(BK)
COM
120
VAC
120 / 240
VAC
+24 VAC
-24 VAC
See Motor
Connections
8
0
1
4
6
2
6
2
8
4
0
1
COIL
COM
NO
C
B
A
(WH)
(BL) (GY)
(YE)
(BR)
(GY)
See Motor
Connections
NOTE:
Lock Sensor is provided on Models
DJ and DH only, red wire from main harness
connects to NC on Bypass L/S and to NO on
LOCK SENSOR Switch. White wires connect
the COM on BYPASS L/S and LOCK SENSOR
Switch to NC on Open L/S.
NOTE:
The Lock Sensor Switch is
located in the chassis.
OPEN
CLOSE
STOP
NOTE:
Gray (GY) and purple (PU) motor wires are reversed
for H and HJ right hand models and all GH and J models.
115V MOTOR CONNECTION
230V MOTOR CONNECTION
(WH)
(WH)
(WH)
(RD)
(PU)
(YE)
COM
NO
NC
NO
NC
COM
NO
NC
COM
OPEN L/S
CLOSE L/S
SAFETY L/S
(WH)
(WH)
(RD)
(YE)
(GY)
1 2 3 4
RPM Board
L3 L2 L1
External Radio Receiver
(WH)
(OR) (YE)
R1
R2
R3
F
Wiring Diagrams
Logic 4.0 - Single Phase
Summary of Contents for K001A5729
Page 1: ...For more information please visit www devancocanada com or call toll free at 855 931 3334...
Page 4: ...4 Page Basic Troubleshooting 5 SECTION A Table of Contents...
Page 7: ......
Page 33: ...33...
Page 34: ...Page Symptoms And Solutions 35 Mechanical Operators SECTION C Table of Contents...
Page 53: ...53...
Page 62: ...62 WARNING F Wiring Diagrams Mechanical Operator Single Phase...
Page 64: ......